F G J Power supply cable Nil Z N With power supply cable (3 m) With power supply cable (10 m) Without power supply cable K Output specification NPN output PNP output Nil P Control unit cable entry direction Nil R Left-hand entry Right-hand entry 666 A Series IZS31 Made to Order 4 Please contact SMC for detailed dimensions, specifications, and lead times.
L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP + Analogue output type PF3A7##H-L3/L4#-##-# Maximum load current: 80 mA Internal voltage drop 1.5 V max.
Internal voltage drop K Key-lock function A function that locks the set buttons so that no accidental setting changes can be made. -14No.PF-OMY0002 Terminology Definition M The resolution of set and display values. If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12.
L3: Analogue output: 1 to 5 V or 0 to 10 V Output impedance: 1 k L4: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 PNP + Analogue output type PF3A7##H-##-L3/L4#-## Maximum load current: 80 mA Internal voltage drop 1.5 V max.
K Button operation See fig. 43-5 for details Being adjusted Q Balance current Hunching Hunching Operation failed readjustment occurred occurred Set button 1s K Button operation See fig. 43-5 Being adjusted for details R Balance current Hunching Hunching Operation failed readjustment occurred occurred Normal end Set button 1s K Hunting converged Fig. 45-4 No.IP8S-OM09 68 Balance current readjustment
Series SJ2000 SJ3000 Back pressure check valve Single wiring Double wiring Nil D 2 3 Nil K None Built-in There is no need to enter anything for 2 position double, 3 position and 4 position solenoid valves. Select this when the unused numbers to wiring are set. Refer to page 3 for details.
Rated voltage Pressure specification Nil K Standard (0.7 MPa) DC High-pressure type (1.0 MPa) 5 6 24 VDC 12 VDC Coil specification AC (50/60 Hz) Nil T Standard 1 2 3 4 7 B 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] 240 VAC 24 VAC With power saving circuit (DC only) T type is only available for DC mode.
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System Solenoid valve Speed controller Tubing diameter x Length Silencer A B C D E F G H I J K 10 x 1 m 12 x 1 m 12 x 1 m SGP15A x 1 m SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m VEX VEX3 2-02 1 2 AS4000-02 AN200-02 AS420-03 AS420-04 AS420-04 AS500-06
Series SJ2000 SJ3000 Back pressure check valve Single wiring Double wiring Nil D 2 3 Nil K None Built-in There is no need to enter anything for 2 position double, 3 position and 4 position solenoid valves. Select this when the unused numbers to wiring are set. Refer to page 3 for details.
B 2 (EA)5 1 (P) 3(EB) M5: M5 x 0.8 3 position closed center 2(B) (A)4 Back pressure check valve 3 J: With switch A 4 Nil None (EA)5 1 (P) 3(EB) K Built-in 2 B 3 position exhaust center The built-in back pressure check valve type has an effective area approximately 20% smaller.
f. g. h. i.() j. k. l. m. n. (IDF )(AF/AFF )(AFM/AM , -9- 4 4 4 4-2. 2. 2. 2. 4-2-1. D D 4-2-2.
An excessive amount of the circulating fluid is observed in the tank. 07 Reservoir High Level WRN Continued Drain the circulating fluid. Check the load specification. Replacement of the thermal fuse is required. Call the supplier for service. 08 Temp. Fuse Cutout FLT Stop The circulating fluid tank was raised in temperature.
Nominal filtration rating: 30 m 0 to 101 kPa 100 to 100 kPa 849 Compact Vacuum Ejector Series ZA How to Order Ejector Unit ZA1 1 07 K1 P1 5 L 0 1 Nozzle nominal size Vacuum (V) port 05 07 0.5 0.7 Symbol 1 2 4 5 Applicable tubing O.D. Part no. KJS23-M5 KJS04-M5 KJL23-M5 KJL04-M5 3.2 (Straight) 4 (Straight) 3.2 (Elbow) 4 (Elbow) Solenoid valve combination (Refer to Table (1).)
IC Electroless nickel plated Dimensions VBA Caution A Model ARJ1020F-M5-04 B 10.4 C 4 D E F G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
(Example) VV5Z3-43P-07-C41 pc. (Manifold base) VZ3143-5MOZ 3 pcs. (Valve) VZ3243-5MOZ 3 pcs. (Valve) DXT192-13-3A1 pc. (Blanking plate assembly) DXT192-52-1-4A3 pcs. (Connector assembly) DXT192-52-2-4A3 pcs. (Connector assembly) The asterisk denotes the symbol for assembly.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
How to Order ARM11A 3 1 A M Z 07 q w e r t y u i N 1. Knob Position 2. IN/OUT Piping Position OUT side fitting Elbow IN side OUT side Symbol Position Front Top Bottom IN side fitting Elbow Position Symbol Bottom Top Bottom Top Top A B C Top Front Bottom 1 2 3 4 Top OUT side fitting Straight IN side fitting Straight Bottom Bottom 3. Regulator Block Stations 4.
Series KV2 How to Order KV2 L 07 35 S Series Sealant Body Style With Sealant (as applicable) S Male Connector Straight Union Cartridge Straight H Thread Size 1/16 NPT 33 Male 45 Elbow Cartridge 45 Elbow K 1/8 NPT 34 Male 90 Elbow Plug-In 90 Elbow Union 90 Elbow Cartridge 90 Elbow 1/4 NPT 35 L 3/8 NPT 36 1/2 NPT 37 3/4 NPT 38 Male Branch Tee Union Tee T Union 00 Male Branch Y Union Y Plug-In