Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Warning 1. Do not use in environments where there is a danger of corrosion.
Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Keep the instruction manual where it can be referred to as needed. Warning 1.
Specifications Grade 1 Note 1) Particulate generation grade Air Fluid Series KPQ Brass (electroless nickel plated) Release button: Light gray 1MPa (145 psi) Note 2) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure 3MPa (435 psi) Proof pressure 20C (68F) 5C to 60C (23F to 140F) Ambient and fluid temperature JIS B0203 (taper threads for piping) Threads Note 1) Refer
Specifications Particulate generation grade Grade 1 Note 1) Fluid Air Series KPQ Brass (electroless nickel plated) Release button: Light gray Maximum operating pressure (20C) 1MPa Note 2) Operating vacuum pressure 100kPa Proof pressure (20C) 3MPa 5C to 60C Ambient and fluid temperature Threads JIS B0203 (taper threads for piping) Note 1) Refer to particulate generation grade classifications
Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Keep the instruction manual where it can be referred to as needed. Warning 1.
Use in low temperature environments The valve can be used at a temperature down to 5C. Take appropriate measures to avoid freezing of drainage, moisture, etc. 2. Operation method The valve must be switched to each position instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction.
Use in low temperature environments The valve can be used at a temperature down to 5C. Take appropriate measures to avoid freezing of drainage, moisture, etc. 2. Operation method The valve must be switched to each position instantly and securely. Stopping the handle halfway between the extreme positions may cause malfunction. VHS 5-8-15
MXP6 MXP8, 10, 12, 16 L2 L2 Shock absorber model RB0805 RB0805 RB0806 Applicable size MXP10 MXP12 MXP16 L2 Table 2 L2 (mm) 10 (one side only) 10 (one side only) 9 8 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP8-10C MXP8-20C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Stroke Adjustment Urethane bumper Lock nut Lock nut MXP6 MXP8, 10, 12, 16 Shock Absorber Loosen the lock nut, adjust
Note 3) Temperature conditions: at 20C (5C), in other cases, 6C F.S.
Use the product within the range of specifications for fluid and ambient temperature Take measures to prevent freezing when used at 5C or less, since moisture in circuits can freeze, causing malfunction. 2. Install air filters Install air filters near valves on their upstream side. The filtration degree should be 5 micron or less.
Take measures to prevent freezing at temperature below 5C, since moisture in circuits may freeze and cause damage to seals and lead to malfunctions. 5. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. Cushion Caution 1.
Buffer stroke 25 50 75 100 40 50 63 80 100 125 Series ZPT ZPX Pad Material and Characteristics : Little or no influence : Can be used depending on conditions X: Not suitable Characteristics Operating temperature range (C) Oil resistance gasoline Oil resistance benzol Solvent resistance (Benzene, toluene) Durometer HS (5C) Base resistance Acid resistance Abrasion resistance Ozone resistance
Take measures to prevent freezing at temperature below 5C, since moisture in circuits may freeze and cause damage to seals and lead to malfunctions. 5. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. Cushion Caution 1.
Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Best Pneumatics vol.4 catalog for further details on compressed air quality. Piping Caution 1.
If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals and equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to Best Pneumatics No. 5. Lubrication Caution 1. The non-lube type air gripper is lubricated at the factory, and can be used without any further lubrication.
Mandrel Here, : Deformation ration (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Handling of One-touch Fittings Test temperature: 20 5C Relative humidity: 65 5%. Caution 3. Applicable for general industry water. Please consult with SMC if using other fluids.
Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing moisture in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.