Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes.  Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge.  The modular design of the AR series connects with other SMC air preparation equipment., REGULATOR, TAMPER

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is

For applications requiring micro-mist separation up to 0.1µm with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: K (w/Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certificate: K (w/Certificate)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)