Pilot: Internal Pilot, Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT), Passage: B (Normally Open), Option: E (Continuous Duty), CE Compliant: Q (CE Compliant)

constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamber Note 3)Mounting orientation Note 4)EnclosureWeightRated voltageAllowable voltage fluctuation Note 5)Type of coil insulationPower consumption (When rated voltage is at 24 V)Coil switching noise Note 6)

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter: 2mm , Power-saving circuit available, 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm

constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamber Note 3)Mounting orientation Note 4)EnclosureWeightRated voltageAllowable voltage fluctuation Note 5)Type of coil insulationPower consumption (When rated voltage is at 24 V)Coil switching noise Note 6)

constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamber Note 3)Mounting orientation Note 4)EnclosureWeightRated voltageAllowable voltage fluctuation Note 5)Type of coil insulationPower consumption (When rated voltage is at 24 V)Coil switching noise Note 6)

Symbol: 07R6 (2 Port, N.C.), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)

Symbol: 07R6 (2 Port, N.C.), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)

SI Unit: Q (DeviceNet Omron CompoBus/D), Stations: 6 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting)

Valve Stations: 6 Stations, Port Size: C8 (ø8 One-touch Fitting), Thread: Rc, SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)

Valve Stations: 6 Stations, Port Size: 03 (3/8), Thread: T (NPT/NPTF), SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)

Valve Stations: 6 Stations, Port Size: C10 (ø10 One-touch Fitting), Thread: Rc, SI Unit: Q (DeviceNetâ„¢), End Plate Type: 3 (7/8" Connector Power Supply, Max Supply Current 8A), SI Unit COM: N (-COM)

Symbol: 095R (3 Port, Universal), Function: Y1 (Power-saving Circuit), Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)

Symbol: 092R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 092R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 092R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 092R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 095R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 095R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 095R (3 Port, Universal), Function: Standard, Voltage: 6 (12VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)