Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
This is a legacy product, and replaced byISE20B-T-N01-WB-X500, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8 NPT VERSION, .16368 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift
This is a legacy product, and replaced byZSE20B-T-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .27368 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20B-T-P-N01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .47767 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)