EX180-SMJ3/5 EX180-SMJ3A/5A (EX180-CMJ1) (EX180-CMJ2) Power supply connector (2 pcs.) (EX180-CP1) Accessories No. Element Description 1 Fieldbus interface connector (BUS) The connector for CC-Link ( ) that is used to connect to the CC-Link bus line. The connector for the power supply ( ) that is used to supply the power for 2 Socket for the power supply (PWR(V)) the solenoid valves.
ZS-10-5A-50 . 1 pc.
Linefilter ; 250VAC, 3-5A rating Z lap ; 39-47VDC 0 Connect lead wire after twisting and soldering. O Connect to 24VDC, outBJt, sitnal, sensor and detect terminals. Shielded wires are recommended for connections to siqnal and sensor terminals. NOTE: The 24VDC and the G5\,DC signal voltage must have separate isolated grounds.
Polarity SOL.A 1A ( ) ( + ) SOL.B 1B ( ) ( + ) 1 station 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A ( ) ( + ) SOL.B 2B ( ) ( + ) 2 stations SOL.A 3A ( ) ( + ) SOL.B 3B ( ) ( + ) 3 stations SOL.A 4A ( ) ( + ) SOL.B 4B ( ) ( + ) 4 stations SOL.A 5A ( ) ( + ) 10A COM SOL.B 5B ( ) ( + ) 5 stations
B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.
However, the maximum number of stations is 16. 1B 2A 2B 3A 3B 4A VFR 4B 5A 5B 6A 6B 7A 7B VQ7 1.
SOL.A 1A 1B Station 1 SOL.B 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A 2B Station 2 SOL.B 1. How to Order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet.
VXK21 VXK22 VXK23 VXK021N-5A Nil NBR C37 B Non-leak (106 Pam3/sec), Oil-free, Medium vacuum (0.1 Pa.abs) V FKM When using with vacuum, consider the max. differential pressure. (0.1 MPa or more is recommended.) Fluid: Air When you operate the VX series (AC spec.) by air, the built-in full-wave rectifier type is chosen.
SOL.A 8A () (+) SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 8B () (+) 8 stations SOL.B 8B SOL.A 9A () (+) SOL.A 9A SOL.B 9B () (+) 9 stations SOL.B 9B SOL.A 10A () (+) SOL.A 10A SOL.B 10B () (+) 10 stations SOL.B 10B (+) () COM COM Note) There is no polarity.
EX180-SDN3/4/5/6 EX180-SDN3A/4A/5A/6A (EX180-CDN1) (EX180-CDN2) Power supply connector (1 pc.) (EX180-CP1) Accessories No. Element Description The connector for DeviceNetTM ( ) that is used to connect to the DeviceNetTM 1 Fieldbus interface connector (BUS) bus line.
Gasket DXT144-13-3A Round head combination screw DXT031-44-1 (M4 x 39.5, With spring washer) VFA1000 DXT144-12-2 DXT031-38-5A VFA3000 DXT155-25-7 VF5000-70-1A Hexagon socket head cap screw AXT620-32-1 (M4 x 48, With spring washer) VFA5000 DXT156-9-6 Individual EXH spacer assembly Caution Tightening Torque for Mounting Screw M4: 1.4Nm Warning When mounting a valve or spacer on the manifold
A Slotted locking type B (tool required) B Light/surge voltage suppressor D DZ DIN terminal DIN terminal with light/surge voltage suppressor Semi-standard CE-compliant Electrical entry/ With light/surge voltage suppressor CE-compliant Accessory Function plate for VO307 (D seal, with thread): DXT152-14-5A GS Grommet with surge voltage suppressor G Grommet E Grommet terminal EZ Grommet terminal
i 2.80 2.40 Q.2A 0 . 1 6 1 7 1 ) (4) c0P-5A 80 3.01 2 6 2 4.20 0 . 1 6 (76.5) (66.5) i5) {4) CDF 64 a0 i00 3,27 2.97 0.20 0.16 {83) (5) t4) 100 0 9 8 3.46 3.07 0.20 0 1 6 (88) (78) (5) REPAIR Cylinder Repair Kits (All rubber seals) Gauges ActuatorAssembly #1P200-02 Actuator Bepair Kit #1P200-RP Consists of: Back Pressure Diaphragm Supply Diaphragm Input Diaphragm Packing 4 Spool & Sleeve
(DC24V) DC24V10 (1) 3A 5A 2 (3) 11 () 13 () A/B (800 /) RS485 Modbus EEPROM LED LED/1 I/O 5m 20m 0~40 90%RH ) -10~60 90%RH ) ()FG 50MDC500V 150g() 170g(DIN ) 1 2 3UL UL1310 Class2 11 - 3.2. ( SV1.00 ARX8300073 ()"SV1.00" ON/ ()/ 1 PWR LED() (LED()) () 2 ALM LED() ON/ 3 CN5 I/O (26 ) I/O PLC (11 COM 13 COM ) 4 CN4 I/O (8 ) 5 CN3 (16 ) 6 CN2 (6 ) 7 CN1 5 (DC24V)
ZS-20-A 16 NPN Open Collector 2 output w/o analog output, 3 revolution adjustment ISl IWith lead wire ZS-20-5A 17 NPN Open Collector 2 output w/o analog output, 200 revolution adjustment Note) When ordering switch with 5m long lead wire, indicate both part numbers. Ex.) ZSE1-01-15CN1 pc. ZS-20-5A-501 pc.
Stainless steel Types 10, 20 VVDW 2 0 5A Series 1 2 10 20 Type 30 VVCW20-5A 12 Compact Direct Operated 3 Port Solenoid Valve for Water and Air Series VDW100/200 How to Order Valves (Single Type) VD W 2 50 1 G 2 01 For water, air and vacuum Series Option 2 3 200 300 None Foot type bracket Nil F Note) Foot brackets are packed with valves. Materials and insulation type C.O.
G Grommet A Grommet with surge voltage suppressor GS Slotted locking type B (tool required) B D DIN terminal DIN terminal with light/ surge voltage suppressor Semi-standard DZ Electrical entry/ With light/surge voltage suppressor Accessory Function plate for VO307 (D seal, with screw): DXT152-14-5A CE-compliant GS Grommet with surge voltage suppressor G Grommet E Grommet terminal EZ Grommet
Individual, Common Not required (Use turbine oil #1(lSO VG32) if lubrication is Free 30Gy'5G (8.5 -2000H2) Dust proot Solenoid S ifications Grommet (G) (H), Plug connector (L) (M), DIN connector (D) 1 1 OV 5 a/6aqz, 220V. a I oqz 24V 5a,1a Hz 12V,24V 15+10% of rated voltage utass E ot equrvatenl (z5u r l 81'F or less 1.8W,,,2.1W (W/LED) 4.zVA/6OHz 4.5vA/soHz 3VA/60H2 3.5VA/50H2 DC : Diode
ZS-20-5A-50 1pc. 5 Ejector Valve Unit Series ZYY/ZYX How to Set the Pressure How to Use the Connector Internal Circuits and Wiring Examples 1. Installation and removal of connector ZSE1-14, -15 The ON pressure is set with the pressure setting trimmer. High vacuum settings are obtained by turning it clockwise.