about the rod end nut and accessory brackets, refer to page 7-6-20. 7-4-10 11 Series CQS Compact Cylinder: Standard Type Double Acting, Single Rod Foot Style Foot style: CQSL/CDQSL B + Stroke Special cap bolt Standard stroke range (mm) Long stroke range (mm) Without auto switch With auto switch Without/With auto switch Long stroke Standard stroke Bore size (mm) LS B 20 20 29 29 A 32 32 41
A A1 E1 L1 NZ 16 16 20 22 28 38 44 34 41 42 56 71 79 25 30 30 40 50 55 20 25 32, 40 50, 63 80 100 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10 Y-G02 Y-G03 Y-G04 Y-G05 Y-G08 Y-G10 34 41 42 56 71 79 25 30 30 40 50 55 IY-G02 16 20 IY-G03 20 22 IY-G04 36 28 IY-G05 44 38 IY-G08 56 44 IY-G10 Knuckle pin and snap ring are included. 64 Knuckle Pin (Common with double clevis pin
The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ7000 valves, Supply and exhaust ports common, Valves individually wired, Maximum 20 stations available as standard (types 21, 40, 41, 42); maximum 15 stations available as standard (type 20), 11 port sizes available, SYJ 5 port valve manifold, 4/5 PORT SOLENOID VALVE
Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.
Mode button 1s Set button 1s or Mode button 1s Set button 1s Fig. 41-1 No.IP8S-OM09 57 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-2 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-3 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant
(1) Operation check by test drive . 41 (2) Operation check with the monitor . 41 5.4.1 Operation check by test drive. 41 (1) Operation check by test drive in easy mode . 41 (2) Operation check by test drive in normal mode . 43 5.4.2 Operation check with monitor . 45 (1) Operation check with monitor in easy mode . 45 (2) Operation check with monitor in normal mode . 46 6.
Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
If screws other than those specified are used, it may cause the switch to be damaged. 3 41 41 38 5 68 68 63 Auto Switch Dimensions Unit: mm Auto switch internal circuits D-M9 Mounting screw M2.5 x 4 Slotted set screw D-M9N D-M9B, N, P Common DC (+) Brown [Red] Indicator light 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black [White] 2.7 2.8 4 22 DC (-) Blue [Black]
Refer to page 204 regarding brake wiring. 600 a = 2000 a = 1000 400 a = 3000 a 200 L3 Mey 0 5 10 20 15 Transfer load m (kg) Refer to page 145 for deflection data. 40 41 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Standard Motor/Vertical Mount Specification Series
Dimensions GC GC S + (2 x Stroke) Stroke B Stroke A ZZ + (2 x Stroke) ZZ + Stroke (A + B) S + Stroke (A + B) ZZ 262 320 320 S 200 244 244 GC 43 52 52 ZZ 231 235 262 S 180 180 200 Bore size (mm) 32 40 50 GC 36 38 41 Bore size (mm) 63 80 100 Bore size (mm) 32 40 50 63 80 100 GC 36 38 41 43 52 52 S 178 178 198 198 242 242 ZZ 272 280 314 314 386 386 NPT ports XC18 15 Dual stroke cylinder/single
D-M9BW(V), D-M9NW(V), D-M9PW(V) Stroke (mm) 20 41 29 41 29 47 35 Stroke (mm) Model Model Normally closed (NC = b contact) solid state auto switches (DF9G/F9H types) and a solid state auto switch (D-F8) are also available.
D-M9N-746 D-M9P-746 D-M9B-746 0.5 8 8 7 Lead wire length m Auto Switch Internal Circuit 3 41 41 38 5 68 68 63 MHZ D-M9N-746 MHF DC(+) Brown Auto Switch Dimensions Main circuit of switch Main circuit of switch Main circuit of switch MHL OUT Black D-M9N-746/D-M9P-746/D-M9B-746 MHR Mounting screwM2.5 x 4l Slotted set screw Indicator light DC(-) Blue MHK D-M9P-746 MHS 2.6 746 DC(+) Brown MHC
41 40 5H9 0 +0.030 M6 x 1 37 6.8 10 17 10 28 21h9 -0.052 0 55 6H9 0 +0.030 19.5-0.1 0 50 47 M8 x 1.25 51 8.6 12 34 22 12.5 1428 Escapements Series MIW/MIS Finger options Tapped on upper and lower faces Tapped on all faces Attachment mounting thread 4 x FD through Attachment mounting thread 2 x FD through FF FE FF FE Attachment mounting thread FD thread depth FG FC FC RSQ FA FF FE FA RSG
C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM B 6 6 6 6 6 C 22 27 32 41 41 Part no. Part no. Part no.
The switch may be damaged if a screw other than the one supplied, is used. 0.28( 8) 0.28( 8) 0.25( 7) Lead wire length in(m) 118(3 ) 1.45(41) 1.45(41) 1.34(38) 197(5 ) 2.40(68) 2.40(68) 2.22(63) Auto Switch Internal Circuit Unit: in Dimensions D-M9N, M9NV ( ): mm D-M9 Mounting screw M2.5 x 4l Slotted set screw Indicator light DC (+) Brown 0.10(2.6) Switch main circuit OUT Black 0.11 (2.7)
Weight [g] D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.The auto switch may be damaged if a screw other than the one supplied is used. 5 68 68 63 How to Order D-M9 N Auto Switch Internal Circuit D-M9N(V) Series Lead wire length Nil M L Z 0.5
Caution 0.5 8 8 7 Operating Precautions 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the switch with the existing screw installed on the switch body.
Return to origin . 41 8.1 Return to origin . 41 8.2 Positioning operation . 41 8.3 Pushing operation. 42 (1) Pushing operation is successfully performed. . 42 (2) Pushing operation is failed (pushing the air) . 42 (3) Movement of the work piece after the completion of the pushing process .. 42 8.4 Controller input signal response time . 43 8.5 Methods of interrupting operation . 43 9.
55 + Stroke 18 91.5 Special cap bolt 46 CLJ2 5 4 x 11 95 3.2 9 16.2 9 16.2 CLM2 113 70 + Stroke 122.2 + Stroke CLG1 CL1 MLGC Rod end nut 43.5 CNG Rod flange style: RLQF63 MNB CNA 60 80 CNS 9 4 x 9 92 41 55 + Stroke 18 108 CLS 114 + Stroke CLQ RLQ 43.5 Rod end nut MLU Head flange style: RLQG63 MLGP ML1C 80 60 41 55 + Stroke 9 8 92 4 x 9 113 + Stroke 108 Rod end nut 43.5 Double clevis style
A A1 E1 L1 MM U1 NZ L 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.4 +0.2 +0.058 0 20 I-G02 Y-G02 20 8 8 IY-G02 34 8.5 16 25 M8 x 1.25 10.3 11.5 8.5 16 25 M8 x 1.25 10.3 11.5 16 21 8 8 34 +0.058 0 +0.4 +0.2 25 I-G03 Y-G03 25 10 10 IY-G03 41 10.5 20 30 M10 x 1.25 12.8 14 10.5 20 30 M10 x 1.25 12.8 14 20 25.6 10 10 41 +0.5 +0.3 0.3 0.5 0.3 0.5 0.3 0.5 +0.058 0 +0.070 0 +0.070 0 +0.058 0 32, 40 I-G04