It cannot be mounted at a later time or used as a separate unit.
A O OUT 2 I N 1 SMC A J A IN OUT H G M Parts list Material Note Description No.
Do not use a load that generates surge voltage.
A Dimensions except A, L and L1 are the same as rod side flange style.
It is an assembly of a piston and a gasket (KSYP-13).
lrlA |.25N/A r{/A.1 3 .35 t ( l{/A 13.9 or.
Proper auto switch mounting positions (Series CE1) (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 Contact protection box internal circuits 41 47.5 55.5 79.5 82.5 86 D-A7H, A80H, A73C, A80C, D-F7, J79, F7V, J79C 4.5 13.5 17.5 39.5 44.5 42 Choke coil OUT Brown [Red] CD-P11 38 44.5 52.5 76.5
Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.
Recommended pneumatic circuit for the CKQG/P series The following is an example of a basic meter-out control circuit for operating a cylinder using an air filter, a regulator, a solenoid valve and a speed controller. 7) It is possible to use the pneumatic circuit shown below. However, unlock the cylinder before operating.
Refrigerant R134a (HFC) IDU E Drainage is discharged by controlling a solenoid valve with a timer. A strainer for solenoid valve protection and a stop valve are also included. (The external dimensions are the same as the standard product.)
flow rate of 14.1 scfm [400 L/min] (ANR) is P1 29 psi (0.2 MPa) for a 4 orifice and P1 84 psi (0.58 MP)a for a 3 orifice.
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
When using a stopper cylinder for intermediate stopping of a load connected directly to a cylinder, etc. The operating ranges shown in this catalog apply only for stopping of a pallet on a conveyor. When using a stopper cylinder to stop a load connected directly to a cylinder, etc., the cylinder thrust will become a lateral load.
D-M9 A/D-M9 AV (With indicator light) D-M9NAV V A B 9 M D A B 9 M D A N 9 M D D-M9PAV D-M9PA Auto switch part no.
B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.
Mineral oil A A A C A A 18 Sodium hypochlorite (2%, Room temperature) A C D A D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B D A A B 23 Unless noted otherwise, the solution concentration is in a saturated state.
7 i o A A' Cylinder tube sectional view A-A' !0 !1 Parts list No. q w e r t y u i o !0 !1 !2 !3 No. !4 !5 !6 !7 !8 !
B A HS HS B A B A 075, 106 HS B A B A 150, 200, 250, 300, 400 Note) Figures in the table below are references for auto switch mounting positions in the stroke end detection.