Piping: Base Mounted Common SUP Individual EXH, Stations: 8 Stations, A B Port Size: 1/4" One-touch Fitting
Piping: Base Mounted Common SUP Individual EXH, Stations: 8 Stations, A B Port Size: 1/4" One-touch Fitting NPTF
Piping: Base Mounted Common SUP Individual EXH, Stations: 8 Stations, A B Port Size: 5/16" One-touch Fitting
Piping: Base Mounted Common SUP Individual EXH, Stations: 9 Stations, A B Port Size: ø6 One-touch Fitting
Piping: Base Mounted Common SUP Individual EXH, Stations: 10 Stations, A B Port Size: 1/4" One-touch Fitting NPTF
Piping: Base Mounted Common SUP Individual EXH, Stations: 11 Stations, A B Port Size: ø6 One-touch Fitting
Piping: Base Mounted Common SUP Individual EXH, Stations: 11 Stations, A B Port Size: 1/4" One-touch Fitting NPTF
Piping: Base Mounted Common SUP Individual EXH, Stations: 12 Stations, A B Port Size: 1/4" One-touch Fitting NPTF
Piping: Base Mounted Common SUP Individual EXH, Stations: 20 Stations, A B Port Size: 1/4" One-touch Fitting NPTF
3.5.2 Precautions for communicating . 3-4 3.6 Setting method . 3-5 3.7 Communication sequence . 3-7 3.8 Message configuration . 3-7 3.8.1 Message frame . 3-7 3.9 Function code . 3-9 3.10 Checksum calculation method . 3-9 3.10.1 LRC(ASCII) . 3-9 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code: 04 Reading multiple registers .3-12 3.11.2 Function code: 06
Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 1 : Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.
How to Order FH100 06 0 0 0 P 005 Table1-7 Made to Order Symbol Made to Order Nil None (Standard) Table1-5 Element X0 Non-standard filtration equipped Symbol Element P Paper M Micromesh Note) The non-standard filtration is for micromesh elements only.
Mounting/ Piping Equivalent tightening torque [Nm] KF 04 1.5 to 2.0 2 to 7 KF 06 1.5 to 2.0 3 to 8 KF 08 1.5 to 2.0 4 to 9 KF 10 1.5 to 2.0 6 to 9 KF 12 1.5 to 2.0 9 to 12 KF 04 1.5 2 to 4 KF 06 1.5 4 to 6 KF 08 1.5 6 to 9 KF 10 1.5 10 to 12 KF 12 1.5 10 to 12 Sleeve material Fitting size Appropriate tightening rotations Nylon 66 C2700 2.
Refer to pages 15-8-3 and 15-8-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-10-1 2 Series ASP How to Order ASP 3 30F 01 06 S Pilot check valve With seal Body size Applicable tubing O.D.
10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
Description ARJM104, 6, 10 Manifold base How to Order ARJ1020F-M5-06 ARJ1020F-M5-04 M5 ARJ 20 10 F 04 1 Option Miniature regulator 1 Set at 0.2MPa Port size Only the adjusting spring is different from standard.
VFN 1 4, 3 8, 1 2 64 64 65 70 1 136 35 9 64 54 19 32 50 50 118 96 120 60 7 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 133 96 140 66 9 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 64 50.8 163 196 68 60.5 1 2, 3 4 4-16-7
The load ratio is obtained by the following formula: ((Load weight x 9.8)/Theoretical output) x 100% Conditions Base piping Series CJ2 Series CM2 Series MB, CA Series CS1 T0604 x 1m Tube x Length Speed controller Silencer Tube x Length Speed controller Silencer Tube x Length Speed controller Silencer AS3001F-06 AN200-KM8 VQC1000 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 VQC2000 AN200-
VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 Pipipng direction VHS500-06 VHS501-06 SA Right IN1 (P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2) Weight (kg) VA 1 (P) 2 (A) 21 105 76 54 35 35 57 93 2 (A) 3 (R) SA 0.25 0.34 Left or right to the front face of the handle.
Y200-A Y300-A Y400-A Y500-A Y600-A Applicable air preparation equipment AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A VHS20 VHS30 VHS40 VHS40-06 VHS50 Note) VHS50 can be connected to AC55 and AC60. Spacer IN OUT Spacer with bracket 1