Search Results "ISE10-M5-E-R"

Flow Rate Range: 20 to 2000 L/min, Thread Type: Rc, Port Size: 3/4, Output Specifications: PNP; Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: With Bracket, Calibration Certificate: -

Flow Rate Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: PNP; Analog 1 to 5 V, Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: With Bracket, Calibration Certificate: -

Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø6, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch, Lead

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,