SMC Corporation of America
Elite Part Number Search
Search Results "EXA1-40-EN-ML"

Thomas Liquid Peristaltic Pump Flow Rate: 48 ml / min , 48 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: 1.3 lbs. / .6 Kg Series Configured Datasheet.

Thomas Liquid Peristaltic Pump Flow Rate: 25 ml / min , 25 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: 1.3 lbs. / .6 Kg Series Configured Datasheet.

Thomas Liquid Diaphragm Pump Flow Rate: 1000 ml / min , 1000 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 4.5 m H20 , 4.5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .75 lbs. / .34 Kg Series Configured Datasheet.

The heart of the Air Management System is the hub.  Based on the PF3A flow sensor, the hub generates flow, pressure and temperature data to quantify machine operation.  The standalone or remote hubs can communicate wirelessly with the base units.  The base units have fieldbus communication for connection to the PLC while process data is provided via OPC UA to the customer analytics system

The heart of the Air Management System is the hub.  Based on the PF3A flow sensor, the hub generates flow, pressure and temperature data to quantify machine operation.  The standalone or remote hubs can communicate wirelessly with the base units.  The base units have fieldbus communication for connection to the PLC while process data is provided via OPC UA to the customer analytics system

The heart of the Air Management System is the hub.  Based on the PF3A flow sensor, the hub generates flow, pressure and temperature data to quantify machine operation.  The standalone or remote hubs can communicate wirelessly with the base units.  The base units have fieldbus communication for connection to the PLC while process data is provided via OPC UA to the customer analytics system

The heart of the Air Management System is the hub.  Based on the PF3A flow sensor, the hub generates flow, pressure and temperature data to quantify machine operation.  The standalone or remote hubs can communicate wirelessly with the base units.  The base units have fieldbus communication for connection to the PLC while process data is provided via OPC UA to the customer analytics system

Body Size: 20, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (Units Selection Function)

Body Size: 30, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (Units Selection Function)

Body Size: 60, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (Units Selection Function)

Body Size: 20, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (Units Selection Function)

Body Size: 30, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (Units Selection Function)

Body Size: 60, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (Units Selection Function)

Body Size: 20, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)

Body Size: 60, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)

Body Size: 30, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (Units Selection Function)

Body Size: 20, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: Units Selection Function

Body Size: 30, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: Units Selection Function

Body Size: 60, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: Units Selection Function

Body Size: 20, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: Units Selection Function