SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-06-DO-00T"

Set up the output points using the internal switches. 3 Display and switch setting cover Switch for 16/32 outputs 128 inputs/128 outputs Number of points Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

List of output mode Do not operate the product outside of the specifications. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Panel Measurement mode Hysteresis mode Mounting screws Press the button for 2 s or longer Switch output Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. 1 s. after This function is to display error location and content when a problem or an error occurs. All indications Instantaneous value indicatio Error Name Error Display Error Type Troubleshooting Method Do not operate outside of the specification.

Do not hold the bellows. Be sure to only hold the valve during reassembly. Pay great attention to mounting the bellow assembly. Otherwise, the bellows might be damaged. > (Note1) Only when disassembling the XLC, apply a 0.2 to 0.4 MPa of pressure to the closed side pilot port. Do not apply pressure to the XLA during disassembly. necessary. (Ensure there are no fibers or dust.)

Note1) To avoid the damage of O-ring and adjustment part, do not turn bypass valve adjusting bolt(13) farther than the point where turning is stopped at both ends. Note2) Do not apply pressure to the operation port during adjustment. Note3) Bypass valve is fully open at ex-factory.

Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within IG 60Hz. -6- 6. Maintenance !

Mounting of fitting assembly Fitting assembly Clip Clip 11 - Caution Environment (1)Do not use the product in an environment where the product is directly exposed to corrosive gases, chemicals, salt water or steam. (2)Do not mount the product in a location where it is subject to strong vibrations and/or shocks. (3)Use this vacuum regulator in a location free from dirt since this product sucks

Caution Food zone Not installable Do not use air grippers in a food-related environment. Splash zone Installable Food zone Food may directly contact with air grippers, and is treated as food products. Splash zone Food may directly contact with air grippers, but is not treated as food products. Non-food zone Air grippers do not directly contact food.

T-slots l Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXP M5 x 0.8 7.4 8.5 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body.

Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, confirm the safety process as mentioned above.

Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, confirm the safety process as mentioned above.

Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be assimilated, which results in the generation of a lateral load that can cause malfunction.

Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a nipple so that no foreign matter will be mixed. For the grease, we recommended using high-quality lithium soapbased grease no. 2. 6.

ZSM PFl Piping IFl Caution qPiping materials Do not mount any equipment or fittings between the switch body and the detection nozzle in order to avoid leaks and pressure drops. Do not use one-touch fittings in applications where these fittings might be exposed to liquid being sprayed onto them.

Tidy Un-friendly What do you think to the manual presentation? ! ! ! Yes Not too bad Unusable Are the explanations understandable? Which explanation was most difcult to understand: . . ! ! Are there any diagrams which are not clear? Yes No If so,which:. ! ! ! What do you think to the manual layout?

Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment. 2. If electric power is shut off while pressure is being applied, pressure will be retained on the output side.

The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases.

Do not drop, dent, or allow excessive impact to cylinder during handling. 5, Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto 3. switch are mounted in parallel. up, although the auto switch will function. Do not exceed specified current or the LED might be damaged and not functjon.

MXS 6 MXS 8 MXS12 MXS16 MXS20 MXS25 4 5 5.5 6 10 13 0.9 0.9 2.1 4.4 4.4 7.4 M3 X 0.5 M3 X 0.5 M4 X 0.7 M5 X 0.8 M5 X 0.8 M6 X 1 Bottom screw Do not rotate Piston rod Precautions for Adjuster Option Stroke adjuster Do not damage. Caution eShock absorber is considered a consumable component. When energy absorption is decreased, replace it.