Do not expose the product to direct sunlight for an extended period of time. 1/4 12 to 14 3/8 22 to 24 3. Do not use in a place subject to heavy vibration and/or shock. 1/2 28 to 30 4. Do not mount the product in locations where it is exposed to radiant heat. 2.
(Connection port center) (Connection port center) F (Bracket mounting dimensions) Bracket (Option) B C A INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model Port size Rc 4 1 63 63 80 85 90 100 141 164.5 170 180 230 251 15 15 15 20 22 22 8 3 , , 8 3 4 1 2 1 Bracket dimensions E C D B A Model Port size 4 3 F 345 419.2 G 32.5 0 H 95 120 J 14 14 K 57 49.6 1 1 , 87.5 125 4
L dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No.
Connection Female Thread: Rc, NPT, NPTF Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 Connection thread size Proper tightening torque [Nm] NPT, R1/8 3 to 5 NPT, R1/4 8 to 12 NPT, R3/8 15 to 20 NPT, R1/2 20 to 25 Connection Female Thread: G Chamfered area for female
91 AS421F-G04-10W2D G1/2 24 19.5 28.6 25 12.4 33.6 47.9 26.8 65.3 1.2 56.7 21 150 AS421F-G04-12W2D 20.9 34.6 48.9 22 156 2 These safety instructions are intended to prevent hazardous situations and/or equipment damage.
.: 0.5 MPa Operating oil: Additive turbine oil Class 1 (ISO VG32) Oil piping length: 1 m Flow control valve Flow control valve Throttle valve Throttle valve Stop valve CCVS10/11/12/13 CCVS20/21/22/23 CCVS02 Piping bore Piping bore Piping bore Piping bore Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) No load No load No load
-X 545 C(L)KU32 Series Auto Switch Mounting 2 Auto Switch Mounting Height Applicable cylinder: C(L)KU32-X2321 C(L)KU32-X2322 D-P3DWA 44.5 23.5 D-M9V D-M9WV 40 35 D-A7 40 22 546 Auto Switch Mounting C(L)KU32 Series Auto Switch Mounting Bracket Part No.
D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V Rotating angle Size Operating range ( ) Operating range ( ) Proper mounting position A (mm) Proper mounting position A (mm) 90 13 9 30 42 81 180 22 18 Operating range at proper mounting position /2 90 22.5 18.5 50 30 44 180 39 35 Most sensitive position Operating range of single auto switch Values which include hysteresis are for guideline purposes
63: L 0 -0.2 8 x V Effective thread depth Y H A B E G Mounting nut width across flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22
C 9 10 D 22 24 E 59 66 F 33 34 G 24 25 H 30 40 J 36 46 K 6 9 M 45.5 50.5 N 69 76 VVXA31 VVXA32 17-3-108
Panel mounting hole Roller plunger VZM550-01-06 VZM550-01-06S 12 (Polyacetal or hard steel roller) Hexagon nut thick 8, across flats 22 JIS Symbol (Pilot exhaust port) 0.5 MPa supply 1.5 mm P.T. 18 N F.O.F. 2.0 mm O.T. 2-3.2 mounting hole 3.5 mm T.T. Panel mounting hole Toggle lever VZM550-01-08 T.T.
300 (Lead wire length) 3 position 171.5 Double 164 Single 106 MAX.10 79 With light/surge voltage suppressor Pg7 103 95.4 PE P EB EA n: Stations L Stations Formula 20n + 21 20n + 30 2 61 70 3 81 90 4 101 110 5 121 130 6 141 150 7 161 170 8 181 190 9 201 210 10 221 230 11 241 250 12 261 270 13 281 290 14 301 310 15 321 330 16 341 350 17 361 370 18 381 390 19 401 410 20 421 430 21 441 450 22
Bellows protection structure Wiper Detail drawing OPEN 528 Slit Valve XGT Series RoHS How to Order XGT 22 2 46236 1 C Auto switch and the connector (Refer to the table below) High vacuum slit valve Valve size Gate O-ring material Number of axis Two axes bellows One axis bellows Applicable wafer size 200 mm 300 mm Symbol 22 31 Material FKM Kalrez 4079 Symbol 1 2 Opening window size Width Height
For polyurethane tubes, 22 colors other than the ones above are available. 1114 Series ZFC100/200 Made to Order Specifications Please contact SMC for detailed specifications, dimensions and delivery. Air Suction Filter with Metal Case 1 Max. operating pressure 0.5 MPa For the standard type, the max. operating pressure is up to 0 kPa.
NCX2N10 0.15MPa / 22 PSI NCX2N1S Min Operating Pressure 0.15MPa / 22 PSI NCX2N2S 0.1MPa / 15 PSI S E L E C T O R 5 ~ 60C / 40 ~ 140OF Ambient and Operating Fluid Temp See List Below Piston Speed (Non-Lube Type) With Shock Absorber (Option) Cushion 2~25.4mm / +0.08 ~ -1 inch Stroke Adjustment Range NCX2N10 1Kg / 2.2 lb NCX2N1S Note 1) Max Movable Load 3Kg / 6.6 lb NCX2N2S 6Kg / 13.2 lb +0.1O
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 380, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) IDF-TR500-3 15 Single phase Single turn 100 VAC (50 Hz) 110 VAC (60 Hz) IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 230 207 190 210 160 9 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) IDF-TR500-4 22 11 13 Accessory (Option) Base Integrated with a Transformer
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J K Draft air outlet A B D E Power cord outlet Air outlet Air inlet 22 C Draft air inlet F L 16 M HA AT Model IDUS3E IDUS4E Port size A B C D H K J L M E F G 297 330 315 380 260 470 540 85 130 350 325 440 Rc 1/2 ID 85 130 Rc 1/2 440 260 560 540 297 330
Since this will make it impossible to satisfy the specifications, operate with adjustment within the range of maximum values. 11-5-22 22 Rotary Table: Basic Type Vane Style Series MSUB These drawings indicate the condition when the B port is pressurized.
.: 0.5 MPa Operating oil: Additive turbine oil Class 1 (ISO VG32) Oil piping length: 1 m RE A B Flow control valve Flow control valve Throttle valve Throttle valve Stop valve REC CX CCVS20/21/22/23 CCVS02 CCVS10/11/12/13 CY Piping bore Piping bore Piping bore Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) Cylinder driving speed (mm/s) MQQ M Courtesy of Steven Engineering, Inc
Applicable bore A 1.08 B 0.38 C 5/8-18 UNF D 20JM-08 0.94 3/4", 7/8" 1 1/16" JM-10 1.12 1.30 0.42 3/4-16 UNF 1 1/4", 1 1/2" Data JM-14 1.61 1.86 0.43 1 1/4 -12 UNF 2" 6-14-21 22 Series NCM Double Acting/Single Rod/Band Mounting Auto Switch Mounting Position and Mounting Height D-H7/H7W/H7F/H7BAL D-C7/C8 HS HS 0.63 0.63 SMC SMC 1.02 A B A B 1.14 (1.42) ( ): D-H7LF D-G59/K59 D-B5/B6/B59W