Metric size 4, 6 Inch size 5/32", 1/4" Port size Rc, NPT 1/8 2 2 VBA 1 1 Pressure gauge port size Rc, NPT 1/8 (Width across flats) 11 M5 x 0.8 (Female thread) 26 VE VY1 26.1 3 R, NPT 1/8 13.6 18.3 G 26.1 PPA AL 14-4-13 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Fittings & Tubing Air Cylinders Rotary Actuators 33.4 32 36 120 120 A C 32 8.5 8.5 Finger closing port Finger opening port M3 x 0.5 M3 x 0.5 9.5 3 x M3 x 0.5 thread depth 6 25 25 M3 x 0.5 Finger closing port P.C.D.24 (Mounting thread) M3 x 0.5 Finger opening port 31 9h9-0.036 0 1 32 5 15 19 10 5 (35) 7 14.5 M3 x 0.5 thread depth 4 6 x M3 x 0.5 thread depth 6 (A, B, C common view) Vacuum suction
UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57 0.38 1.12 1.56 0.25 1.75 1/4 1.75 0.125 0.38 7/16-20 1/4-20 NUC 5/16-18 0.437 Block Mounting Type (in) ZB2 ZB3
Active: Force output mode enabled Inactive: Force output mode disabled 2 Force output 3 Module status SI unit operating condition. 16 In/32 Out Device Operational: Normal operation Displays the communication status of the SI unit EtherNet/IPTM.
(Refer to page 32.) -29No.PF-OMN0012-H c. When accumulated output mode is selected. Selection of accumulated increment or decrement Sub screen Press the or button to select. Press the button to confirm. Move on to the input of set values. -30No.PF-OMN0012-H When accumulated increment is selected. When accumulated decrement is selected.
(See Fig.13) Replacement part: Shock absorber Bore size Part no. 32 RB1007-X225 4050 RB1407-X552 Lever Hexagon socket head set screw Push down Fig. 11 10 - Lever Shock absorber 11.Internal construction 12 16 Push down Replacement Grease applied Approx.5mm Fig. 12 Fig.13 20 11 - 32&50 Component Parts (12&50) 12 - Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81
43 69 77 95 89 106 1 8 1 4 14 8.6 8.6 4 29 32 33 34 1 8
(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE KE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 N AS-FG AS-FG AS-FP AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 542. Use 1/8" tube.
Metric size Inch size Meter-out Meter-in 0 1 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 23 04 06 08 10 12 4 6 8 10 12 With One-touch fitting Stainless steel specifications (SUS303) Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Use 1/8" tube.
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 KE N AS-FG AS-FG AS-FP Note) For applicable tubing O.D. selection, refer to the Model on page 680. Use 1/8" tube.
Symbol 10 10 A8 M8 x 1 10 to 16 13 13 A10 M10 x 1 20 to 32 16 16 A14 M14 x 1 40, 50 20 20 25 25 Vacuum entry port 32 32 40 B5 M5 x 0.8 40 50 50 Material NBR N Pad type Silicone rubber S Ball joint type F Urethane rubber U FKM F Conductive NBR GN Conductive silicone rubber GS Note) Pads are exclusively ball joint type and are not interchangeable with other pads.
WindowsXP (32/64bit) Windows7 (32/64bit) Windows8 (32/64bit) Windows10 (32/64bit) 1) Install Microsoft .NET Framework 4 or later before use. 2) This tool might not operate correctly depending on the security setting of the PC. In that case, disable the security setting temporarily and try to use it again. Applicable products are as follows.
(mm) a = Internal cross section of piping [mm] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4 2.5 4.9 QC = Air consumption required for one reciprocation of Mini-Rotary Actuator [l (ANR)] 6 4 12.6 8 5 19.6 8 6 28.3 6.5 33.2 10 7.5 44.2 12 8 50.3 12 9 63.6 9.2 66.5 16 12 113 12.7 127 16 13 133 16.1 204 21.6 366 27.6 598 Air Consumption
(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit
How to Order J S 32 10-125 Stainless steel type Dust cover material Symbol Nil S Material Fluoro rubber Silicon rubber Applicable cylinder bore size (mm) Nominal thread size Applicable cylinder bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Symbol Applicable cylinder thread nominal size M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 Symbol 10 16 20 32 40 63 4-070 5-080 8-125 10-
Table of applicable tubings (metric size) FEP, PFA, Modified PTFE, 2-layer soft fluoropolymer, Nylon, Soft nylon, Polyurethane, Hard polyurethane, Soft polyurethane, Polyolefin, Soft polyolefin, Wear Resistant Tubing , Antistatic soft nylon, Antistatic polyurethane 4x2.5, 4x3, 6x4, 8x6, 10x7.5 10x8, 12x9, 12x10, 16x13 1/8"x0.086", 5/32"x0.098", 1/4"x5/32" 5/16"x0.236", 3/8"x1/4", 1/2"x3/8
Series Dimensions ARJ310-01 ARJ310F-01 31 56 56 35 32 22 M12 x 1 Panel cutout dimensions 12.5/Panel thickness: 4 or less 19 2 27 2 x 5.5 57.2 8.5 82.5 15 Applicable tubing O.D.
) 14 (10) 32 (0) 50 (10) 68 (20) 86 (30) Atmospheric pressure dew point F (C) How to read the dew point conversion chart Example) To obtain the atmospheric pressure dew point at a pressure dew point 50F (10C) and a pressure 102 psi (0.7 MPa). 1.
Parameter Definition Item Content Default setting Set the process data size of each port of the IO-Link master. 1 Process Data size 1 to 32 byte 1 Set the I/O size of each IO-Link port. 2 byte / 2 byte direct Data order is not swapped.