Model: SGC400, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1 MPa, Thread: Rc, Port Size: 1, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Model: SGC200, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1.6 MPa, Thread: Rc, Port Size: 3/8, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: Conduit Terminal, Surge Suppressor: With Light and Surge Voltage Suppressor, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Model: SGC200, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1 MPa, Thread: NPT, Port Size: 3/8, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal, Surge Suppressor: With Light and Surge Voltage Suppressor, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Model: SGC200, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1.6 MPa, Thread: NPT, Port Size: 1/2, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Model: SGC300, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1.6 MPa, Thread: NPT, Port Size: 3/4, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Model: SGC300, Valve Type: Normally Closed, Seal Material: NBR, Pressure Range: 0 to 1 MPa, Thread: NPT, Port Size: 3/4, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal Without Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: Without Bracket, Auto Switch: M9N--Solid State, Gen.
Model: SGC400, Valve Type: Normally Closed, Seal Material: FKM, Pressure Range: 0 to 1 MPa, Thread: NPT, Port Size: 1, Pilot Valve: 0.35 W Type, V116, Voltage: 110 VAC (115 VAC) 50/60 Hz, Electrical Entry: DIN Terminal, Surge Suppressor: With Light and Surge Voltage Suppressor, Manual Override: -, Bracket Mounting Position: -, Auto Switch: -, Lead Wire: -, Number: -
Series: 10-SY3000, Actuation: 2 Position, Single, Coil Specification: None, Voltage: 3 [110 VAC, (115 VAC)], Electrical Entry: DIN Terminal, w/Connector, Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-Locking Push Type, A, B Port Size: One-touch Fitting for ΓΈ1/4", Thread: -, Bracket: -
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.713/14Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.713/14Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
(50/60 Hz), 240 VAC (50/60 Hz) 12, 24 VDC?
Between case and signal ground: 500 VAC for 1 min.Between case and AC line: 500 VDC, 50 M or more0 to 50C (without freezing)35 to 85% RH (No condensation)Square wave noise from a noise simulator (pulse duration 1 ?s) between power supply terminals ?1500 V, I/O line ?
Stainless steel, Brass, Synthetic rubber, Copper brazing (Heat exchanger)3-phase 200 VAC 50 Hz, 3-phase 200 to 220 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.75/5Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.76/6Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.76/6Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.75/7Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.713/14Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?
0.10.25/0.40 (at 20 l/min)20Approx. 22Approx. 17Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.718/23Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?