SMC Corporation of America
Elite Part Number Search
Search Results "PSE561-N02-28"

5.5 5.5 7 7.5 6.5 5.5 D-F5/ J59 D-F5W/ J59W D-F5BA/ F5NT D-F59F 3.5 4 4 4.5 4.5 4.5 D-G39/ K39 9 9 9 10 10 11 D-P3DWA 3 4.5 4.5 5 5 5.5 D-P4DW 4 4 4 4.5 4 4.5 D-A9/ A9V 7 7.5 8.5 9.5 9.5 10.5 D-Z7/ Z80 7.5 8.5 7.5 9.5 9.5 10.5 D-A5/ A6 9 9 10 11 11 11 D-A59W 13 13 13 14 14 15 D-A3/ A44 9 9 10 11 11 11 * Values which include hysteresis are for guideline purposes only, they are not a 27 - 28

The figure shows the mounting example for the D-M9(V)/ M9W(V)/ M9A(V)/ A9(V) They are not a guarantee (assuming approximately 30% dispersion) and may change substantially depending on the ambient environment. 25 - Auto switch proper mounting position (detection at stroke end) and its mounting height 26 - 27 - 28 - 29 - 30 - 3-4. Wiring method and examples of auto switches 31 - 4.

Specifications 19 Weight 19 Effective torque 20 Internal construction and parts 20 MSQ1 to 7 21 Basic circuit 21 Circuit structure 21 Recommended models 22 Mounting 22 Load restrictions 22 Unit used as flange mount 23 Direction and Angle of Rotation 24 Rotating range examples 25 Piping 25 Air supply 26 Setting of rotation time 26 Moment of inertia 27 Calculation formulae for moment of inertia 28

Weight 20 Effective torque 20 Rotation range 21 Internal construction and parts 21 Size 10, 15 22 Size 20, 30, 40 23 Basic circuit 23 Circuit structure 24 Mounting 24 Load restrictions 24 Operation of axis fitting referring 25 Unit used as flange mount 25 Rotating range examples 25 Air supply 26 Setting of rotation time 26 Moment of inertia 27 Calculation formulae for moment of inertia 28

1060 mm 0.01 c.p.m. 120 60 21 37 63 111 177 280 502 1 N 23 42 71 123 195 306 537 mm 4 4 6 8 8 12 16 g 58 96 134 265 345 515 952 1) 1625 L=20mm 3263 L=30mm 0.5MPa MHS3 16D MHS320D MHS325D MHS332D MHS340D MHS350D MHS363D MHS380D MHS3100D MHS3125D MHS3mm 16 20 25 32 40 50 63 80 100 125 MPa 0.20.6 0.10.6 -1060 mm 0.01 c.p.m. 120 60 30 14 25 42 74 118 187 335 500 750 1270 (1) N 16 28

Auto switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9P-5 Wiring 3-wire Output PNP type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage 100 A

Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less

Auto Switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9N-5 D-M9P-5 Electrical entry direction In-line Wiring type 3-wire Output type NPN PNP IC circuit, Relay, PLC IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or

Accessories Table spacerParallel motor only Model Part name QTY EQFS25(L/R) Table spacer 1 EQFS32(L/R) EQFS40(L/R) Optional parts (sold separately) Power supply cable Parallel I/O cable Communication cable USB cable Setup software Refer to 9 Optional parts (sold separately) for details of optional parts. 28 - Installation and Initial Setting .

LEKFS series slider type / Common precautions . 24 5.1 Design / selection . 24 5.2 Handling . 24 5.3 Mounting . 25 5.4 Precaution on maintenance . 26 3.5 How to detach and attach the dust seal band . 27 5.7 Replacement of belt . 28 6.Troubleshooting . 29 6.1 Alarms . 29 -1- LEKFS Series / Electric Actuator Safety Instructions These safety instructions are intended to prevent hazardous situations

Accessories . 28 Installation and Initial Setting .29 . Flow from installation to initial setting. 29 . Check the contents of the package . 30 . Preparation of necessary supplies . 31 . Installation of electric actuators . 32 . Wiring and Connection . 33 .. Connection to input power supply . 33 .. Connection to PC . 38 .. Connection to PLC . 38 . Power ON alarm (error) . 40 .

