SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-R-P-N01"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF 1.3 1.3 ASV220F-U10/32 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1

With One-touch fitting Thread type 1/8 (Male thread), M5 x 0.8 (Female thread) 01 Port size (IN) R, Rc NPT Nil N Accessory Applicable tubing O.D. (OUT) Metric size None Bracket Nil B G ARJ310-01 4 mm 6 mm 04 06 Pressure gauge Note 2) For products with pressure gauge, pressure gauge is shipped together with product. Inch size ARJ310F-N01 5/32" 1/4" 03 07 674

NPT1/8 N02 NPT1/4 F01 G1/8 F02 G1/4 C4 4(5/32") C6 6 C8 8(5/16") N7 1/4 -10No.PF-OMJ0005CN-I 1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

ASP-X369 Series Compact With One-touch Fitting Wide size variations VQ1000 (2000)-FPGDouble check block DIN rail mountable With One-touch Fitting Best Pneumatics (1) VQ1000-FPG Refer to P.1053. VQ2000-FPG Refer to P.1059.

DIN Rail Mounting Bracket (Order Separately) ZS 33 R Stations 1 2 3 4 5 1 station 2 stations 3 stations 4 stations 5 stations DIN rail (supplied by customers) Port size F02: G1/4 cannot be mounted on the DIN rail. 907

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)