Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation Manual
VXZ2230 VXZ2232 VXZ2240 VXZ2242 VXZ2350 VXZ2352 VXZ2360 VXZ2362 H Y F X E W D U V C S T B K R A J N Q N 79.5 87.5 101.5 106.5 L 108 117 130 135 1 4 3 8 , 28 35 43 45 26 30 38 43 14 17 22 22 7.5 8.5 9 9 24 33 42 47 1.6 2.3 2.6 2.6 22 28 36 42 5.5 6.5 6.5 6.5 40 52 65 70 6 7 7 7 11 14 18 21 93 102 115.5 120.5 25 25 28 28 89 97 112 117 67 75 87 92 50 63 80 90 23 23 25.5 25.5 35 35 40 40 25.5
SY114/SY124, SY114A/SY124A only. 2.1-6 Series SY100 Construction SY114, SY114A (A) 2 3 (R) 1 (P) q y e r w i SY SYJ VK VZ VT VT VP A R P o u t !0 !1 VG VP VQ VQZ Part No.
Dimensions (mm) Electrical entry A B C D E G H J Z Model Grommet Conduit DIN connector Conduit terminal Q R S T U V W N X Y VV2CL2 49 20 24.5 28 4.5 38 17.3 34.5 58 22 45.5 44 43.5 46 58 41.5 66 99 77 VV2CL3 57 25.5 28.5 30 5.5 42 19.3 38.5 68 24 55 45.5 53 48 60 51 68 101 86.5 VV2CL4 57 25.5 28.5 30 5.5 42 20.8 41.5 76 26 62.5 47.5 60.5 50 62 58.5 70 103 94 6 Direct Operated 2 Port for
Min. bending radius (mm) Note) 4 Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) Material Polyurethane Color Black(B), White(W), Red(R), Blue(BU), Yellow(Y), Green(G), Clear(C) Burst Pressure Characteristic Curve and Operating Pressure Note) At a temperature of 20C bend the tubing into a U shape.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual
2 w y r !0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 SUS304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !
B H 10 Y-J010B 15.2 8 21 M4 x 0.7 CP95 SNJ-006B 16 Y-J016B 6 NTJ-006A 16.6 11 21 M5 x 0.8 9.2 8 M6 x 1.0 4 6 5.5 6.4 M3 x 0.5 2.4 SNJ-010B 10 NTJ-010A 12.7 11 M8 x 1.0 4 10 7 8.1 M4 x 0.7 3.2 NDd9 NDH10 R1 NX U1 Part no.
Information that can be copied includes the following: q Pressure set values, w Range settings, e Display Units, r Output modes, t Response times. 5% R.D. Displayed pressure value When CH1 is copied to CH2, CH3, and CH4, information of OUT1 in CH1 will be copied. When CH2, CH3, or CH4 is copied to CH1, information of OUT1 in CH2, CH3, or CH4 will be copied only to OUT1 in CH1.
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 90 lb
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
6ON/OFF valve for oil mist 190 190 t y q t y q 6 6 !0Supply pressure gauge !0Supply pressure gauge R3.5 R3.5 OIL, AIR OIL, AIR Rc1/4 Rc1/4 L L K K C C O O AIR BLOW SUP SUP !1Tank pressure gauge !1Tank pressure gauge 272 272 153 238 153 238 e e 189.5 153 2 189.5 2 u u w r i w r i o o Material Note Main Parts List Part no. Spare Parts/Replacement Parts Part No. No. Description No. Qty.
Working Principle Diagram VY1 Pressure display VBA VBAT Output signal Power supply i Control circuit AP100 Input signal w Exhaust solenoid valve q Air supply solenoid valve e Built-in regulator Built-in regulator EXH Solenoid valve EXH P u Pressure sensor t Diaphragm r Pilot chamber EXH y Air supply valve SUP OUT 959 ITVH2000 Series ITVH2000 Series Linearity Hysteresis 2.5 1.0 Output deviation
---Ht-t---t-+-H I--i IN o I w c.