40 50 63 Refer to page 12-13-1 for further information on other auto switches.
If the drainage is not discarded properly, it will flow to the secondary side. 4.6-13 Series AMD Made to Order Specifications Please contact SMC for detailed specifications, dimensions or delivery. Order Made 2 With IN-OUT Flange 1 With Pressure Differential Gauge (GD40-2-01) A pressure differential gauge can be installed in the body to check the life of the filter element.
Soft nylon Polyurethane KAH23-M5 17 8.5 14 13 2.1 M5 X 0.8 M6 X 1.0 7 17.5 12.5 8.5 3.4 2.9 4 3.2 1 8 KAH23-M6 KAH23-U01 8 10 17 KAH04-M5 M5 X 0.8 M6 X 1.0 9.5 14 13 2 4 4 8 KAH04-M6 17.5 4 1 8 18.5 13.5 KAH04-U01 5 14 10 10 16 5.6 5.6 1 4 KAH04-U02 16.5 10.5 10 18.5 KAH06-M5 M5 X 0.8 M6 X 1.0 15 14 4 4 11.5 3 10 KAH06-M6 19 1 8 14.5 KAH06-U01 5 12 6 19.5
side 1 2 3 4 5 D side VQ 6 barb fitting 3 (EXH) port VKF (18) 12 VQZ 7 3.5 5 5 3.2 3.5 VZ P = 7.2 12.8 n-3.2, 4 barb fitting 2 (OUT) port VS VFN Dimensions Formulas: L1 = n x 7.2 + 14.8, L2 = n x 7.2 + 18.4, n: Stations (maximum 20 stations) n L 12 101.2 104.8 19 151.6 155.2 2 29.2 32.8 3 36.4 40 4 43.6 47.2 5 50.8 54.4 6 58 61.6 7 65.2 68.8 8 72.4 76 9 79.6 83.2 10 86.8 90.4 11 94 97.6 13
Grommet (G), (H): V11 24(A)-G H-M5 13.1 (Light/Surge voltage suppressor) 5 + 13 15.5 3 13 3 28.5 [32.4] 10 G: Approx. 300 H: Approx.600 (Lead wire length) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 30.9 [33.1] 25.1 11.4 5.7 5.7 5.7 2 1 7 5 9.5 5 19 (Piping
IP40 compliant Name plate [-N] VVQ1000-N-Stations (1 to max. no. of stations) Direct EXH outlet with built-in silencer [-S] Blanking plug KQ2PExhaust port 1 2 3 4 5 9 8 7 6 IP40 compliant 2-2-13 13 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-2-14 14 For details
(Values at the initial period) Solenoid Specifications Base mounted 13 24 SY1 A 13 24 Series SY1 Grommet (G)/(H), L plug connector (L) M plug connector (M) Electrical entry Coil rated voltage (V) DC 24, 12, 6, 5, 3 AC 50/60 Hz 100, 110, 200, 220 JIS Symbol SY113 4 (A) SY123 4 (A) 10 to +10% Allowable voltage fluctuation Power consumption (W) DC 0.75 W (With indicator light: 0.8 W) (A) 2
Furthermore, use the special floating brackets (XC57) which have been provided for the NCY3B series (page 13). Disassembly & Maintenance Warning 1. Use caution as the attractive power of the magnets is very strong.
2 8 0 0.05 3.5 0 0.03 3.5 0 0.03 MHT Open: 22 Closed: 14 MHY 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) MHW -X 15 15 MRHQ MA D6 5 5 6 499 Series MHR2/MDHR2 Nominal Size 20 Without auto switch : MHR2-20R 57 54 3 x M4 x 0.7 thread depth 8 B MHR2-20E Port Location P.C.D.36 (Mounting thread) 60 120 14 120 A C 45 M5 x 0.8 M5 x 0.8 Finger closing port Finger opening port 13
Description Note Material Material Note High carbon chromium bearing steel Aluminium alloy Hard anodized Body Needle roller 1 11 Nickel plated Stainless steel Heat treatment Finger Magnet 2 12 Piano wire Zinc chromated Stainless steel Piston N.O. spring 3 13 Electroless nickel plated Brass Stainless steel Nitriding Lever shaft Exhaust plug 4 14 Resin Stainless steel Magnet holder Exhaust
Dimensions page 13 (Single unit) 9 Series VXK21/22/23 For Steam /Single Unit Model/Valve Specifications N.C. N.O. Passage symbol Passage symbol 2 2 1 1 Normally Closed (N.C.) Normally Open (N.O.)
Refer to back page 50 for Safety Instructions and pages 13 to 17 for Fittings and Tubing Precautions. KA KQG2 Caution KG 1. Tightening of M3/M5 Threads 1) Tighten a barb fitting by hand, and give it an additional 1/6 turn with a wrench. 2) Tighten a barb elbow by hand, and give it an additional 1/3 turn with a wrench.
Description Note 1 Magnet 13 Hard anodized Aluminium alloy Nickel plated Body MHF 2 Steel balls 14 Clear anodized Aluminium alloy High carbon chromium bearing steel Piston 3 Wear ring 15 Heat treatment Stainless steel Synthetic resin Joint MHL 4 12: Roller Heat treatment Stainless steel High carbon chromium bearing steel Guide rail 16 5 16 to 20: Parallel pin Heat treatment Stainless steel
A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19
4 14-13-13 4 Series ALD600/900 ALD600-06 to 10, ALD900-12 to 20 D.P. Lube Related Products: Strainer At the terminal of an air pressure line in which a D.P. Lube is used, install a strainer (filtration rate of 5 m) upstream with a metal seal solenoid valve, which is susceptible to dust. Float switch mounting position Mounting orientation is upward.
Tube size 100 O.D. 6 I.D. 4 14-13-10
(With washer) M5 x 45 M6 x 53 Gasket AXT500-13 AXT510-13, VER4-13 VER4-3P Feed back plate Option Model VER2000 VER4000 Spacer type regulator (B port regulator) ARB310-00-B ARB210-00-B Can be made into manifold with series VV72.
Note 2) O-ring e is included with manifold valve r. 17-2-18 13 Series VCA Direct Operated 2 Port Solenoid Valve For Air Manifold Option Parts Blanking plate assembly (VCA20) VVCA20 4A This is used when a blanking plate is mounted on a manifold as preparation for a planned valve installation.
Large flow filters should be used, especially in dusty locations. 13-1-5
Refer to pages 1315-3 to 13-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 13-1-5 for Precautions on every series. Air suction filter Air suction filter Mounting Vacuum line Vacuum line Construction Warning 1. Be extremely careful with the piping connection screw seal to prevent leakage.