Do not operate at pressures or temperatures, etc. beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Contact SMC when using a fluid other than compressed air (including vacuum).

Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed *5 A switch spacer (BMY3-016) is required to secure auto switches.

Do not grip the piping port on the back side or the handles of the panel. 3. Do not pass over bumps, etc., with the casters.

Do not disassemble the product because it may damage the air cushion mechanism. Contact SMC when disassembly or maintenance is necessary . 169

Housing assembly Body Caution M5 hexagon socket head cap screw q M6 special screw (Do not disassemble.) Caution M6 special screw (Do not disassemble.) M5 hexagon socket head cap screw w Fig.1 Caution 1. Before disassembling, be sure to shut off the pressure supply, and then release the residual pressure. 2. After assembly, confirm that there is no fluid leakage.

The pad, mounting nut, fitting, and buffer plate are shipped together but do not come assembled. 86 Thin Flat Type ZP Series Basic Pad Dimensions/Models Single unit 10 to 16 w q ZP UT N 10 7 Model A B Y q Pad dia.

Do not apply load and external force on brake and scale plate. Readjustment for brake and scale plate in normal operating condition is not necessary due to preadjustment prior to delivery. Therefore, do not change the setting on adjustment parts carelessly.

Do not operate Series CS1 at twice the output. CJ1 CJP Applicable Series CJ2 Series Vol. no.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 3 Branch port (COM A to D) 4 Branch port A (COM A) 128 inputs/128 outputs Number of points Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

IO-Link DI DO StandardIO StandardIO 2 0x00 . 9-4 X0 X1 X2 X3 IO-Link 1 2 3 4 IO-Link 2 (I/Q) Bit 1 Bit 3 Bit 5 Bit 7 EX245-LA1 (EX245-LB1 0) 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DO 2 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DI() 9.5.

Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about troubleshooting. 3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Branch port (COM A to D) 8 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

An injury or failure can result. 3 Display LED LED display to indicate the input unit status. 128 inputs/128 outputs Number of points Sensor connector Connector for sensor. 4 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. No.

Set up the output points using the internal switches. 3 Display and switch setting cover Switch for 16/32 outputs 128 inputs/128 outputs Number of points Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

List of output mode Do not operate the product outside of the specifications. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Panel Measurement mode Hysteresis mode Mounting screws Press the button for 2 s or longer Switch output Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. 1 s. after This function is to display error location and content when a problem or an error occurs. All indications Instantaneous value indicatio Error Name Error Display Error Type Troubleshooting Method Do not operate outside of the specification.

Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.

Do not hold the bellows. Be sure to only hold the valve during reassembly. Pay great attention to mounting the bellow assembly. Otherwise, the bellows might be damaged. > (Note1) Only when disassembling the XLC, apply a 0.2 to 0.4 MPa of pressure to the closed side pilot port. Do not apply pressure to the XLA during disassembly. necessary. (Ensure there are no fibers or dust.)

Note1) To avoid the damage of O-ring and adjustment part, do not turn bypass valve adjusting bolt(13) farther than the point where turning is stopped at both ends. Note2) Do not apply pressure to the operation port during adjustment. Note3) Bypass valve is fully open at ex-factory.