Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.
Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.
(inch) 4 6 8 10 12 Accessory Model TM-04 TM-06 TM-08 2 x 6 T TM-04 TM-06 TM-08 TM-10 TM-12 2.6 x 8 4 TM-10 VMG 3 x 8 TM-12 Dimensions: Multi-tube Holder (Pitch) N-holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.
Dimensions(mm) 1in = 25.4mm Model Metric size D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Inch size TMH-05 21 8.3 8.5 15.4 7.7 9.3 6.4 6.3 3.3 11.7 TMH-06 13.1 10 TMH-07 26.5 10.6 11 20 10 11 7.2 7.1 4.3 13.5 TMH-08 TMH-09 15.5 TMH-10 18.5 34 14.6 14.2 28 14 14 9.6 9.5 4.3 TMH-11 18.8 SMC Pneumatics, Inc. 6 SMC Pneumatics, Inc. 7 World Wide Support...
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Recommended air flow Tubing size Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Unrestricted 360 piping tube mounting. The connector for the IN side is a universal joint type that enables a tube to be connected in any direction within 360.
(mm) Model Model Accessory TM-04 TM-06 TM-08 2 x 6 TM-04 TM-06 TM-08 TM-10 TM-12 4 6 8 10 12 2.6 x 8 4 TM-10 3 x 8 TM-12 Dimensions: Multi-tube Holder N x D (Pitch) N x holding part Cutting groove for separation N (No. of holding parts) Applicable tubing O.D.
(4D-P34) KA00733 (4D-P60) 04 to 08 AL-180H-V AL-183H-V AL-162H-V FKM or EPDM Element opening 10 to 16 AL-181H-V AL-184H-V AL-163H-V Band Element w 20 to 24 AL-182H-V AL-185H-V AL-164H-V Case Note 1) The material of seals (AL-162H-V to AL-164H-V and AL-180H-V to AL182H-V) is EPDM.
Vacuum Unit Series ZK2 RoHS How to Order Single Unit Vacuum Pump System 08 P K 5 A L ZK2 00 ZK2 08 A K 5 A L 12 Ejector System (with Valve) ZK2 08 A N 0 N N 12 Ejector System (without Valve) Remains blank when option is not selected. q e r t y u i w e Combination of Supply Valve and Release Valve Note 3) q System/Body Type Supply valve Release valve Supply valve Release valve System Body
L-04 L-06 N-04 N-06 LL-04 LL-06 S-04 S-06 4 6 L-08 8 L-10 10 L-12 12 4 6 N-08 8 N-10 10 N-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 4 6 S-08 8 S-10 10 S-12 12 0.7 1.1 1.4 1.7 2.0 Precautions Be sure to read before handling. Refer to Air Fittings & Tubing Precautions for other details. Installation Caution Cut the tube to the required length.
Dimensions Model Metric size D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Inch size TMH-05 21 8.3 8.5 15.4 7.7 9.3 6.4 6.3 3.3 11.7 TMH-06 13.1 TMH-07 26.5 10.6 11 20 10 11 7.2 7.1 4.3 13.5 10 TMH-08 TMH-09 15.5 TMH-10 18.5 34 14.6 14.2 28 14 14 9.6 9.5 4.3 TMH-11 18.8 5
Positioning hole Positioning hole Caution e One-touch fitting Tightening torque: 0.12 Nm q Unit Assembly Part No. r Bracket Assembly Part No. 00 VV061 08 5 H Description Part no.
(Refer to page 40, 41) Standby OFF delay 0 to 9s 0s Common Sensor Sets enabling/disabling of automatic isolation. (Refer to page 40, 41) Auto isolation Enable/Disable Disable Common Isolation delay Sets isolation delay. (Refer to page 40, 41) 0 to 9s 3600s Common Sets whether it is necessary to input the security code or not.
(P.41) (CN1: EMG OFF 3.(P.12) ) INP ON (INP 9.1 (P.32) PLC ) 5 3.(P.12) PLC (PLC) 2 11.4 (P.49) () 10.(P.41) 3.(P.12) -81- 5(P.23) 9.1 (P.32) 3.(P.12) PLC (PLC) 2 11.4 (P.49) () () 3.2 (P.13) USB 10.(P.41) 5 10.(P.41) 10.(P.41) 3.(P.12) ( EMG ) 3.
Mass (g) D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Do not fix the auto switch with the existing screw installed on the auto switch body.
6 5.4-41 -XC10 Dual stroke cylinder/Double rod !7 Made to order common specifications 5.4-46 -XC11 Dual stroke cylinder/Single rod !8 5.4-52 -XC12 Tandem cylinder !
Operating temperature range 41 to 122F (5 to 50C) Operating humidity range [%RH] 90 or less (No condensation) Weight [g] 350 (Except cable) Note) CE-compliance The EMC compliance of the teaching box was tested with the LECP6 series step motor controller (servo/24 VDC) and an applicable actuator.
Detailed information of units 41 3.4.1. Information tab 41 3.4.2. Details of I/O monitor tab 50 4. Setting Function 57 4.1. Edit TAG 57 4.2. Software Control 57 4.3. Forced output 60 4.3.1. Forced output conditions 60 4.3.2. Forced output procedure 60 4.3.3. Forced output release procedure 63 4.4. Export Settings 64 4.5. Import Settings 66 4.6. Reading of the initial value 67 4.7.
[F20] 45 [F22] 46 OFF [F30] 47 OFF[] [F32] 48 OFF[] [F33] 50 FR0 [F34] 51 OFF [F80] 52 [] [F81] 53 OFF [F82] 54 [*] [F90] 55 OFF [F98] 56 OFF [F99] 57 OFF 30 [F10](41 ) OUT2 (20L/min ) OFF OFF OFF OFF 27 No.LFE*-OMY0008 [F 1] OUT1 OUT1 1. 1. 1. 1.
100 157.5 50 36 59 15 8 35 16 85 47 90 43 14 31 19 36 Lube Non-lube Air-hydro M30 X 1.5 to 1400 1401 to 1600 100 161 128 M14 X 1.5 188 112 180.5 50 36 59 15 9 35 16 14 19 47 90 43 31 36 1/2 3/4 M36 X 1.5 to 1400 1401 to 1600 18.5 106 197 182 144 M16 X 1.5 206 118 14 19 53 90 43 36 45 56 40 59 17 9 39 M40 X 1.5 3/4 to 1800 1801 to 2000 18.5 125 227 204 162 115 M18 X 1.5 231 132 60 48 17 41
Changing PD04 from 00212100 to 0021210D 0 D 41 - (2) Symbol allocation using the setup software: Changing pins CN1-16 to Gain changing selection (CDP). Change PD04 from 00212100 to 0021210D in the I/O tab. Select Single Axis Write. Cycle the power the parametersto be enabled.