RS(D)Q32/40/50LZ How to Order Lever type RS(D)Q32/40/50BZ RS(D)Q32/40/50CZ RS(D)Q32/40/50DZ RS(D)Q32/40/50EZ Mounting base Table 1. Recommended hole diameter Recommended hole Rod cover boss diameter of the mounting base O.D. Model T D RS(D)Q32 36 38 RS(D)Q40 44 48 RS(D)Q50 56 57 Fig. 3 6 - 7-3.
E PE Item Spec. 500 500 Facility water temp. 35deg.C RS-232C RS-485 Model No.
Modes Setting contents Setting range Default SEL Operation + Ensure that external instruments connecting to this product provide the Level 2: Used at maintenance and initial setting 1 Serial communications RS-232C / RS-485 RS-232C, RS-485 RS-232C enclosure complied with UL61010-1 and use the cable which provide flame resistance (over VW-1). for setting of controller/PID. + SEL Operation
RSQ RSG RS MI Working principle Working principle Extension of Finger A rotates the cam to unlock Finger B and lock finger A to allow retraction of Finger B. The cam locks Finger B. When Finger A is extended to reach the stroke end, air is supplied to retract Finger B.
D Lever type models Caution RS (D) 32/40/50-L RS (D) 32/40/50-B RS (D) 32/40/50-C RS (D) 32/40/50-D RS (D) 32/40/50-E Mounting base 1. Do not allow a pallet to collide with the cylinder when the lever is upright.
5: SD+ Circuit diagram 5 6: SD 9 7: SG * The terminal resistance of RS-485 (120 W) can be switched by the operation display panel.
-485 Table 8-5 Serial RS-485 Item Specification Connector No.
Free mounting Examp e:Au1o swfch & speed conlro er mountinq Extemal shock absorber types 4 tO 10 tinus more allowable kinetic energy Rotation Longludna f.oLr.ling space rs reduced bealse lhere rs no pralruson irom adjushenl bots or nterna shock absorbrs shock abcotbers a avaiaHe, lbr low energy and high energy E g P n E E ooor jad .(8)t, o-7., 0 2 0 3 0 4 0 5 0 6 0 7 0 3 0 9 1 0 RoE!
Serial Communication The serial communication (RS-485/RS-232C) enables the following items to be written and read out. For details, refer to the Operation Manual for communication.
Serial Communication The serial communication (RS-485/RS-232C) enables the following items to be written and read out. For details, refer to the Operation Manual for communication.
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT CONTACT OFFICE 1.195 LINEAR ACTUATOR: STOPPER CYLINDER SERIES RSQ D I M E N S I O N S R O L L E R T Y P E RS(D)QB20 D I M E N S I O N S R O L L E R T Y P E RS(D)QB324050 Bore A B C D E F H I J K M N 0 counter bore O Thread P Q S T U V W Z G L X 32 87 48 15 20 45 7.5 39 60 4.5 32 34 5.5 9 depth 7 M6X1 1/8 20 18 36 31.5
B 17.5 SUP/EXH block Stations 1 2 3 4 5 4 Description/Model SSQ2000-PR-3-C10Single Option Nil Standard External pilot specifications Built-in silencer Valve Option Port size C8 C10 N9 N11 One-touch fittings for 8 One-touch fittings for 10 One-touch fittings for 5/16" One-touch fittings for 3/8" R S SUP/EXH block SSQ2000-PR-3-C10Note) When specifying both options, indicate RS.
www.stevenengineering.com I 1.195 LINEAR ACTUATOR: STOPPER CYLINDER SERIES RSQ D I M E N S I O N S R O L L E R T Y P E RS(D)QB20 D I M E N S I O N S R O L L E R T Y P E RS(D)QB324050 Bore A B C D E F H I J K M N 0 counter bore O Thread P Q S T U V W Z G L X 32 87 48 15 20 45 7.5 39 60 4.5 32 34 5.5 9 depth 7 M6X1 1/8 20 18 36 31.5 20 58.5 8 3 8 18 40 105.5 52.5 18 25 52 8 53 69 5 41 40 5.5
Note) Enter "-RS" for both options.
A, B port size Thread piping SUP/EXH block assembly specifications Symbol Nil R S RS Symbol Port size Specifications 1 4 02 03 3 8 Standard/Internal pilot specification External pilot specification Internal pilot/Built-in silencer External pilot/Built-in silencer The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Number of connectable drivers Remote register input Available with CC-Link communication (2 stations occupied) Available with CC-Link communication, RS-422 communication CC-Link communication (1 station occupied): 31 points CC-Link communication (2 stations occupied): 255 points RS-422 communication: 255 points Command method Point table No. input Available with CC-Link communication CC-Link
RS Q G ND hole H10 RS H A Rod dg RZQ +0.2 0 NX MI W S CEP1 Material: Rolled steel Material: Brass Material: Iron CE1 Applicable bore size A1 L1 L MM Part no. Y-J010B Applicable bore size Applicable bore size B C d H B C d H Part no.
Compatible Driver -@ type -# type Driver type Series LECYM LECYU Applicable network MECHATROLINK2 MECHATROLINK-3 Control encoder Absolute 20-bit encoder Communication device USB communication, RS-422 communication Power supply voltage [V] 200 to 230 VAC (50/60 Hz) Reference page Page 766 672 Electric Actuator/Slider Type Ball Screw Drive LEFS Series AC Servo Motor Specifications AC Servo
Compatible Drivers -@ type -# type Driver type Series LECYM LECYU Applicable network MECHATROLINK2 MECHATROLINK-3 Control encoder Absolute 20-bit encoder Communication device USB communication, RS-422 communication Power supply voltage (V) 200 to 230 VAC (50/60 Hz) Reference page Page 103 56 Series LEJB Specications LEJB40/63 AC Servo Motor Model LEJB40V6 LEJB63V7 Stroke [mm] Note 1) 200,
(N.O. type/N.C. type can be changed.) 3 Do not connect wiring. 1 14 25 13 D-sub 25-pin female (socket) type 8 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Communication Functions Serial Communication The following operations can be performed by the serial communication RS-232C/RS-485.