20 30 50 90 190 10 42 10 45 27 49 31 MRQ 80 190 10 35 10 62 35 66 39 65 190 10 30 10 68 39 72 43 50 190 10 24 10 83 49 87 53 Operating angle m: Value of the operating range of single auto switch (Lm) as represented by rotation angle for shaft Hysteresis angle: Value of the auto switch hysteresis as represented by angle Note) Since the above values are only provided as a guideline, they are
24 24 25 42 10 50 16 11 3/8 58 63 25 to 800 77 77 9 98 118 84 M8 x 1 9 M27 x 2 36 33 58 19 36 36 30 21 32 50 10 56 18 13 1/2 66 80 25 to 800 96 96 11 119 143 96 10.5 M33 x 2 41 32 M10 x 1.25 75 13 45 45 41 26 41 60 16 70 17 17 1/2 74 100 25 to 1000 115 115 13.5 138 162 113 14.5 M42 x 2 42 42 M14 x 1.5 90 16 56 56 50 22 52 72 16 90 22 19 3/4 86 Bore size (mm) RD S SS Y Z ZZ V 40 51 6.5 161.5
10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type weight of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C).
(mm) mm Flow rate coefficient Max. system pressure (MPa) (1) Port size Weight (g) Cv Water Air Model AC DC AC DC AC DC Effective area (mm2) 34 10 1.9 600 10 VXZ2232-02 0.7 0.6 0.7 0.6 0.7 0.6 1 4 1 4 10 43 2.4 600 10 VXZ2232-03 0.7 0.6 0.7 0.6 0.7 0.6 3 8 3 8 . 0.7 VXZ2242-04 0 1.5 15 95 5.3 850 15 0.7 0.6 0.7 0.6 0.6 1 2 1 2 165 20 9.2 1,370 20 VXZ2352-06 0.7 0.6 0.7 0.6 0.7 0.6 3 4 3 4
10 stations Size of P, EA, EB port Note) SU and TBU require one station. 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Location and size of A, B port 02 03 04 06 10 02B 03B 04B Side 1/4 Side 3/8 Side 1/2 Side 3/4 SIde 1 Bottom 1/4 Bottom 3/8 Bottom 1/2 Option Nil TBU SU W None With terminal box With SI unit Splash proof 3-11-18
Weight calculation m2 = d x e x f x Relative density m2 = 4 x 5 + 6 x 2.7 x 10-6 = 3.24 x 10-4 (kg) Inertial moment around Z2 axis IZ2 = {m2 (d2 x e2) / 12} x 10-6 IZ2 = {3.24 x 10-4 x (42 + 52) / 12} x 10-6 = 1.11 x 10-9 (kg.m2) = 1.11 x 10-9 + 3.24 x 10-4 x 23.52 x 10-6 = 0.18 x 10-6 (kg.m2) Inertial moment around Z axis IB = IZ2 x m2r22 x 10-6 IB Thus, the total inertial moment is I
10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80
B5/B64/B59W Note 1) BD1-10M CHS BA-08 BA-10 BA-05 BA-04 CH2 Note 1) The auto switches listed below cannot be mounted on 63.
Note 3) ZP3-Y(04/06/08)UM;(J/K)3-@ ZP3-Y(04/06/08)B;(J/K)3-@ ZP3-Y(04/06/08)UM;(J/K)6-@ ZP3-Y(04/06/08)B;(J/K)6-@ ZP3-Y(04/06/08)UM;(J/K)10-@ ZP3-Y(04/06/08)B;(J/K)10-@ ZP3-Y(04/06/08)UM;(JB/K)15-@ ZP3-Y(04/06/08)B;(JB/K)15-@ ZP3-Y(04/06/08)UM;(JB/K)20-@ ZP3-Y(04/06/08)B;(JB/K)20-@ ZP3B-Y2B(J/K)6-B5 ZP3B-Y2B(J/K)10-B5 ZP3B-Y2B(JB/K)15-B5 ZP3B-Y2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08
10 12 12 16 16 26 30 36 42 48 54 64 78 19 19 30 30 38 38 60 60 5 5 6 6 10 10 12 12 51 58 68 82 100 108 139 153 8 8 10 10 12 12 16 16 18 22 24 30 34 40 46 58 7 7 9 9 9 9 10 10 13 15 18 21 24 27 32 39 6 8 10 13 16 16 20 20 13 15 18 21 24 27 32 39 29 33 37 37.5 37.5 44 44 49 8 10 12 16 20 20 25 25 7.5 8 8.5 9 9 10 11 13.5 M4 M4 M5 M5 M6 M6 M8 M10 90 42 46 53 53.5 59.5 66 72 77 6 8 10 12 16
Width across flat Effective area (mm2) Weight (g) L M d Model 2 x Applicable tubing H1 H2 I.D. 2.5 3 4 6 7.5 8 9 10 13 H1 H2 H2 4 4 6 8 10 10 12 12 16 KFG2H0425-00 KFG2H0403-00 KFG2H0604-00 KFG2H0806-00 KFG2H1075-00 KFG2H1008-00 KFG2H1209-00 KFG2H1210-00 KFG2H1613-00 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 7 11 25 43 42 44 42 71 1.6 2.6 6 17 30 35 45 57 101 8 8 21.8 5 d 10 14 10 14 24.8 28.6 5.8 6.6
Material Description Part number No. 4 5 10 NBR Gasket VVQ5000-80A-1 Type 10 NBR Gasket VVQ5000-80A-2 Option A 1 station Note) Spare parts consist of sets containing 10 pcs. each.
, 06, 07 01, 23, 03, 04, 06, 07 AS-F 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 TMH 400 200 06, 07 02 01, 23 ASD 300 50 03, 04 100 200 AS 01, 23 100 AS-FE 0 0 0 KE 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations AS-FG AS-FG Note) -U10/32 has the same specification as M5
Part no. 0.1 0.3 +0.070 0 12 I-04 I-05 I-08 I-10 40 50, 63 80 100 NT-04 NT-05 NT-08 NT-10 40 50, 63 80 100 16 15.5 20 69 22 24 55 M14 x 1.5 M14 x 1.5 8 22 25.4 21 0.1 0.3 +0.070 0 12 74 27 28 15.5 20 11 60 M18 x 1.5 M18 x 1.5 27 31.2 26 16 0.1 0.3 +0.070 0 18 36 22.5 26 91 37 71 M22 x 1.5 M22 x 1.5 13 32 37.0 31 28 0.1 0.3 +0.084 0 20 28 37 40 24.5 105 83 M26 x 1.5 M26 x 1.5 16 41 47.3 39
Part no. 0.1 0.3 +0.070 0 12 I-04 I-05 I-08 I-10 40 50, 63 80 100 NT-04 NT-05 NT-08 NT-10 40 50, 63 80 100 16 15.5 20 69 22 24 55 M14 x 1.5 M14 x 1.5 8 22 25.4 21 0.1 0.3 +0.070 0 12 74 27 28 15.5 20 11 60 M18 x 1.5 M18 x 1.5 27 31.2 26 16 0.1 0.3 +0.070 0 18 36 22.5 26 91 37 71 M22 x 1.5 M22 x 1.5 13 32 37.0 31 28 0.1 0.3 +0.084 0 20 28 37 40 24.5 105 83 M26 x 1.5 M26 x 1.5 16 41 47.3 39
Type Pneumatic 1 MPa Max. operating pressure 0.1 MPa Min. operating pressure Specifications Mountable Auto switch Pneumatic Type Refer to pages 11-7-10 to 11-7-12 for dimensions.
Type Pneumatic 1 MPa Max. operating pressure 0.1 MPa Min. operating pressure Specifications Mountable Auto switch Pneumatic Type Refer to pages 11-7-10 to 11-7-12 for dimensions.
10 12 12 16 20 d7 11 11 13 13 16 19 l3 10 10 10 10 12 14 Bore Model Thread e M4 x 0.7 M4 x 0.7 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.25 b d 16 16 24 24 32 40 0 8 10 12 16 20 25 8 10 12 16 20 25 KJ4D KJ4D KJ6D KJ6D KJ8D KJ10D GKM4-8 GKM4-8 GKM6-12 GKM6-12 GKM8-16 GKM10-20 8 8 12 12 16 20 6 6 8 8 10 12 8 8 12 12 16 20 8 8 10 10 12 18 5 5 6 6 8 10 4 4 6 6 8 10 6.0 8 8 9 9 12 14 7.5 7.5 6.5 6.5 13
) 06 (10) Y610(03) 04 (03) 04 Y610Note 5) Note 6) VHS40-06 02 03 04 E600VHS2001 02 02 03 02 03 VHS30VHS30VHS40VHS50Note 6) E30002 03 04 E30002 03 04 E40002 03 04 06 E500-06 E20001 02 03 Note 6) 06 10 06 10 E60006 10 E600E100-M5 02 03 04 06 IS1000E-30 IS1000E-30 02 03 04 IS1000E-20 01 02 03 Note 6) Pressure switch with piping adapter 02 03 04 IS1000E-40 Note 6) Y24-01 02 Y34-01 02 Y34-01 02
9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018