30 HRLE090-m-20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) M5 R5.5-5 4 cores x 5.5 mm2 30 (4 cores x AWG10) Including grounding cable HRLE090-m-40 3-phase 380 to 415 VAC (50/60 Hz) 3-phase 460 to 480 VAC (60 Hz) M8 R5.5-8 20 An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are
HECR Applicable model Rated current [A] Sensitivity of leak current [mA] Short circuit display method HRS100-A/W-20 30 30 Mechanical button HRS150-A/W-20 40 Earth leakage breaker HEC HEB * 400 V type is equipped as standard. HED * Cannot be selected together with option B1.
25 M10 x 1.25 26 22 19.5 13 10 17 10 9 19 10 45 6 37.5 5.5 10.5 8 30 D32 M10 x 1.25 26 22 19.5 13 12 17 10 9 19 11 45 6 46.5 5.5 10.5 10 30 40 M14 x 1.5 32 24 21 16 14 22 15 10 30 12.5 50 8 56.2 7 13.5 12 39 -X NA NN P RR N S U Z ZZ Bore (mm) 20 M20 x 1.5 1/8 9 146 14 217 226 20 30 Individual -X 25 M26 x 1.5 1/8 9 146 14 221 230 20 34.5 32 M26 x 1.5 1/8 9 159 14 234 243 22 42.5 40 M32 x
25 M10 x 1.25 26 22 19.5 13 10 17 10 9 19 10 45 6 37.5 5.5 10.5 8 30 D32 M10 x 1.25 26 22 19.5 13 12 17 10 9 19 11 45 6 46.5 5.5 10.5 10 30 40 M14 x 1.5 32 24 21 16 14 22 15 10 30 12.5 50 8 56.2 7 13.5 12 39 -X NA NN P RR N S U Z ZZ Bore (mm) 20 M20 x 1.5 1/8 9 146 14 217 226 20 30 Individual -X 25 M26 x 1.5 1/8 9 146 14 221 230 20 34.5 32 M26 x 1.5 1/8 9 159 14 234 243 22 42.5 40 M32 x
Name Lead wire colour Function 1 L+ Brown 18 to 30 VDC 2 N.C.
Bonnet assembly/Part indication number (1) Temperature specifications Indicator Valve size 16 25 40 50 General use Without XLA16-30-1-2 XLA25-30-1-2 XLA40-30-1-2 XLA50-30-1-2 With XLA16A-30-1-2 XLA25A-30-1-2 XLA40A-30-1-2 XLA50A-30-1-2 High temperature Without XLA16-30-1H-2 XLA25-30-1H-2 XLA40-30-1H-2 XLA50-30-1H-2 With XLA16A-30-1H-2 XLA25A-30-1H-2 XLA40A-30-1H-2 XLA50A-30-1H-2 Temperature
-1-2 XLA25-30-1-2 XLA40-30-1-2 XLA50-30-1-2 XLA16A-30-1-2 XLA25A-30-1-2 XLA40A-30-1-2 XLA50A-30-1-2 XLA16-30-1H-2 XLA25-30-1H-2 XLA40-30-1H-2 XLA50-30-1H-2 XLA16A-30-1H-2 XLA25A-30-1H-2 XLA40A-30-1H-2 XLA50A-30-1H-2 63 80 XLA63-30-1-2 XLA80-30-1-2 XLA63A-30-1-2 XLA80A-30-1-2 XLA63-30-1H-2 XLA80-30-1H-2 XLA63A-30-1H-2 XLA80A-30-1H-2 11,2 FKM:No.1349-80[ ]P8 XLA16A-30-1-2-XN1 2 M9
Bonnet assembly/Part indication number (1) Temperature specifications Indicator Valve size 16 25 40 50 General use Without XLF16-30-1-2 XLF25-30-1-2 XLF40-30-1-2 XLF50-30-1-2 With XLF16A-30-1-2 XLF25A-30-1-2 XLF40A-30-1-2 XLF50A-30-1-2 High temperature Without XLF16-30-1H-2 XLF25-30-1H-2 XLF40-30-1H-2 XLF50-30-1H-2 With XLF16A-30-1H-2 XLF25A-30-1H-2 XLF40A-30-1H-2 XLF50A-30-1H-2 Temperature
The dog fitting cannot be attached to the knuckle joint, M6 without tap (rod end bracket symbol I or Y). 20 97 30 42.5 Part no.
