A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 Adapter with throttle ZS-31-X Model No.
Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32
An example of when the SI unit station number is set to 01 is shown below.
M3 M5 01 N01 R04 R06 IM5 IM5H M5 female M5 female Port size M3x0.5 M5x0.8 R1/8 NPT1/8 M5x0.8 4 6 thread, thread, through M5x0.8 reducer reducer through type (with type mounting hole) Case Resin case: PBT Fitting: C3604BD PBT Resin case: PBT Resin case: PBT Fitting: SUS303 Fitting: A6063S-T5 Material Pressure sensing section Pressure sensor: Silicon, O-ring: NBR Oil resistance vinyl cabtyre
Front protective cover ZS-27-01 -7No.SFOD-OMO0004-B Summary of Product parts Names of individual parts Output (OUT1) display (Green): Lit when OUT1 is ON. Output (OUT2) display (Red): Lit when OUT2 is ON. LCD display: Displays the current status of charged potential, set mode condition and error code.
How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.
Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).
Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -7- How to order IR 0 0 01 BG A 0 1
Rated pressure range A B ZSE3 0 to -101 kPa 0 -101 kPa ISE3L 0 to 98 kPa 0 98 kPa ISE3 0 to 0.98 MPa 0 0.98 MPa -25No.PS-OMO0002-A Dimensions Grommet type Z/ISE3-01/T1-26No.PS-OMO0002-A Connector type Z/ISE3-01/T1-C -27No.PS-OMO0002-A Single-installation type Grommet type ZSE3-0X-28No.PS-OMO0002-A ZSE3-0X--D -29No.PS-OMO0002-A Connector type ZSE3-0X-C -30No.PS-OMO0002-A ZSE3-0X-C-D -31No.PS-OMO0002
Address setting range is 01 to 99. Setting at the time of shipment is 01. 1 9 0 9 0 1 2 2 8 8 7 3 7 3 6 4 6 4 5 5 8 - Setting the terminator Set PROFIBUS communication line terminator. With Terminator (at shipping) Without terminator Without terminator When the product is connected to the terminal of PROFIBUS communication line, be sure to set it to with terminator.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24-
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the starting point return is changed from CCW to CW. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) 32 - 5. Wiring of cables / Common precautions Warning 1.
Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 to 1. Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -28-
Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-40No.EX-OMP0013-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [
BA -02 BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Useable range 10 10 Load Work piece Useable range 5 5 Fn 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 7 8 9 1 01 11 21 31 41 5 Lo Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B40 CY3B20 Selection example 500 200 Given a load drive resisting force of Fn = 100 (N) and a distance from the cylinder shaft center to the load application point of Lo =
1 3 Port Air Operated Valve Series VPA300/500/700 How to Order SA A 01 2 4 3 VPA VA Option VP Air operated valve None With bracket (Only VPA342, VPA542 and VPA742) Nil F SA Body size VPA542 Passage 3 5 7 1/4 standard 3/8 standard 1/2 standard VA Normally closed Normally open A B Thread type VM NC/NO common 4 Actuation Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (4) 1 Plug-in Unit (3) Direct exhaust with silencer box: Exhaust from both D and U sides Direct exhaust with silencer box: D side exhaust Direct exhaust with silencer box: U side exhaust IP65 enclosure (except F and T1 kits) (2) 1 station Station (2) 01
5 Port Solenoid Valve Body Ported/Single Unit Series SY3000/5000/7000/9000 How to Order 5 L SY 5 1 20 01 Series Bracket 3 SY3000 5 SY5000 Nil: Without bracket F1: With foot bracket A, B port size Thread piping 7 9 SY7000 SY9000 2 position single only Symbol Port size M5 x 0.8 SY3000 Applicable series M5 1 8 01 SY5000 1 4 SY7000 02 02 03 Type of actuation Coil specifications 1 4 Standard Nil
Kit (Connector Kit) How to Order Manifold C W VV5Q 5 5 08 03 Series Option 5 VQ5000 Option None Exhaust cleaner for Rc 1: D side exhaust Exhaust cleaner for Rc 1 1/2: D side exhaust Exhaust cleaner for Rc 1: U side exhaust Exhaust cleaner for Rc 1 1/2: U side exhaust Symbol Nil CD1 CD2 CU1 CU2 SB SD SU W Manifold Note) 5 Plug lead unit Note) Kit type Note) C Stations kit (Connector) Note) 01