SMC Corporation of America
Elite Part Number Search
Search Results "CDS2F140TN-100+25-M9PSDPC4-XC11"

250 200 150 10 100 50 0 1 0 5 10 15 20 25 30 0 5 10 15 20 25 30 Time of water flow (min) Measuring time (min) Test method and conditions The liquid contact portions were filled with sulphuric acid and left untouched for half an hour.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CRA1 CRJ1 CRJ05 Model Even with a single rack design, the use of a special construction minimizes backlash. 30 25 Fr Allowable load (N) CRQ2 25 20 FS (a) MSQ 25 20 FS (b) Pinion gear 6 5 Output shaft size (mm) Stopping the pinion gear by having it strike

Y3 X3 ZY -07L Max. vacuum pressure: 53 kPa Y3 X3 ZY -07S Max. vacuum pressure: 84 kPa Exhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics 50 50 100 100 100 100 Vacuum pressure Suction flow rate (l/min(ANR)) Air consumption flow rate (l/min(ANR)) Suction flow rate (l/min(ANR)) Air consumption flow rate (l/min(ANR)) 40 40 80 80 80 80 Vacuum pressure (kPa

Order separately with part number, AS-T-1. 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard Made to Order (Refer to page 608 for details.) Applicable tubing O.D.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L CZ CT CT Y V U Conveyor lower limit position CD T R Stroke H B 2-P D QA FT A GA Rear pressure port Front pressure port QB 2-Plug WB GB E W (Width across corners I) (mm) Width across corners I 85 103 132 GA 16 24 24 H 128 144.5 171.5 FT 20 25 25 FX

D E FT FX FZ G H I L O P Q R B A Stroke 50 30 225.5 103.5 20 8 35.5 32 64 20 73 93 16 122 85 44 9 1/8 10 36 14 depth 5 63 246 106 20 10 44.5 40 77 25 90 114 24 140 103 53 11 1/4 12.5 43 30 18 depth 6 80 299.5 135 25 10 44.5 50 98 25 110 138 28 164.5 132 54 13 1/4 12.5 49 40 20 depth 6 Bore size (mm) S T U V W WB X Y 24 50 16 3.1 7.2 15.5 72 32 5 10 24.5 63 18.5 3 8.8 16 87.5 38.5 5 10 24.5

Standard Stroke Table Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

6.7 32 7.7 Standard Strokes Standard strokes (mm) 20, 30, 40, 50, 60, 70, 80, 90, 100 Bore sizes (mm) 20, 25, 32 Intermediate strokes are also available upon receipt of order.

kPa to 0.6 100 kPa to 0.6 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0 100 kPa to 0.6 100 kPa to 0.6 N.C.

or less 100 Rubber seal Exhaust center 10-SQ1431 39 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less 100 Rubber seal Pressure center 10-SQ1531 39 or less 0.14 0.20 0.59 0.19 0.21 0.79 25 or less 100 Rubber seal Note 1) Values for the cylinder port size of C6, CYL Values of EXH.

No 3000G 45-089 Stripper for round cable (2.0) can be used for a 2-wire type cable. 181 Applicable auto switch list Cylinder CDQSX CDBM2 CDM2X CDQ2X CDQS CDM2 CDG1 CDQ2 CDA2 CXSJ CDJ2 MGP MXQ Cylinder series MGF MXP MXS CDU REC CXS CYP CUJ 40/63/100 32 to 100 20 to 40 20 to 40 20 to 63 40 to 63 12 to 25 20 to 40 12 to 63 12 to 25 32 to 63 20 to 40 80/100 6 to 10 6 to 25 6 to 32 6 to 16 6

(HRS050-A-20-(BJMTW)) 9.5.2 HRS040-W-20-(BJMTW) 1500 1500 Facility water temperature Facility water temperature 1200 1200 Heating capacity[W] Heating capacity[W] 40 40 900 900 32 32 25 25 600 600 20 20 5 5 300 300 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60H 50H Fig. 9-6 Heating capacity(HRS050-W-20-(BJMTW)) HRS Series

500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 60Hz 50Hz Fig. 9-5 Heating capacity(HRS050-A-20-(BJM)) 9.5.2 HRS050-W-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 5 20 25 32 40 1500 1500 5 20 25 32 40 Heating capacity [W] Heating capacity [W] 1000 1000 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35

50 Lifting force [N] Lifting force [N] 20 40 15 30 10 20 5 10 0 0 0 0.6 0.5 0.4 0.3 0.2 0.1 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure [MPa] Supply pressure [MPa] Air Consumption ZNC30m ZNC40m ZNC20m 160 200 140 180 Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] Air consumption [L/min (ANR)] 140 120 160 120 100 140 100 120 80 100 80 60 80 60 60 40 40 40 20 20 20 0 0 0 0 0.6 0.5

/32 40 50/63 5 Semi-standard/Thread nominal size JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to Order 14-150 JC 40 Thread nominal size (Standard) Applicable

(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel 304 M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel plated

Metal seal 26 or less Ambient and fluid temperature 10 to 50C Note 1) SQ1000 3.2 (0.18) SQ1331 25 or less 100 Rubber seal 33 or less Not required Lubrication 3.2 (0.18) SQ1430 20 or less 100 Metal seal Exhaust center 26 or less Push type/Slotted locking type (tool required) Manual operation Note 2) 4.5 (0.25) SQ1431 25 or less 100 Rubber seal 33 or less 30/150m/s Impact/Vibration resistance

Refer to pages starting with 181 for mounting. 30 95 B 100 95 8(4)-6.2 (160) () () 110 95 20 95 A (140) () () A B Stroke Model LG1H202PA-100-F LG1H202PA-200-F LG1H202PA-300-F LG1H202PA-400-F 100 200 300 400 50 150 250 70 170 270 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)

, 32, 40 Basic Page 2 of this catalog JC Series (Light weight type for light load) Pneumatic cylinder 1 MPa or less 20, 25, 32, 40, 50, 63 Basic JA Series (Standard) Pneumatic cylinder 0.7 MPa or less 6, 10, 15 1 MPa or less 20, 25, 32, 40, 50, 63, 80, 100, 125 140, 160, (180, 200) Basic, Foot, Flange Hydraulic cylinder 3.5 MPa or less 20, 25, 32, 40, 50, 63, 80, 100, 125 140, 160, (180,