SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S32-17-M5"

Discrete Input Assembly instance ID Type Description No. of bytes Product model 17 Input 32 Discrete input Points 4 EX250-SDN1 18 Input 32 Discrete input Points 6 EX250-SDN1-X102 -25No.EX-OME0003-H The data format is shown below.

16 11 10 63 13 12 10.5 9.5 18 17 12 11 80 18 14.5 15.5 12 23 19.5 17 13.5 100 18 15.5 15.5 13 23 20.5 17 14.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting. 18 Table 6 (mm) Support bracket other than Center trunnion Number of auto switch mounted Auto switch model 32 40 50 63 80,100 1 switch, 2 switches (Different side, Same side) 10 D-A9 10+

Replacement of seals" on page 17. 2. Air leakage from rod seal Replace the rod seal with a new one. See "3-2. Replacement of seals" on page 17. 3. Insufficient air pressure Supply appropriate pressure. 4. Insufficient flow rate The resistance in the fluid path may have increased due to deformation or foreign matter entering the product. Perform repair or cleaning. 5.

x 2.5 threads through for strokes of 20mm or less. 109 + Stroke 17 + Stroke 17 182 226 2-M24 x 3 effective thread depth 33 143 + 2 (strokes) Width across flats 55 Width across flats 55 M36 x 1.5 M36 x 1.5 21 21 47 47 50 50 64 + Stroke 64 237 + 2 (strokes) 8 Compact Cylinder Series CQ2 Reed Switches/Direct Mounting Type D-Z73/Z76/Z80 Auto Switch Specifications With indicator light D-Z73

Refer to page 17-6-3 for Safety Instructions and Solenoid Valve Precautions. External Pilot Adiabatic Space Caution Caution Piping of pilot port (P1, P2) P1 and P2 piping should be as follows according to the model. There is a space between body and cover (: approximate 1 mm) for adiabatic effect.

17 DIN terminal gasket Rubber mount CR NBR 18 18 DIN connector DIN connector type solenoid coil 19 Clip Stainless steel 20 DIN terminal gasket CR 21 DIN connector 229 Series VCH40 Dimensions VCH41 (N.C.) 1 (56) 41 62 50 17 (44) G1/2 128.5 Applicable cable O.D. 6 to 12 111 1(IN) 2(OUT) 22 Hexagon width across flats 38 98 2 x G3/4 x 16.3 2 x G1 x 19.1 56 VCH42 (N.O.) 1 (56) 41 17 62 50

9 14 Bottom piping adapter PBT 15 O-ring HNBR Fluoro coating 16 Flow adjustment valve body PBT 17 Body Brass Electroless nickel plating 18 Needle Brass Electroless nickel plating 19 O-ring HNBR Fluoro coating 20 O-ring HNBR Fluoro coating @0 PFMB7501/7102 Component Parts !2 !1 !0oi q w e r t y u i !1 !2 No.

Contact SMC beforehand when the product is used for non-industrial applications or is used with fluids other than air. 3 Series NCA1 Cylinder Large Bore 19 18 1 23 17 10 9 12 11 13 8 22 5 Construction 21 7 16 20 2 3 4 14 6 15 Component parts Material Qty.

How to Replace the Components](P16 and 17) and [11. Disassembly Drawing](P18). Problem Countermeasure Possible causes Page for reference Category Failure 1. Clog of the element. Replace the element. As pressure drop is large, fluid does not flow. Flow rate P16 and 17 1. Breakage of bowl seal. Replace the bowl seal.

How to Replace the Components](P16 and 17) and [11. Disassembly Drawing](P18). Problem Countermeasure Possible causes Page for reference Category Failure 1. Clog of the element. Replace the element. As pressure drop is large, fluid does not flow. Flow rate P16 and 17 1. Breakage of bowl seal. Replace the bowl seal.

How to Replace the Components 16 to 17 10-1. Bowl assembly Replacement 16 10-2. Element Replacement 17 11. Disassembly Drawing 18 12. Dimensions 19 -1- Micro Mist Separator Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Note Main parts 16, 17, 18, 19 MHC6-PS Seal kit MHCA2-6 (Short body) Double acting/with fingers closed Single acting Double acting/with fingers open o i e q t !1 !6 w !0 r !4 u !5 !7 y !3 !2 Parts list No. Description Parts list No.

M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.

International inquires: www.smcworld.com 2012 SMC Corporation All Rights Reserved 11-E597 QT -RRD-5M Information AC Servo Motor Driver Series LECSm Power Supply Voltage 100 to 120 VAC 200 to 230 VAC Motor Capacity 100/200/400W Series LECSA (Pulse Input Type/Positioning Type) Incremental Type Absolute Type Up to 7 positioning points by point table Input type: Pulse input Control encoder: Incremental 17

Wiring . 17 3-2-1. Connection Circuit . 17 3-2-2. Wiring of the power supply cable . 19 3-2-3. Ground connection . 19 3-2-4. AC adapter . 19 3-3. Timing chart . 20 4. Function . 21 4-1. Name of Parts . 21 4-2. Emitter maintenance alarm and cleaning . 21 4-3. Replacement of the emitter assembly . 22 4-4. Alarm function . 24 5. Performance . 25 5-1.Basic characteristics . 25 6.

Spacer with bracket Y200T-A Modular adapter E210-U01 Bracket (when control unit fitted) ISA-17 Spacer ISA-18 With O-ring *: When a 2 port solenoid valve is connected to the right. With 2 tapping screws (3 x 8) 16 ISA3 Series Dimensions ISA3-mm (Bracket mounting) 2 1 3 1.8 L1 (23) 7 (41.1) 38 (33.3) 4 77 15 66 H 25.6 11 5.5 When centralized lead wire is used. 17 Pin no.

26.1 18.0 6 15.2 5 16 1 4 1 4 3 8 17.46 17 22.23 36.3 29.5 7 17.9 3 8 22 21 Reference dimensions after NPT thread installation.

No.EX-OMZ0024 PRODUCT NAME Fieldbus system EtherNet/IP compatible SI Unit MODEL / Series / Product Number EX600-SEN7/SEN8 EX600-ED# Table of Contents Safety Instructions 4 System Outline 9 Definition and terminology 10 Assembly 11 Mounting and Installation 13 Installation 13 SI Unit Model Indication and How to Order 16 Summary of Product parts 16 Mounting and Installation 17 Wiring 17 Setting

C on the unit Mark B at cable end Mark A at cable end (1) (2) (3) End plate bracket (EX600-ZMA2) DIN rail mounting groove 1 Intermediate reinforcing brace (EX600-ZMB2) Intermediate reinforcing brace (EX600-ZMB1) Lock screw: No.4-40 UNC DIN rail 2 End plate bracket (EX600-ZMA2) 5 Connector pin assignment Digital input unit 3 4 3 2 1 1 0 EX600-DX B/DX D EX600-DX C 25 24 23 22 21 20 19 18 17

No.PF-OMZ0002-A PRODUCT NAME Digital Flow Switch ( compatible) MODEL / Series / Product Number PF2MC7## Contents Safety Instructions 3 Model Indication and How to Order 11 Summary of Product parts 13 Definition and terminology 15 Mounting and Installation 17 Installation 18 Piping 20 Wiring 21 Outline of Settings [Measurement mode] 29 Flow Setting (set value only) of OUT1 OUT2 [3 step setting