Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 4 (2000mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 3 (1000mm), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread:
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Manual Override), A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: Y [DIN Terminal w/Connector (DIN 43650)], Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 3 (3 Position Closed Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 3 (3 Position Closed Center), Sealant: 0 (Metal Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 3 (3 Position Closed Center), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 3 (110VAC 50/60HZ), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)