SMC Corporation of America
Elite Part Number Search
Search Results "IS10T-40-N04-LP-D"

A B C D E F G H I J L M Part no.

1 1 DO DIN terminal, without connector 70 1 4 11 4 G Grommet, Lead wire length 300 mm 1 H 50 70 90 Grommet, Lead wire length 600 mm 11 4 90 2 E Grommet terminal 2 T Conduit terminal D DIN terminal Body ported VEX3 12 0 01 5 D B Base mounted VEX3 22 0 01 5 D B Option Operation type (Only bracket or foot may be mounted.) 0 1 2 Air operated External pilot solenoid Internal pilot solenoid Nil

fiber reinforced urethane hose) (mm) H2 Width across flats D Applicable hose I.D.

Auto switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9N-5 D-M9P-5 Electrical entry direction In-line Wiring 3-wire Output NPN type PNP type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at

Air Cylinder Standard: Double Acting, Single Rod 40, 50, 63, 80, 100 Series CA2 RoHS How to Order L 50 100 CA2 Z D 50 100 M9BW N W Z With auto switch CDA2 Made to Order For details, refer to the next page.

NBR JIS B2401G35 1 pc. u 4.6-30 Series AMF Dimensions: AMF150 to AMF350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4,3/8 1/4, 3/8 5.5 6 6 7 7 139 152 158 184

5 Cylinder: Standard/Non-rotating Type Double Acting, Single/Double Rod Series C76 32, 40 How to Order CJ1 C Double acting Single rod K R2 76 J D E C A 32 100 CJP CJ2 C Double acting Double rod W 76 D E 32 100 C JJ B CM2 Auto switch mounting type CG1 Rail mounting Band mounting A B Built-in magnet MB None Built-in magnet Nil D Applicable auto switches and bands are shown on pages 6-10-45

. -3- 1Specification 1.1 How to Order L E G 32 M D G B 30 C R1 C5H73 Size Motor type Motor mounting position Bearing type 25 32 40 Symbol Motor Compatible Nil Top mounting M Sliding bearing controller D In-line JXC5H JXC6H JXC9H JXCPH JXCEH High performance G Battery-less absolute Step motor 24 VDC Lead [mm] Actuator cable type/length [m] Symbol LEG25 LEG32/40 Robotic cable[mm] 6 8 Nil None

Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver Applicable Stroke Table 4 )Standard DProduced upon receipt of order Stroke (mm) Model 200 400 300 500 600 700 800 900 1000 1200 1500 LEJS40 LEJS63 ) ) ) D D ) ) ) ) D D D D ) ) D ) D D D 4: Strokes other than those shown above are produced as special order (1 mm increments).

D-DN This catalog is printed on recycled paper with concern for the global environment.

Blanking plug KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 L Dimensions (mm) A Applicable fitting size d Model A L D KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 3.2 6 8 10 12 31.5 32 35 39 43 3.2 4 6 8 10 16 16 18 20.5 22 D L DIN rail AXT100-DR-l 7.5 As for l, enter the number from the DIN rail dimensions table.

IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC

Output Power Current Load Load Current Applicable voltage consumption voltage current leakage load drop D-M9N D-M9NV D-M9NW D-M9NWV NPN DC28V type or less At 10mA DC512 0.8V or 100A or Relay 10mA 40mA less less at PLC 24V or less or less IC circuit D-M9P D-M9PV D-M9PW D-M9PWV DC24V (4.5 to 28V) At 40mA 2V or less PNP type D-M9B D-M9BV D-M9BW D-M9BWV DC24V DC24V 2.5 to 4V 0.8mA or less (DC10

~ 140OF Lubrication Not Required (Pre-Lubricated at Factory) Rod End Thread Male Thread/Without Thread Type Of Mounting Nose, Flange, Foot, Clevis, Trunnion H O W T O O R D E R NCJP P I N C Y L I N D E R-D O U B L E A C T I N G D Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service AUTO SWITCH SPECIFICATIONS L D-90 D-97 D-90A D-93A Switch Model

D) In the state of C), adjust shim w so that the arm side block contacts the workpiece.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.

In the actual setting, determine the actual operation of the auto switch and adjust the position. 14 The amount of protrusion of the auto switch W Mounting Basic styleFlange styleFoot style D-M9 D-M9V D-A90 D-A93 D-M9W D-M9WV D-A96 D-A9V W 4 6 4 6 6 4 2 4.5 10 2.5 0.5 0 1 16 2.5 0.5 0 1 Mounting Clevis styleTrunnion style D-M9 D-M9V D-M9W D-M9WV D-A9 D-A9V W 4 6 1 0 10 0 0 16 0 0 * Zero

Internal Circuit Amplifier unit (with sensor unit) Sensor unit D-RPK Model D-7K D-RNK Applicable sensor unit D-F7K, D-Y7K Vsw (Brown) Application For relay and PLC Switch main circuit Power supply voltage 12 to 24 VDC Current consumption 40 mA or less GND (Blue) SOUT 1 (Black) Output specification NPN open collector Two outputs PNP open collector Two outputs Detective sensor SOUT 2 (White