For 30 type, common external pilot (on manifold side).)
1 i r P A R For DC: SY100 30 4A For 100 VAC: SY100 30 1A For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A SY100 30 A Lead wire length Nil 6 10 15 20 25 30 50 Without lead wire: (with connector and 2 sockets) 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm 2 Series V100 How to Order Standard type Base mounted V1 4 M 1 5 3 port Port size Nil: Without sub-plate M5
M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13
40 V15 V3 L 1 H V2 2 4 10 30 40 -30 in.Hg to 15 psig -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig -30 in.Hg to 200 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 3000 psig 0 to 4000 psig -0.1 to 0.1 MPa -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa -0.1 to 1.4 MPa 0 to 1.5 MPa 0 to 3 MPa 0 to 7 MPa 0 to 21 MPa 0 to 28 MPa 00
64 74 16 20 22 30 36 46 28 28 28 30 36 46 43.4 48 59.4 71.4 86 105.4 CS1 Up to 300 Up to 300 Up to 300 CS2 Up to 300 Up to 300 Use a thin wrench when tightening the piston rod.
(mm) Female rod end (mm) With air cushion ZZ Bore size H Bore size S A1 GA RA ZZ WH WB WA MM Rubber Air 8 8 12 13 18 18 21 25 87 (96) 102 (114) 102 (114) 13 14 14 15 16 16 19 22 22 26 26 8 9 9 15 (17) 16 (18) 17 (18) 26 30 30 M4 x 0.7 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.5 M10 x 1.5 M14 x 1.5 M16 x 1.5 139 (148) 162 (174) 162 (174) 1.5 3 3 40 50 63 92 (100) 93 (101) 95 (103) 95 (104) 108 (
30 40 48 30 40 48 15 15 20 24 15 20 24 62.5 73.5 72 75 78 76.5 79.5 30 35 35 35 40 40 40 9 9 9 20 22 22 22 24.5 24.5 24.5 8 8 9 14 8 9 14 15 15 22.2 19 15 22.2 19 18 18 22.2 20.6 18 22.2 20.6 6.4 6.4 7.6 6 6.4 7.6 6 27 29.5 29.5 29.5 32 32 32 44 54 52.5 53.5 58 56.5 57.5 30 32.5 32.5 32.5 35 35 35 30.5 40 38.5 39.5 44.5 43 44 2 11 9 9 3 11 Conduit terminal DIN terminal Size Port size P Q
30 30 30 30 30 45 55 68 58 67 73 21 26 32 23.5 28 34.5 46 55 66 59 71 82 34.5 40 46.5 Stroke range Bore size (mm) N NB P S XA XL Y WL WM ZZ M MA MB MC MM 40 50 63 Up to 1000 Up to 1000 Up to 1000 44 50 56 74 83 89 1/4 1/4 1/4 168 183 204 12 16 16 6 6 6 9.5 12.5 15 42 42 52 16 16 16 4 5 5 12 15 15 M6 x 1.0 M8 x 1.25 M8 x 1.25 10 14 14 208 228 254 39 42 52 8-25-17 17 Series MGZ With Mounting
PVC PVC PVC PVC PVC , -10No.PF-OMM0004-D -11No.PF-OMM0004-D N M8 M8 R / ZS-40-K PF3W704/720 4 3X8 ZS-40-L PF3W740 4 3X8 ZS-40-M PF3W711 4 4X10 M8 ZS-40-A 3 m 2 250 L/min PVC 25 A ZS-40-U25 25 A PVC 1 PVC 30 A ZS-40-U30 30 A PVC 1 25 A ZS-40-U25-A 1 M5x80 2 30 A ZS-40-U30-A 1 M5x65 2 PVC 1~2% -12No.PF-OMM0004-D 1 DC+ 2 OUT2 3 DC4 OUT1 M8 IN OUT OUT1OUT2 ON UP ON/OFF SET
A B 3 5.5 7 7 15 60 65 + 45 (n-2) D-H7, D-H7W D-H7F 30.5 28.5 30 30 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) Approx. Hs 30.5 35 40.5 47.5 D-H7C 15 65 10 65 + 50 (n-2) A B Approx. Hs 3 5.5 7 7 n-2 2 D-H7C 31.5 28.5 30 30 15 + 50 ( ) (n = 2, 4, 6...)