Mounting frame (Option: Refer to page 11, Accessories.) 12 Air Cooled Aftercooler Series HAA Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa at 0.7 MPa from the table and convert P1 to 0.3 MPa.
VVZ200-32A-11 pc. VVZ400-32A-11 pc. Caution Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
HAA7-06 HAW2-04 AT6C-04 AFF2B-03 IDF1D-1 AM150-03 AMD150-03 1.5 0.2 HAA7-06 HAW2-04 AT6C-04 AFF2B-03 IDF2D-1 AM150-03 AMD150-03 2.2 0.3 HAA7-06 HAW7-06 AT6C-04 AFF2B-03 IDF3DAM150-03 AMD250-03 3.7 0.5 HAA7-06 HAW7-06 AT6C-04 AFF4B-03 IDF4DAM250-03 AMD250-03 5.5 0.7 HAA7-06 HAW7-06 AT6C-04 AFF4B-04 IDF6DAM250-04 AMD350-04 7.5 1.0 HAA15-10 HAW22-14 AT11C-06 AFF8B-04 IDF8DAM350-04 AMD350-04 11
precautions on every series. 14-20-22 2 Micro Mist Separator Series AMD How to Order AMD150 to AMD850 AMD 250 03 J B Body size Option 1 4 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard Standard Standard J Drain guide B female thread R IN-OUT reversal direction Accessory (Option) Symbol Description Bracket T Element service indicator Nil B 3 4 650 1 850 11
R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.) R 3/8 x 100 M16 x l 250 M16 x l 300 M24 x l 500 M16 x l 500 Anchor bolt (4 pcs.) Note 1) Manufactured upon receipt of order Note 2) The accessories should be mounted by user.
AM Misc. 14-18-11 12 Series IDUS/IDFS Specific Product Precautions 2 Be sure to read before handling. Protection Circuit Time Delay for Restarting Caution Caution When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. Allow at least three minutes before restarting the dryer.
As a rough guide, tighten the screw an additional 90C after feeling a tight resistance. 4.3-11 Lever Detection Switch (Proximity Switch) Mounting Position Proximity Switch Specifications/Manufacturer: OMRON Co. Ltd. E2E-X1C1 E2E-X2D1-N Model no.
4 6-14-10 11 Series NCM Construction: Single Acting, Spring Return t y q !1 !2 e r !0 w o CJ1 CJP CJ2 CM2 CG1 !
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data 8-16-11 11 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F 10, 15, 25 How to Order CY1F R 10 300 F9BW Number of auto switches Magnetically coupled rodless cyinder, low profile guide type Nil S n 2 pcs. 1 pc. n pcs
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15, Closed Dimension L2(mm): 11, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 11, Environment, Applications: Dust Resistant / Drip-Proof, Additional Function
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15, Closed Dimension L2(mm): 11, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 11, Environment, Applications: Dust Resistant / Drip-Proof, Additional Function
Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, front and rear
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, AIR CUSHION, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, H5, 20MM CM2 CLEAN-ROOM, .89286 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, CLEAN ROOM, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, H5, 20MM CM2 CLEAN-ROOM, .76736 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, CLEAN ROOM, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, H5, 20MM CM2 CLEAN-ROOM, .82305 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RND BODY, CLEAN ROOM, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, H5, 20MM CM2 CLEAN-ROOM, 1.10231 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 20MM CM2 CLEAN-ROOM, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, H5, 20MM CM2 CLEAN-ROOM, 0.73486 lb
Magnet: D (Built-in), Type: Pneumatic, Mounting: B (Basic), Bore: 20mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Leadwire or Prewired Connector: Z (5m)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com