SMC Corporation of America
Elite Part Number Search
Search Results "CDBM2B25-200-WL-M9PSAPC-C"

Air operated External pilot solenoid Selection procedures Table q Applicable fluid check list Body material Seal material BC6: Standard Aluminum: L Stainless steel: S NBR : A FPM : B EPR : C NBR : A FPM : B EPR : C NBR : A FPM : B EPR : C Fluid Fluid Air (Standard, Dry) Low vaccum (1 torr) Refer to Table q to check that the desired fluid is applicable.

5 ENC c Encoder connector (16 pins) Axis 3: Connect the actuator cable. !6 MOT c Motor power connector (6 pins) !7 ENC v Encoder connector (16 pins) Axis 4: Connect the actuator cable. !8 MOT v Motor power connector (6 pins) !

5 ~ 60C / 40 ~ 140OF Rotation Angle 90O, 180O, 270O Seal Material Buna N Drive Shaft Double Shaft, One side with key and groove, other side is a square shaft Maximum shaft loading and kinetic energy Type Fr (N) Fs (N) E max (Nm) NCRB50 250 200 0.084 NCRB80 500 500 0.040 NCRB100 600 550 0.061 D I M E N S I O N S (I N C H) NCRB50~100 H O W T O O R D E R NCRB R O TA R Y A C T U AT O R NCRB

Memory map of output data Data (2 byte) Output area Branch connector (OUTPUT) MSB LSB MSB LSB 15 8 7 0 byte (d) byte (d+1) Word(c) COM A byte (d+2) byte (d+3) Word(c+1) COM B byte (d+4) byte (d+5) Word(c+2) COM C byte (d+6) byte (d+7) Word(c+3) COM D : : (c, d=0 to) NOTE Read carefully the user manual of PLC which is used as a master.

A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.

(between FE and all accessible terminals) Insulation resistance 10 M ohm or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z (complies

Auto switch mounting surface Bore size (mm) 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 Two kinds of auto switch mounting brackets are used as a set.

U U M E J E C T O R D I M E N S I O N S W I T H VA LV E A N D VA C U U M S W I T C H W I T H V A LV E S A N D S W I T C H (N)ZM HK5LZ V O LTA G E 5 24VDC 6 12VDC N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm V A C U U M S W I T C H Nil Without E15L Solid State (NPN) E55L Solid State (PNP) M21L Reed M15L Non-Contact S Y S T E M C I R C U I T Supply Exhaust P O R T T H R E

How to order L E C C G 1 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions 70 - (3) Cable between branches (between the branch connectors) i. How to order L E C C G 2 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8.

IY-G02 CD-MU02 CD-MU03 CD-MU04 Applicable retaining ring C-type 8 for shaft C-type 8 for shaft C-type 10 for shaft C-type 10 for shaft CDH10 (mm) CJ 7 10 10 CI 17 22 27 CH 11 13 13 CF 4 7 10 CE 3.5 3.5 3.5 CB 23 27 31 CA 53 67 85 Size 25 32 40 Part no.

Contact materials Aluminum, Polyacetal, NBR, SUS Accuracy related to temp Indication accuracy: +/0.2 C. Stability: +/0.1 C Model No.

u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l e C u s h i o n s M a i n t e n a n c e I n s p e c t i o n P e r i o d i c i n s p e c t i o n D i sassem ble and reassem bl e C a u t i o n o f d i

without prior notice and any obligation on the part of the manufacturer. 2018 SMC Corporation All Rights Reserved VK300-OMH0002-C

OFF ON OFF Point input B OFF Point input C Time chart OFF Point input D ON Emergency stop input + OFF Actuator speed OFF Alarm reset input Bank input 1 OFF Bank input 2 OFF Point output A OFF Bank input 3 ON OFF OFF Point output B OFF Point input A ON OFF Point output C OFF Point input B OFF Point output D OFF Point input C ON Alarm output OFF Point input D ON READY output ON Emergency stop

Lead wire color (grommet) Voltage Color SOL 100 VAC Blue Cylinder Xa Xb Xc Yb Ya Mode 200 VAC Red Upward High speed a DC Red (+), Black () Low speed b Downward High speed c How to use the needle Low speed d Rotate the needle clockwise to close, and counterclockwise to open.

Only when output 1 and 2 are in the ON state, and C turns ON, will output 3 turn ON. If either A or B is turned OFF , output 3 will not be turned ON, even if C is turned ON.

Stations 1 station MADE IN JAPAN C US TYPE1 R EX500-IE1 (PNP) 1 24VDC/60mA/IP65 8-point integrated type, M8 connector, PNP specifications C US TYPE1 R EX500-IE1 (PNP) 24VDC/60mA/IP65 TYPE1 EEX500-IB1-M6 1 set EX500-IE1 4 sets EX500-IE3 2 sets 24VDC/60mA/IP65 MADE IN JAPAN C US TYPE1 R EX500-IE1 (PNP) MADE IN JAPAN C US TYPE1 8-point integrated type, M8 connector, NPN specifications R MADE

Solenoid Pilot ODerated Series: NVJ3OO t_l f ;+;,a"ten"tdPit.top"[t.o-Serie-f,tV-.t-SOOO] iMKx;;*.Ki -t witrr-SuigJv.lt g" --lzvo-c-1 rw I t l r v n c i l i o l 5 w t t r12V0C 1l i0.r5w)i l e v P { a I 6VDC tl sVDC I 1W I NVJ100: Can be used for vacuum application. NVJ300: jSuppressor L \_l_, ! 1 r-, Diodel ;lCoil I sru"o !