Vertical 2] 5000 deceleration[mm/s Position repeatability [mm] 0.01 note4) 0.1 or less Lost motion [mm] Screw Lead [mm] 10 5 2.5 12 6 16 8 Impact / Vibration note5) 50/20 2] resistance [m/s Actuation type Ball screw (In-Line) Ball screw + Belt (Parallel) Guide type Linear guide(circulating type) Operating temperature [] 540 Operating humidity [%RH] 90 or less(no condensation) Motor size 28

Absolute Speed 2 SpeedSET 2 Position 3 Key pad entry 5.3231 JOG input 5.3232 Direct input 5.3233 2 AccelerationSET Deceleration 28 - 2 Pushing force 1 INP ON 2 Trigger LV(Trigger level) SET 20mm/s 3 2 In positionSET MENUESC 126.1 (2-2-b) TB Ver2.** TB Ver.5.11 Step data AX IS. Menu 1 Step data Parameter Test SET 2 Move mode AX IS. Step 1 No.

Initial Setting . 27 4.1 Switch (STATION NO., B RATE) . 27 4.2 Parameter Setting . 28 4.3 PLC Setting . 29 5. External Connections . 30 5.1 PWR: Power supply connector . 30 5.2 MOT: Motor connector, ENC: Encoder connector . 30 5.3 SI: Serial I/O Connector . 30 (1) Connecting the teaching box . 30 (2) Connection with a PC . 31 5.4 CC-Link communication connector . 31 6.

(JXC917-) . 14 (2)DIN (JXC918-) . 15 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 (IP ) . 18 4.2 . 19 TMEtherNet/IP TM . 20 4.3 RSLogix5000 4.4 EtherNet/IP . 22 5 . 23 5.1 PWR . 23 5.2 MOT:ENC: . 23 5.3 SII/O . 23 (1) . 23 (2) . 24 5.4 P1P2: EtherNet/IP . 24 6 . 25 6.1 . 25 6.2 . 25 6.3 . 26 (1)(C24V,M24V,0V) . 26 (2)(EMG) . 26 (3)(LK RLS) . 26 6.4 . 27 (1)() . 27 (2)() . 28

Please turn off the EMG terminal when energizing to the BK RLS terminal at motor drive power is OFF. 28 - 6. CN5: Parallel l/O Connector 6.1 Parallel I/O specifications Input specifications Output specification (NPN,PNP common,pulse signal input (NPN and PNP common) terminal is excluded.) No. Item Specification No.

Recommended tightening torque for the port Unit: N m Thread size 1/8 1/4 3/8 1/2 3/4 1 Torque 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 4. Before using an SMC fitting and S coupler, please refer to "Tightening the threaded portion of the connection thread" of the Fittings & Tubing Precautions. 5.

Definition and terminology 9 Assembly 10 Mounting and Installation 12 Installation 12 Wiring 14 SI Unit Model Indication and How to Order 15 Summary of Product parts 15 Mounting and Installation 16 Wiring 16 Setting and Adjustment 17 LED Display 21 Specification 25 Specifications 25 Dimensions 26 End Plate Model Indication and How to Order 27 Summary of Product parts 27 Mounting and Installation 28

Installation 12 Installation 12 Wiring 14 Analog input unit Model Indication and How to Order 15 Names and Functions of Product 15 Mounting and Installation 16 Wiring 16 LED Display 18 Specification 19 Specifications 19 Dimensions 24 Analog output unit Model Indication and How to Order 25 Names and Functions of Product 25 Mounting and Installation 26 Wiring 26 LED Display 27 Specification 28

Status Condition 0 No supply voltage SP Status of solenoid power supply 1 Supply voltage OK 0 Short circuit DI Status of sensor power supply 1 Normal Output area mapping Output data MSB LSB MSB LSB Offset (word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -28No.EX-OMK0004-B Output No. assignment Combinations of output data and valve