Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)

ZH VACUUM EJECTOR, ModelConnection (One-touch/Screw-in) SUPVACEXHZH07D?6/Rc 1 8?6/Rc 1 8?6/Rc 1 8

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M

Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: F01 (G1/8), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket for w/o Flow

This is a legacy product, and replaced byAR20K-F01-B, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, CA, AR MASS PRO 1/8 MODULAR (PT), .62480 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator with Backflow Function Series AR KPages 346 through to 355AR20K1/8, 1/4BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge

The gasket part number for the VS7-6 and the VP7-6 is "AXT500-13," and the gasket part number for the VS7-8 and the VP7-8 is "AXT510-13." The VQ7-6 gasket part number is "VQ7060-13-4-1" and the VQ7-8 gasket part number is "VQ7080-13-4-1."

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-90 kPa), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-90 kPa), SUP: 11 (One-touch Fitting ø3/8"), VAC: 13 (One-touch Fitting ø1/2"), EXH: 13 (One-touch Fitting ø1/2")

Nozzle Diameter: ø2.0mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø3/8", VAC: One-touch Fitting ø1/2", EXH: One-touch Fitting ø1/2", Accessories: -