CHKDB CHKGB Double acting, Single rod 40 10 16 CX 50 5, 10, 15, 20, 25, 30 35, 40, 45, 50, 75 100 63 CY 80 100 MQQ M CHKDB CHKGB RHC MK(2) RS Q G RS H A For details, refer to the catalog CAT. E111.
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Water and Air Safety
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17
KPGU12-00 KPQU12-00 24 20.9 32 58 46 20.9 18.1 55.2 31.9 Q Note 1) D indicates the maximum diameter.
RS Q G Valve A If the converter is positioned lower than the cylinder: RS H A Drain port (Piping port) After filling with oil as described in step 4 above, close the oil filler plug. Then, introduce air pressure of approximately 0.05 MPa into the converters air port to push the oil into the cylinder.
2 x RA 2 x 2 x OA CQS Both ends tapped (CQMA) CQ2 RQ (mm) CQM Without auto switch With auto switch Bore size (mm) Stroke range (mm) P P EA EB EC MU A B F Q A B F Q TN TF TN TF 5 5.5 11.5 M5 x 0.8 40 23 32 10 to 50 50 33 7.5 10.5 45 43 34.4 Rc 1/8 NPT 1/8 G 1/8 7.5 10.5 G 1/8 Rc 1/8 NPT 1/8 75, 100 50 33 5 to 50 46.5 29.5 40 Rc 1/8 NPT 1/8 G 1/8 8 11 G 1/8 56.5 39.5 8 11 52 50 41.4 Rc
MHS2-32D MHS2-40D Q 11 12 RA 38 44 SA 4.5 5.5 FX 23 26.5 G 30.5 32 AA 44 47 NA 14 16 J 20 21 AB 41 44 L 2H9 3H9 B 56 62 DO 64 70 DC 56 62 EO 24 28 EC 16 20 CA 8 9 CB 16 17 FY 20.5 23.5 FZ 5 6 +0.025 0 +0.025 0 Model MHS2-32D MHS2-40D UA M5 x 0.8 M6 x 1 UB 10 12 VA VB 3 4 WA XA XB 3 4 SB 8 9.5 +0.025 0 +0.030 0 +0.025 0 +0.030 0 +0.062 0 +0.062 0 34H9 3H9 4H9 3H9 4H9 42H9 6 Series MHS 2
with a push button guard: KEB Release time S Release time of pressure in the cylinder Body (Red) Residual pressure release push button (Red) VCHC D With One-touch fitting without a push button guard Release button (Blue) Release button (Blue) ASR ASQ D L1 Q B A D 8 4.2 Applicable tubing W (mm) M M L2 L2 Applicable tubing Weight (g) Model Applicable tubing O.D. 6 8 10 12 D L1 L2 Q W M KEB06
D 1 5 CE-compliant Nil None Q CE-compliant Clean series Manifold type 2 Body ported 5 Base mounted Valve stations 02 2 stations Port size Nil Body ported M5 thread M5 Base mounted M5 thread C4 Base mounted 4 One-touch fitting 20 20 stations (Maximum) How to Order Valve [Option] 10 V Q D 1 1 5 1 5 L M5 Clean series Body type 3 Body ported 5 Base mounted Valve option Nil Standard
Designation Content 1 L+ +24 V for logic/input 2 P24 +24 V for output 3 L0 V for logic/input 4 C/Q IO-Link communication data 5 N24 0 V for output Fig 2-1. Pin allocation of M12 5 pins plug A-coded connector The power supply for logic/input and the power supply for output are isolated. 2.2.
Preset mode RS Q G 2. Setting of preset mode RS H A (1) Selection of preset No. PRESET RZQ Select a preset number from 1 to 31 with the UP/DOWN keys. Shift to the next item with the SEL. key. NO.
Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, SPL, VALVE, SS5Q2 MANIFOLD SQ2000, 2N, SS5Q2 NO SIZE RATING, 4.40924 lb
flow rate (l/min) Q: flow rate (l/min) Q: flow rate (l/min) Q: flow rate (l/min) d: int d: int d: int d: internal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) ernal diameter of pipe (mm) 8 VN-OMM0001-C Troubleshooting Seek the same trouble from the following table, and take the appropriate countermeasure.
flow Q: Air flow rate [L/mi (ANR)] P: Valve-inlet pressure [MPa] S : Effective area [mm2] t : Temperature [C] 293 273 + t Q = 120 x S (P + 0.1) 888 Series VEF/VEP Electro-Pneumatic Proportional Valve Pressure Type: VEP Diagram of Working Principle Flow Characteristics Current-Pressure Characteristics The horizontal axis of the characteristics represents the output amperage of the power
(mm) Model M Weight (g) L Q 3-applicable tubing D Note) KRT08-00 KRT06-00 6 10 15 25 29 KRT10-00 KRT12-00 10.6 25.6 40 57.4 6.4 17.7 28.4 45.4 12.8 20 17 15.2 23 18.5 18.5 26.5 21 20.9 28.5 22 5.3 6 6.8 7.5 8 10 12 Note) D: Max. diameter Male Branch Tee: KRT H (width across flats) Effective area (mm 2) FR soft nylon FR double layer Applicable tubing O.D.
Nominal Size: 16, Speed Specifications: Low 10 to 1000, Load Specifications: Standard Load, Nominal Size: 16 4 (5), 25 8 (10), Stroke: 600 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Top, Output Type: PNP, Stoppable Positioning Points: 3-point Stoppable Type, Cable Length: 3m, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number
Nominal Size: 16, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16 4 (5), 25 8 (10), Stroke: 300 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Top, Output Type: PNP, Stoppable Positioning Points: 3-point Stoppable Type, Cable Length: 3m, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Standard Load, Nominal Size: 16 4 (5), 25 8 (10), Stroke: 200 mm, Stroke Adjusting: None, Motor Placement: On the Bottom, Output Type: PNP, Stoppable Positioning Points: 5-point Stoppable Type, Cable Length: 3m, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch)