Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate l/min (ANR) 1000 680 440 480 420 210 150 INOUT Effective area mm 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note 1) Flow rate values are at a pressure of 0.5MPa and temperature of 20C.
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" 1000 680 440 480 420 210 150 Flow rate l/min ANR (SCFM) INOUT (35.0) (23.8) (15.4) (16.8) (14.7) (7.35) (5.25) Effective area mmCv 15.2 10.4 6.7 7.3 6.4 3.2 2.3 (0.84) (0.58) (0.37) (0.41) (0.36) (0.18) (0.13) Note 1) Flow rate values are at a pressure of 0.5MPa (72 psi) and temperature of 20C (68F).
, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes). b) System input 1280 points/ 160 byte Available This is not settable when the I/O mapping is set to "Auto". size 16, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes).
, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes). b) System input 1280 points/ 160 byte Available This is not settable when the I/O mapping is set to "Auto". size 16, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes).
, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes). b) System input 1280 points/ 160 byte Available This is not settable when the I/O mapping is set to "Auto". size 16, 128 to 1280 points (2, 16 to 160 bytes) Increase and decrease by 128 points (16 bytes).
2B B AMF800 to AMF1000 (Standing style) AMF801/901 (Piping support style) 20 80 AMF 0 20 80 AMF 1 Body size Body size 80 90 80 90 Port size Port size 100 With bracket 20 2BFlange 30 3BFlange 40 4BFlange 20 2BFlange 30 3BFlange 40 4BFlange Shape Piping support style Standing style 60 6BFlange How to Select Max.
Flow Rate and Sonic Conductance AS121F-M3 AS121F-M5 AS131F-M5 AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS131F-M3 Model AS121F-M5-02 2, 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Metric size Tubing O.D. 1/8" , 3/16" 1/8" , 5/32" 1/8" , 5/32" 3/16" , 1/4" , 1/4" , 5/16" , 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled
bytes) Increase and decrease by 16 points. 128 points/ 16 bytes Available b) Input size 0 to 128 points (0 to 16 bytes) Increase and decrease by 16 points. 128 points/ 16 bytes Available c) Output size Slave unit setting The valve output size is included in the output size of each station.
Step designation BIT 5 8 Stp-no. bit4 20 BIT 6 21 Stp-no. bit5 8 BIT 7 9 Stp-no. bit6 21 22 Stp-no. bit7 9 35V DC max. + SET-ON 10 Temporarily stops the program run by means of the ON input. 3 Temporary stop READY HOLD 23 BUSY <2> 11 Performs an emergency stop when ON input stops. 16 Emergency stop (nonlogical input) ALARM STOP 24 COM 12 ALARM RESET 4 Alarm release Releases the alarm being
Use a speed controller to adjust the cylinder drive speed, gradually increasing from a low speed to the desired speed setting. 16 Series CYP Actuator Precautions 2 Be sure to read before handling. Air Supply Mounting Warning Caution 1. Align carefully when connecting to a load having an external guide mechanism.
Then, tighten the mounting screws to fix the valve to the manifold base. 4-7-16
Model HRL100-Am-20 HRL200-Am-20 HRL300-Am-20 CH1 CH2 CH1 CH2 CH1 CH2 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 1.4 2.2 3.0 Control method PID control Ambient temperature [C] 2 to 45 Circulating uid CH1: Tap water/CH2: Tap water, Deionized water1 Set temperature range [C] CH1: 15 to 25/CH2: 20 to 40 Cooling capacity2 [kW] 9 18 19 18 26 18 Heating
Stations Stations Symbol 02 Symbol 02 2 stations 2 stations Double wiring specifications (1) Double wiring specifications Connector mounting position 10 02 11 02 10 stations 11 stations Mounting position Symbol D 2 stations 2 stations Specified layout (2) (Up to 21 solenoids possible) D side Specified layout (Up to 22 solenoids possible) 20 20 20 stations 20 stations PG: Flat ribbon cable
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
Contents Bore size (mm) CQSB12-PS 12 16 20 25 32 40 50 63 CQSB12-PS CQSB16-PS MK20Z-PS MK25Z-PS MK32Z-PS MK2T40-PS MK2T50-PS MK63Z-PS !0 !1 !2 13 !
No.MH*-OMZ0003 / / JMHZ2-16D-X7400B-TM . 2 1. . 4 2. . 5 3. . 6 3-1. . 6 3-2. . 7 3-3. . 8 3-4. . 9 3-5. () . 10 3-6. . 11 3-7. . 12 4. . 13 4-1. . 13 4-2. 3 . 14 4-3. . 15 5. . 16 5-1 . 16 5-2. . 16 5-3.
6Element mounting bracket 16-1 16-2 16-3 472 Series FGB Replacement Procedure of Element 2 4. Method for Removal of Element Assembly 2. Overhaul 2-1. If the differential pressure rises due to clogging and reaches the threshold for element replacement (0.1 MPa), replace the element with the new one. 2-2.
Series SV2000 for EX120 Dedicated Output Serial Wiring. 6 7 8 10 10 10 10 10 10 10 11 11 11 11 11 11 12 12 13 13 13 15 16 16 17 19 20 21 21 23 23 24 24 24 24 24 25 26 27 27 30 30 31 32 33 34 35 36 37 37 39 40 40 41 42 44 45 45 50 50 51 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
25 30 40 50 60 75 100 125 150 175 200 225 250 275 300 Standard Stroke (mm) Bore Size (mm) 6 8 10 12 16 20 25 MXH MXS MXQ MXF MXW MXP Dual Rods For Twice The Force The MXS, MXQ, and MXW use a twin bore design to double the actuation force while maintaining the single bore height.