Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 25, VQD1151 NO SIZE RATING, 0.22046 lb
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT (DC), VALVE, VQD1151 VALVE, SOL 4/5-PORT, 15, VQD1151 OTHER SIZE RATING,
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MOUNT, CLEAN ROOM, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 25, VQD1151 NO SIZE RATING, .11023
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 15, VQD1151 OTHER SIZE RATING, 0.13333 lb
-(T) . 8-7 8.4.2 HRSE018-A-10-(T) . 8-7 8.4.3 HRSE012-A-20/23-(T) . 8-7 8.4.4 HRSE018-A-20/23-(T) . 8-8 8.4.5 HRSE024-A-20/23-(T) . 8-8 8.5 Pump capacity . 8-9 8.5.1 HRSE012/018-A-10 . 8-9 8.5.2 HRSE012/018/024-A-20/23 . 8-9 8.5.3 OPTION-T (HRSE012/018-A-10-T). 8-10 8.5.4 OPTION-T (HRSE012/018/024-A-20/23-T) . 8-10 8.6 Sample DoC.
Name plate For VX21: VX021N-10 For VX22: VX022N-10 For VX23: VX023N-10 P Clip Part No. (For N.O.) For VX21: ETW-7 For VX22: ETW-8 For VX23: ETW-9 P Strainer Part No.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
Right angle, 5 m With mounting screw 2 pcs. 16-8-17 18 Series ISA2 DIN Rail ISA-5L Applicable models L 4.5 8 1.25 7.5 Part no.
Measure the amount of clean water which is dispensed 10 times continuously and convert it to one shot of dispensed volume. Repeat this measurement 10 times, and indicate the difference (%) between the average value of 10 sets of data (converted value of one shot) and the maximum and minimum values.
IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 4 to 20mADC Note 1) 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within
IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 4 to 20mADC Note 1) 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
No.IP80-OM00019-B / / * 3-4 5 1. 5 2. 6-7 2-1 IP8000 6 2-2 IP8100 7 3. 8-9 3-1 IP8000 8 3-2 IP8100 9 4. 10-12 5. 13 5-1 13 5-2 13 6. 14 7. 15-17 7-1 16 7-2 17 7-3 17 8. 18 9. 18-20 10. 20-22 11. 23-25 11-1 23 11-2 IP8100 23 11-3 IP8000 24 11-4 24 11-5 25 12. 26 13. 27-33 2 A (ISO/IEC)(JIS)*1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic
IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action 4 to 20mADC Note 1) Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within
Bracket ZS-30-A With M3 x 5L (2 pcs.) Connector for PSE300 ZS-28-C 1 pc. A Note) The bracket is unassembled in the factory, but is included with the shipment.
Type: Manual Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 16, Seal Type: Bellows Seal, Sonic Conductance: 5L/S, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External
Type: Manual Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 16, Seal Type: Bellows Seal, Sonic Conductance: 5L/S, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External
), Number Of Switches: No switch, Seal Material: FKM 1349-80, Amount of leakage(Pa·m3/s): Internal: 1.3 × 10-10, External: 1.3 × 10-11, Body Surface Treatment: External: hard anodized aluminum, Internal: base material, Seal Change Location: None, Length of Lead Wire for Switch(m): -, Heater Yes/No: None
Series: 10 (10 Solenoid Valve Type), Thread Type: N (NPT), Voltage/ Electrical Entry: 5L (24 VDC, L plug connector w/ 300mm lead wire)