Stations: 2 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: None, PR Port: 02D (1/4, Bottom), PR Thread: T (NPTF), Silencer: SB (Silencer Box)

Stations: 8 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: None, PR Port: 03D (3/8, Bottom), PR Thread: T (NPTF)

Stations: 3 Stations, AB Port: 02L (1/4, Left), AB Thread: T (NPTF), Control: None, PR Port: 02B (1/4, Both Sides), PR Thread: T (NPTF)

Area: Japan, Asia, Australia, Stations: 3 Stations, AB Port: 02L (1/4, Left), Control: None, PR Port: 02D (1/4, Bottom), Silencer: None, Voltage: w/o Air Release Valve, Q: Q (CE Approval)

Area: Japan, Asia, Australia, Stations: 2 Stations, AB Port: 02L (1/4, Left), Control: None, PR Port: 03B (3/8, Both Sides), Silencer: None, Voltage: w/o Air Release Valve, Q: Q (CE Approval)

Stations: 10 Stations, AB Port: 02L (1/4, Left), AB Thread: Rc, Control: None, PR Port: 03B (3/8, Both Sides)

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 116 lb

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual,

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 116 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 116 lb

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: None, Option 3: No Operation Manual; No Calibration Certificate, X Options: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual