For applications requiring micro-mist separation up to 0.1 m with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set
Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and can be combined with other similar sized products.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MICRO MIST SEP REGULATOR, AIRLINE EQUIPMENT, AWD MASS PRO, DC, AWD MASS PRO 1/4 MODULAR NPT, 1.00255 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DC, AW MASS PRO 1/4 MODULAR (NPT), 1.27868 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DC, AW MASS PRO 1/4 MODULAR (NPT), .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DC, AW MASS PRO 1/4 MODULAR (NPT), 1.27868 lb
Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and can be combined with other similar sized products.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, DC, AW MASS PRO 1/4 MODULAR (NPT), .95287 lb
Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and can be combined with other similar sized products.
Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and can be combined with other similar sized products.
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C4 [ø4 (5/32") One-touch Fitting], Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 25 [0.5 to 25 (12.5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Body Size: 2000, Port Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Electrical Entry: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Flow Direction, Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)