SMC Corporation of America
Elite Part Number Search
Search Results "VXR2260-10N-1C"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VEX PROPORTIONAL VALVE, 1A, VEX, 2.50800 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, POWER VALVE, VALVE, VEX PROPORTIONAL VALVE, 1A, VEX, 3.08647 lb

Power valve series VEX includes a regulator valve (VEX1*0), precision regulator (VEX1*3), 3 position valve (VEX3) and a economy valve (VEX5). The 3 port large capacity poppet exhausting regulator is equipped with a relief port the same size as the connection port. The 3-port, 3-position double solenoid that permits vacuum suction, vacuum destruction, and suspension (closed) is ideal for

Power valve series VEX includes a regulator valve (VEX1*0), precision regulator (VEX1*3), 3 position valve (VEX3) and a economy valve (VEX5). The 3 port large capacity poppet exhausting regulator is equipped with a relief port the same size as the connection port. The 3-port, 3-position double solenoid that permits vacuum suction, vacuum destruction, and suspension (closed) is ideal for

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, POWER VALVE, VALVE, VEX PROPORTIONAL VALVE, 1F, VEX, 4.62000 lb, ModelBracketGrommetGrommet terminalConduit terminalDIN terminal ab?cdefghijVEX370120136920549156.5182195207

Power valve series VEX includes a regulator valve (VEX1*0), precision regulator (VEX1*3), 3 position valve (VEX3) and a economy valve (VEX5). The 3 port large capacity poppet exhausting regulator is equipped with a relief port the same size as the connection port. The 3-port, 3-position double solenoid that permits vacuum suction, vacuum destruction, and suspension (closed) is ideal for

SMC has developed the VXE series energy saving type, 2 port solenoid valve to help with environmental issues.  The PWM (Pulse Width Modulation) method was used to allow for less power consumption.  By reducing the energy consumption we have also reduced the heat produced by the coil. This series is available in three styles VXE directed operated, VXED pilot operated, and VXEZ zero differential

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, EA, VXP/VXR/VXF BODY PORT 1/4 NPT, 1.20274 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP21AC5020 (32)114.545

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, LA, VXP/VXR/VXF BODY PORT 3/4 PT, 2.89751 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP21AC5020 (32)114.545

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1B, VXP/VXR/VXF, 16.13049 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP23AC5050211165

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1B, VXP/VXR/VXF, 16.38768 lb, ModelPower sourceFrequency (Hz)Apparent power (VA)Power consumption (W) (Holding)Temperature rise (C)(Rated voltage) InrushHoldingVXP23AC5050211165

The air-hydro unit consists of a converter and a valve unit that are compactly integrated. It converts air pressure to an equivalent hydraulic pressure, and this hydraulic pressure is used for operating an actuator, thus solving the problem that is associated with the compression characteristics of air. Thus, in spite of using pneumatic equipment, it performs similarly to a hydraulic unit

The air-hydro unit consists of a converter and a valve unit that are compactly integrated. It converts air pressure to an equivalent hydraulic pressure, and this hydraulic pressure is used for operating an actuator, thus solving the problem that is associated with the compression characteristics of air. Thus, in spite of using pneumatic equipment, it performs similarly to a hydraulic unit

For applications requiring micro-mist separation up to 0.1µm with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK, VALVE, VV5Q41 NO SIZE RATING, 1.76369 lb

Series VXP pilot operated 2 port solenoid valve for air, gas, steam, water and oil. Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., VALVE, MEDIA, VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 4.20152 lb, ModelPower sourceFrequency (Hz

MANIFOLD BLOCK, VALVE, VV5Q41 MFLD, VQ4000 4/5-PORT, 21, VV5Q41 NO SIZE RATING, 1.43161 lb

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal