Actuation: Normally Open, Body: Body Ported, Port Size: M3 x 0.5, Bracket: w/Bracket
Actuation: Normally Closed, Body: Body Ported, Port Size: M3 x 0.5, Bracket: w/Bracket
Actuation: Normally Open, Body: Body Ported, Port Size: M3 x 0.5, Bracket: -
Actuation: Normally Closed, Body: Body Ported, Port Size: M3 x 0.5, Bracket: -
Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: CM1 (CC-Link Ver. 1. 10), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable
Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 25: 6mm, Size 32/40: 8mm), Stroke: 400mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable:
Model Screw size Max. tightening torque [Nm] LEPY6 M3 x 0.5 0.9 LEPS6 LEPY10 M4 x 0.7 1.4 LEPS10 It may damage and malfunction. If the operation is interrupted or stopped during the cycle: When the pushing operation command is output immediately after restarting the operation, the direction of movement depends on the position of restart. Side mounting (Body tapped) 2.
O-ring NBR 8 Spring Stainless steel 9 Pin Stainless steel 3 Pinch Valve LPV Series Dimensions Light position (Option) 24 Lead wire length Grommet type (Option) 73 Lead wire length 73 5 Panel thickness: 3 mm or less 83.1 2 x 2.7 Mounting hole thread size: M2.5 Proper tightening torque: 0.25 to 0.35 Nm 19.5 L1 7.45 L2 26.8 20.3 D 19.5 Recommended panel hole dimensions for valve mounting 2 x M3
MACM6 X114 118 125 125 97 113 33.8 53 28 33.3 30 43 X115 59 6 98 60 X116 57 4 60 MACM10 X114 185 197 198 11 152 182 18 53.8 77 31 24 13 0 53.3 50 70 X115 83 6 108 X116 81 4 5 Centering Unit MACM Series Dimensions P: Port side photo sensor mounted type B: Port back side photo sensor mounted type Mounted example of EE-SX671 made by OMRON P: Port side photo sensor mounted type 4 19 2 x M3
Model Screw size Max. tightening torque [Nm] A [mm] L [mm] EQFS16 M3 0.6 3.5 23.5 EQFS25 M4 1.5 4.5 24 EQFS32 M5 3.0 5.5 30 EQFS40 M6 5.2 6.6 31 Body mounting Maintenance Warning Body mounting reference plane For housing B bottom Maintenance frequency Positioning pin (Reference plane) Perform maintenance according to the table below.
Required ventilation rate [m3/min] Model Heat radiation amount [kW] Differential temp. of 3C between inside Differential temp. of 6C between inside and outside of installation area HRR010-A Approx. 2 40 20 HRR012-A Approx. 2 40 20 HRR018-A Approx. 4 70 40 HRR024-A Approx. 5 90 50 HRR030-A Approx. 6 100 60 HRR050-A Approx. 10 140 70 and outside of installation area Voltage dV dt = Voltage
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Rated Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: R (Surge Suppressor Non-polar), Manual Override: None, Port Size: M3 (Body Ported M3X0.5)
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateOption80.18
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateOption80.18
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22
m (95% filtered particle size)Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)PolycarbonateStandard250.22