an IODD File To set an IO-Link Device by using IO-Link Device Tool, an IODD file for each device must be imported.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
An example of when the SI unit station number is set to 01 is shown below.
Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. 1.
(Element part number ZX1-FE) Verify that the filter gasket is placed properly in the gasket groove before installing an element. Socket Hook Covering Hook 3.
Mounting Direction of Pilot Solenoid Valve Caution When replacing a valve, if an external pilot solenoid valve is mounted in the wrong direction, it may malfunction or leak air. 17-4-10 7 Series VNA Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Construction N.C. N.O.
Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
40 60 80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate L/min (ANR) Flow rate L/min (ANR) SRP1101-01 Conditions/Inlet pressure: 0.5 MPa SRP1-01 Conditions/Inlet pressure: 0.7 MPa 0.25 0.50 0.20 0.40 Outlet pressure MPa Outlet pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate L/min (ANR) Flow rate L/min (
VJ10-20-4A-6 2 pcs. 6 4A 20 VJ10 6 10 15 20 25 30 0.6 m 5A 20 ZS ZF For ZSE3 1 m (For 100 VAC) 1.5 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire with connector part numbers. Ordering example) ZX1051-K15LOECN(-Q) 1 pc. VJ10-20-4A-6 2 pcs.
Note 1) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. Note 2) 200 V type only. 400 V type is CE-compliant as standard. Additionally, combination with option B is not necessary. An earth leakage breaker is equipped as standard.
Compact Electro-pneumatic Regulator Series ITV0 Compact and lightweight electro-pneumatic regulator Compact15mm With a simplified high-density circuit board design, an extremely compact size has been achieved.
This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use valve with DC specifications.
(Element part number ZX1-FE) Verify that the filter gasket is placed properly in the gasket groove before installing an element. Socket Hook Covering Hook 3.
An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.
An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.
Do not transport the product with any part such as an air filter mounted on the fittings at the air inlet or outlet port of the product.
Insufficient fine Select an adjustable speed controller to obtain the adjustment of required piston speed referring to the flow-rate speed controller characteristics curve. 20 - Trouble Major causes Countermeasures Piston speed is 1. Too small Use a valve of a larger size. too slow. directional control valve. Use valves and equipment of an appropriate size. In 2.
Note 7) Products other than Option R are not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately. For [IDF190/ 240D-9-V], it is necessary to purchase the applicable earth leakage breaker for the inlet voltage separately.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
When an amount of steel chips or steel dusts such as sputters of welding accumulate around an actuator equipped with Auto switch, or magnetic bodies (those attracted by magnet) are gathered closely to the actuator, they can weaken a magnet inside the actuator causing inoperativeness of the Auto switch. Do not use the product in an environment where heat cycle exists.