Allowable Kinetic Energy + With Rubber Bumper Non-rotating accuracy when retracted and when no load is applied should be not more than the values shown in the table. 1000 Bore size Non-rotating accuracy q 12 (10 x 2) 0.07 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 0.06 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 0.05 63 (45 x 2) 80 (56 x 2) 0.04 100 (71 x 2) 100 (71 x 2) 80 (56 x 2) 63 (45 x 2) 100 50

2) 10 16 (12 x 2) 12 (10 x 2) 1 0 50 100 150 200 250 300 350 Maximum speed [mm/sec] 5 Compact Guide Cylinder JMGP Series Bore Size 12 (10 x 2), 16 (12 x 2) Standard: JMGPM WA + Stroke/2 Z X 4 x YY depth YL Bottom view WA + Stroke/2 Z 4 x OA through 4 x OB counterbore depth OL 4 x MM depth ML L 2 x P (Plug) (OL) 4 x NN through PW X U H VA PE T R 2 x P (Plug) 2 x P D 2 x P (Plug) GB GA S Q

Red ON Short circuit at L+ or C/Q LED 1, 2, 3, 4 for I/Q (EX600-LAB1) Function LED status Description End plate bracket (EX600-ZMA2) OFF Input OFF I/Q Orange ON Input ON CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

CHKDB CHKGB Double acting, Single rod 40 10 16 CX 50 5, 10, 15, 20, 25, 30 35, 40, 45, 50, 75 100 63 CY 80 100 MQQ M CHKDB CHKGB RHC MK(2) RS Q G RS H A For details, refer to the catalog CAT. E111.

How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Water and Air Safety

How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17

KPGU12-00 KPQU12-00 24 20.9 32 58 46 20.9 18.1 55.2 31.9 Q Note 1) D indicates the maximum diameter.

RS Q G Valve A If the converter is positioned lower than the cylinder: RS H A Drain port (Piping port) After filling with oil as described in step 4 above, close the oil filler plug. Then, introduce air pressure of approximately 0.05 MPa into the converters air port to push the oil into the cylinder.

2 x RA 2 x 2 x OA CQS Both ends tapped (CQMA) CQ2 RQ (mm) CQM Without auto switch With auto switch Bore size (mm) Stroke range (mm) P P EA EB EC MU A B F Q A B F Q TN TF TN TF 5 5.5 11.5 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc 1/8 NPT 1/8 G 1/8 7.5 10.5 G 1/8 Rc 1/8 NPT 1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc 1/8 NPT 1/8 G 1/8 8 11 G 1/8 56.5 39.5 8 11 52 50 41.4 Rc

MHS2-32D MHS2-40D Q 11 12 RA 38 44 SA 4.5 5.5 FX 23 26.5 G 30.5 32 AA 44 47 NA 14 16 J 20 21 AB 41 44 L 2H9 3H9 B 56 62 DO 64 70 DC 56 62 EO 24 28 EC 16 20 CA 8 9 CB 16 17 FY 20.5 23.5 FZ 5 6 +0.025 0 +0.025 0 Model MHS2-32D MHS2-40D UA M5 x 0.8 M6 x 1 UB 10 12 VA VB 3 4 WA XA XB 3 4 SB 8 9.5 +0.025 0 +0.030 0 +0.025 0 +0.030 0 +0.062 0 +0.062 0 34H9 3H9 4H9 3H9 4H9 42H9 6 Series MHS 2

with a push button guard: KEB Release time S Release time of pressure in the cylinder Body (Red) Residual pressure release push button (Red) VCHC D With One-touch fitting without a push button guard Release button (Blue) Release button (Blue) ASR ASQ D L1 Q B A D 8 4.2 Applicable tubing W (mm) M M L2 L2 Applicable tubing Weight (g) Model Applicable tubing O.D. 6 8 10 12 D L1 L2 Q W M KEB06

D 1 5 CE-compliant Nil None Q CE-compliant Clean series Manifold type 2 Body ported 5 Base mounted Valve stations 02 2 stations Port size Nil Body ported M5 thread M5 Base mounted M5 thread C4 Base mounted 4 One-touch fitting 20 20 stations (Maximum) How to Order Valve [Option] 10 V Q D 1 1 5 1 5 L M5 Clean series Body type 3 Body ported 5 Base mounted Valve option Nil Standard

Designation Content 1 L+ +24 V for logic/input 2 P24 +24 V for output 3 L0 V for logic/input 4 C/Q IO-Link communication data 5 N24 0 V for output Fig 2-1. Pin allocation of M12 5 pins plug A-coded connector The power supply for logic/input and the power supply for output are isolated. 2.2.

Preset mode RS Q G 2. Setting of preset mode RS H A (1) Selection of preset No. PRESET RZQ Select a preset number from 1 to 31 with the UP/DOWN keys. Shift to the next item with the SEL. key. NO.

Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only

Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, SPL, VALVE, SS5Q2 MANIFOLD SQ2000, 2N, SS5Q2 NO SIZE RATING, 4.40924 lb

flow rate (l/min) Q: flow rate (l/min) Q: flow rate (l/min) Q: flow rate (l/min) d: int d: int d: int d: internal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) 8 VN-OMM0001-C Troubleshooting Seek the same trouble from the following table, and take the appropriate countermeasure.

flow Q: Air flow rate [L/mi (ANR)] P: Valve-inlet pressure [MPa] S : Effective area [mm2] t : Temperature [C] 293 273 + t Q = 120 x S (P + 0.1) 888 Series VEF/VEP Electro-Pneumatic Proportional Valve Pressure Type: VEP Diagram of Working Principle Flow Characteristics Current-Pressure Characteristics The horizontal axis of the characteristics represents the output amperage of the power