Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Passage: 41 (Common SUP, Common EXH, Side Ported), Stations: 11 Stations, Port Size: M5 (M5X0.8)
Gun Type Ionizer IZG10 Series IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment *1 Lightweight 200 g Only *1 Body weight Lighting LED Reduced operating force Easy to hold grip Blow setting function p. 179 Select from continuous blow or pulse blow.
8mm Tube 10 10mm Tube 01 Rc 18 02 Rc 14 Operating Temperature Range 5 ~ 60C / 40~140F N Canada, USA Other (PT) Lubrication Forbidden N O Z Z L E D I A M E T E R V A C U U M P O R T 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm 06 6mm Tube 08 8mm Tube 01 Rc 18 02 Rc 14 07 1/4 Tube 11 3/8 Tube T01 1/8NPT T02 1/4NPT S Y M B O L S T Y P E I N L E T P O R T B Box type D Body type 06 6mm Tube 08 8mm Tube
NT-04 NT-05 NT-08 NT-10 21 25.4 22 8 M14 x 1.5 CX 26 31.2 27 11 M18 x 1.5 31 37.0 32 13 M22 x 1.5 CY 39 47.3 41 16 M26 x 1.5 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Allowable Kinetic Energy RHC Operate the stroke reading cylinder with brake within the
Model (L) 3 E J M H W ( T ) L N LQ1F41 LQ1F42 LQ1F51 LQ1F52 LQ1F61 LQ1F62 12 10 19 12 25 19 60 53 34 SMC 30 12 33.1 28 21 65.2 58 (M) W N J SMC 58 41 36 14 40 32 26 3/4 19 63.2 (E) (T) H 69 51 81.5 36 14 49 39.5 Class 4, 5 JIS 10K flange Inch sizes H Applicable tubing O.D.
Model N L L E J M H W ( T ) 3 TI/ TIL 12 10 19 12 25 19 LQ1F41 LQ1F42 LQ1F51 LQ1F52 LQ1F61 LQ1F62 60 53 34 28 33.1 12 30 21 PA 65.2 58 SMC (W) (M) N J SMC 58 41 40 14 32 36 26 PAX 63.2 3/4 19 69 51 81.5 49 14 39.5 36 H (E) (T) PB JIS 10K flange Class 4, 5 Inch sizes Applicable tubing O.D.
oO OUT 12,17 304 609 913 1217 1522 1765 30 IN 11 .08 277 554 831 1108 1385 1606 Note) Theoretical outpul(lbl) :: Pressure (pSI) X Piston area (IrI(:h2) Bore SlZ9 .
of 01 to 08 when the suffix 0 is removed, are the same as the solenoid valve model codes.
N L1 L2 L3 L4 L5 L6 P Q1 Q2 M KRM12-06-02-10 KRM12-06-02-6 99 10 6 6 89 47 1 4 17 19.5 33.5 23.5 33 13.5 8.5 13 19 10 125 6 108 10 55 73 106 104 KRM12-08-03-10 KRM12-08-03-6 3 8 8 19 139 11.5 22.5 37.5 26 36.5 10 15.5 20.5 14.7 86 126 119
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
22 27 32 41 41 19.6 25.4 31.2 37.0 47.3 47.3 16.5 21 26 31 39 39 79.5 69.5 Note 1) When using cotter pin, flat washer is used together.
RoHS Ionizer Series IZS40/41/42 How to Order Type 40 Standard type IZS 40 IZS 42 1600 1600 10 10 B B Type 40 Type 41/42 Made to Order Bar type Type 41 42 Feedback sensor type Dual AC type IZS41 IZS42 Sensor Symbol Sensor Built-in sensor Feedback sensor Auto balance sensor [High accuracy type] Nil F G Electrode cartridge type/Electrode needle material Feedback sensor cannot be used for the
JIS symbol Auto switch model D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 25 to 1000 25 to 1000 25 to 1300 25 to 1500
SO-63 27 28 60 M' 8Xl .5 15 27 12'870 1 6 ~f 38 ~10 100 105 37 40 83 M26Xl .S 24.5 28 20-8-08< 3():gJ Y-08d 80 37 36 71 M22Xl .S 19 28 181. 010 28!lH 55 V-1Od 100 37 40 83 M26Xl .S 21 38 201re
06 FH440-08 FH440-10 FH440-12 FH640-03 FH640-04 FH640-06 FH640-08 FH640-10 FH640-12 3/8 3/8 10 10 FH441-04 FH441-06 FH441-08 FH441-10 FH441-12 FH441-16 FH441-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40
-06-08-01S-3 33 80 83 84 17 20 15.5 12.8 45.4 17 11.1 18.5 76.5 77 78 41 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 44 45 67 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 10 8 KM14-08-10-02S-3 48 88 89 90.5 94 95 98.5 19 71 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19
Note 1) l (Drill through) Cotter pin d D m Dd9 L H B C 3 x 18l 4 x 25l 4 x 35l M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 16.5 21 26 31 39 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 36 51 72 4 4.5 5 3 4 4 44 60 82 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 -0.040 -0.076 -0.050 -0.093 -0.065 -0.117 Note 1) A cotter
Locked Manual lock released Refer to page 41 for the manual lock release.
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5