No.EX-OML0010CN-C / / EX600-HT1A 2 8 8 9 10 10 11 12 12 13 1. I/O monitor(I/O ) 15 2. Diagnosis Data() 24 3. Sys. Configuration() 27 4. Parameter Setting() 33 5.
No.PF-OMG0010-H PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7##H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Piping 15 Wiring 16 Outline of setting 18 List of outputs 19 Function selection mode 20 F_0 Initialize
No.PF-OMH0003-F PRODUCT NAME 4-channel Flow Monitor (Remote type monitor unit) MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 15 Installation 15 Wiring 16 Outline of setting 19 List of outputs 20 Initialize mode 21 Default
40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMY0001 6. 200 []1 1.5 1 200 FKM 110Pa <> 13 XL-OMY0001 7 7-1. 2 2P5P6 14 XL-OMY0001 7-2 1 2 1 3 1 1 2 4 1 0.4MPa G 3 4 2 XLA-16 2.4mm 7mm -25 3mm 8mm -40 4mm 10mm -50 5mm 13mm -63 -80 6mm 17mm < 2 < 15 XL-OMY0001
40 26 44 21 XLC-40-2 65 171 66 39 11 55 41 67 29 12 XL-OMV0007 5-3.Dimensions Size 50, 63, 80 E C C E E (KF flange) (K flange) Fd Fn D K J H B A G A Unit: (mm) Model A B C D E Fn Fd G H J K XLC-50-2 70 185 79 46 11 75 52 72 29 9 XLC-63-2 88 212 100 55 11 87 95 70 76 33 9 XLC-80-2 90 257 117 65 11 114 110 83 104 39 9 13 XL-OMV0007 6.
Keep the screwdriver away from the auto switch when searching mounting position of the auto switch where it operates correctly. 12 - 2. Keep a gap wider than the values listed in the table when arranging the magnet grippers side by side or when placing the magnet grippers close to magnetic objects such as iron.
When the load is up to 12 W, use both the Power block and a high wattage load Output block. For low Current Output to connected load (output equipment) or manifold valves using the power supply from the SI unit. EX9-OET1 EX9-OET2 wattage load For high Current Output to connected load (output equipment) using an external power supply.
EX250-SAS3/-SAS7: 8 points EX250-SAS5/-SAS9: 4 points -24No.EX-OMP0025-A Fault No.12 Problem Possible cause Investigation method Countermeasures Tighten the screws while holding the SI unit and the input block so that there is no gap between them.
No.EX-OML0011-C PRODUCT NAME Fieldbus Device Handheld Terminal MODEL / Series / Product Number EX600-HT1A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Names and Functions of Product 8 Definition and terminology 9 Mounting and Installation 10 Precautions before mounting 10 Wiring 11 Setting and Adjustment 12 Basic operation 12 Mode selection 13 1.
Follow the items below to prevent the generation of abnormalities in the product. 41 - Doc. no. ZQ-OM00801-D 1. Use voltage within the rated voltage. 2. Do not lubricate the supply air. 3. Do not directly apply liquid such as water on the body. 4. Do not apply a strong impact. 5. Do not mix drain or dust in the supply air. 6.
When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures (such as the installation of a cover or the restricting of access to the product) to prevent potential danger caused by actuator operation. 12.
Recommended proper torque Nm Connection threads 1/2 M5 1/8 1/4 3/8 3/4 1 28 to 30 1.5 to 2 7 to 9 12 to 14 22 to 24 28 to 30 36 to 38 Torque 2. Twisting moment or bending moment other than the dead weight of the equipment should not be applied. To avoid damage, external piping should be supported separately from the product. 3.
Piston assembly Valve Valve spring No. 4 5 6 1348104A 1348105 1348109 SUP OUT 2 ARX Series Specialty Regulators Regulator for 290 psi (2 MPa) ARX20, 21 Dimensions Panel cutout dimensions 1.02 (26) R .1 (2.5) SUP OUT SMC K C O P A A L U S H .5 (12) 1.61, 2.13 [41 (K40)], [49 (K50)] 2.13 (54) .98 (25) 1.6 (max. thickness 4.5) 1.73 (44) .21 (5.4) 3.13 (79.5) (when regulating pressure = 3.23
(For type 20, 41, 42 and 45) Pilot pressure range SS5YA Fill the same as SS5Y . 3 5 7 3 5 7 Pilot pressure MPa Specify the part numbers for valves and options together beneath the manifold base part number. (Example) SS5YA5-42-03-02 1 set (Type 42, 3 station manifold base part no.) SYA5140 1 set (Single air operated valve part no.) SYA5240 1 set (Double air operated valve part no.)
3 Stainless steel Spool spring 3.5-41 VZM500 Series VZM500 Basic/VZM550-01-00 JIS Symbol SlA VlA SlA VlA 16N F.O.F. 0.5MPa supply 1mm P.T. 2mm O.T. VM/VR 3mm T.T. VH Roller Lever/VZM550-01-01, VZM550-01-01S JIS Symbol 8N F.O.F. 0.5MPa supply 2.2mm P.T. 4mm O.T. 6.2mm T.T.
PSE ZS-26-J IS ISG Specifications ZSM PSE532 (Low pressure) Model PSE530 (Positive pressure) PSE531 (Vacuum) PSE533 (Compound pressure) Rated pressure range 0 to 101 kPa 0 to 1 MPa 0 to 101 kPa 101 to 101 kPa 10.1 to 0 kPa 0.1 to 0 MPa 10.1 to 0 kPa Extension analog output range Proof pressure 500 kPa 1.5 MPa Applicable fluid Air/Non-corrosive gas/Non-flammable gas Power supply voltage 12
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 Nozzle size Nil 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, MANIFOLD, VACUUM EJECTOR, M02, 41 lb