width across flats 14 Hexagon width across flats 19 3 3 I 5 5 D C J H I Hexagon width across flats 8 M5 x 0.8 J H F Hexagon width across flats 10 Hexagon width across flats 2 Hexagon width across flats 12 F M8 x 1.25 Y D C Hexagon width across flats 12 Hexagon width across flats 3 2 A B 3 2 A B Dimensions: 10 mm Stroke (mm) B Stroke: 10 mm A C D F H I J Y Model ZPT10F10-B5-A10 10 12 10 12.5
3 O-ring NBR u 15-9-105 Dimensions L4 D3 H (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 A 8 9 9 4.5 10 31 10.3 0.7 27.4 AS220-N01-ST NPT 1/8 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 R 1/8 12 14.3 14.6 7 18 35.6
(inch) Thread UNF NPT Min. hole dia. 10-32UNF L2 A M Part No. H (Hex.)
. 9-1 9.1 Specifications . 9-1 9.1.1 HRR050-A-. 9-1 9.1.2 HRR050-W-. 9-3 9.1.3 Refrigerant with GWP reference . 9-5 9.1.4 Communication specification . 9-5 9.2 Outline dimensions . 9-6 9.2.1 HRR050-A-20. 9-6 9.2.2 HRR050-W-20. 9-7 9.2.3 HRR050-A-40. 9-8 9.2.4 HRR050-W-40. 9-9 9.3 Flow Chart . 9-10 9.3.1 HRR050-A-20/40.9-10 HRR Series HRX-OM-X071 Contents 9.3.2 HRR050-W-20/40. 9-10 9.4 Cooling
size ISO size 2 Series VQ7-8 ISO size 2 0.96n + 0.77 (n: Stations) Max. 10 stations 3/8 1/2 1/2 3/4 3-10-27 28 Series VQ7-8 DIN Terminal Type VV72-2n-3/8, 1/2 118 142 67 9 118 142 9 34 20 2-1/8 14 Indicator light P , R1, R2 port for Rc 3/4 only U side U side 18 R4.5 60(73) P = 56 P = 56 60(73) 23 R4.5 Manual override B PA 18 42 14 1313 B A SMC SMC SMC B B B A PA B PA B A A B PA Courtesy
VFR PA A B VP4 L1 L2 B A A PA VZS A B SMC VFS PA A VS4 B VQ7 PA A L side R side (2n-1/8) EVS 38 D side VFN 3 68.5 (A, B port) 4n-1/4, 3/8 16 120.5 (Single) 44 155 (3 position) 145 (Double) 55 77.5 121 PA 14 PB 12 1 R 3 5 65 54 P 39 (Pilot pressure EXH port) 4-1/8 SMC 21 R2 R1 17 17 (P , R port) 6-3/8 26.5 26.5 L Dimension n: Stations 10 9 8 7 6 5 4 3 2 1 Formula L1 L1 = 43n + 64 494 451
CAT.ES20-174 A Compact Type Dual-Rod Cylinder 15, 20, 25, 32 additionally released. Series CXSJ/6, 10, 15, 20, 25, 32 Series CXSJ/6, 10, 15, 20, 25, 32 Auto switches can be installed from 3 directions.
8.2 16 18 20.5 16 16 18 20.5 17 32 35 39 31.5 32 35 39 3 6 8 10 5 6 8.5 10 When a block disk is concurrently ordered by specifying on the manifold specification sheet, etc., a label will be stuck on the position where block disk is mounted.
11 17.5 1 (Bleed port) VA 1.5 A B M3 x 0.5 (Piping port) 1.5 1.5 33 36 SA Manual override B P R R (35) 7 7 36 (2) VA 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 VM 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14 14 15 (Bracket) VR VH 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 VHS 10 9 36 7.1 2-M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2-3.2 1.5 1.5 22 7 8.2
screw 103.3 (131.5) A 4 SMC 37.6 53.6 B 2 18.5 12 12 e d i s U e d i s D Stations 1 2 3 4 5 6 7 8 n One-touch fitting [3(R), 1(P) port] Applicable tubing O.D.: 10 10 Lead wire length: L0, 0.6 m L1, 1.5 m L2, 3.0 m For top ported R 3 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 62.1 41.7 25.7 39.4 (58) 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 20.9 P 1 P=17.5 48.8 30 7.5 One-touch fitting [4(A), 2(B) port] Applicable
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.
D-Z7m D-Z8m D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10
Minimum Auto Switch Mounting Stroke (mm) Auto switch model D-M9W D-M9A Bore size (mm) D-A9 D-A9V D-M9 D-M9V D-M9WV D-M9AV D-P3DW No. of auto switch mounted 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 2 pcs. 1 pc. 10 10 10 10 10 10 10 5 10 10 10 5 10 5 10 5 10 5 10 5 15 15 10 10 10 10 10 5 15 15 15 15 15 15 15 15 15 15 15 15 5 5 5 5 5 5 5 5 5 5 10 5 10 5 10 5 10 5 10 5 10 10 10 10
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.
As a rule, use electrical wire with a cross sectional area of 0.5 to 1.25 mm2 for wiring. 2. External force applied to the lead wire If an excessive force is applied to the lead wire, this may cause faulty wiring. Take appropriate measures so that a force of 10 N or more is not applied to the lead wire.
10 11 10 D-B5/B64 8 9 10 10 11 11 11 10 D-B59W 13 14 14 14 17 16 18 13 D-H7/H7NF/H7W/H7BAL 4 4.5 5 6 6.5 6.5 7 4 D-H7C 7 9 10 9.5 10.5 10.5 11 8.5 D-A3/A44 9 9 10 10 11 11 11 10 D-G39/K39 8 9 9 9 10 10 11 9 4 D-G5/K59/G5W D-K59W/G5BAL/G5NTL Since this is a guideline including hysteresis, not meant to be guaranteed.
DL DD DA DU DC DX DE DO DR DT DS DH DF B W1 Z A B A + B + 90 CA1-B04 CA1-B05 CA1-B06 CA1-B08 CA1-B10 +0.058 0 11 57 35 65 15 85 10 9 17 8 40 52 60 10 234 10 +0.070 0 11 12 57 35 65 18 85 10 9 17 8 40 52 70 10 261 +0.070 0 13.5 12 60 162 67 40 80 25 105 12.5 11 22 10 50 66 85 10 280 16 +0.084 0 16.5 93 60 100 31.5 130 15 13.5 24 12 65 90 102 12 337 20 +0.084 0 16.5 93 60 100 35.5 130 15 13.5
DL DD DA DU DC DX DE DO DR DT DS DH DF B W1 Z A B A + B + 90 CA1-B04 CA1-B05 CA1-B06 CA1-B08 CA1-B10 +0.058 0 11 57 35 65 15 85 10 9 17 8 40 52 60 10 234 10 +0.070 0 11 57 35 65 18 85 10 9 17 8 40 52 70 10 261 12 +0.070 0 13.5 12 60 162 67 40 80 25 105 12.5 11 22 10 50 66 85 10 280 16 +0.084 0 16.5 20 93 60 100 31.5 130 15 13.5 24 12 65 90 102 12 337 +0.084 0 16.5 93 60 100 35.5 130 15 13.5
Description 136144-S Common supply bushing 136144-K Individual supply bushing Single unit regulator / Port plug for regulator block 136144-S 136144-K Option Description None Oil-free Symbol Nil X17 A-A A A-A A 12 12 10 A A 8 8 15 15 10 516 Regulator Single Unit Type Series ARM10 How to Order ARJ AR425 to 935 Standard Type ARM10 06 B Z 1 q w e r t N AMR 1.