SMC Corporation of America
Elite Part Number Search
Search Results "VFN212N-3D-02"

K M :, N P 5 H ZZ f h , ZZ, : '*' Refer to 'Minim um Stroke for Auto SWitch Moontlng ' on page 22 (m'Pt .. " 125 17 I 15 27 13 M30 x 1.5 3D. 5 1/2 98 110 221 75 40 133 1~ stroke 244 t-W 17 I 15 27 13 M30 x 1.5 30 .5 112 98 110 221 75 40 133 l,i; stroke 244 160 20 I 17 34 15 M36 x 1.5 34 .5 314 106 120 241 75 40 141 1h; stroke 262 ~ The minimum stroke w ith rod 0001 IS 30 mm or more.

DIN terminal (With surge voltage suppressor) VXD XL Lead wire length XL1 XL2 XL3 XL4 600 mm 1000 mm 1500 mm 3000 mm Conduit terminal (With surge voltage suppressor) 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC DIN terminal (With surge voltage suppressor) Enter symbols in the order below when ordering a combination of electrical

Manufacturer Connector size Number of pins Applicable series example M8-3D 3 Corrence Corporation M8 M8-4D XS3 OMROM Corporation VA-4D Corrence Corporation XS2 OMROM Corporation 4 M12 PA5-4I Yamatake-Honeywell Co., Ltd. HR24 Hirose Electric Co., Ltd.

Fitting Type: L (Elbow), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT)

Fitting Type: L (Elbow), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT)

Fitting Type: R (Run Tee), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT)

Fitting Type: L (Elbow), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: F (Female), Thread: N (NPT)

Fitting Type: B (Branch Tee), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT)

Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)

Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 3D (Tube O.D. 3/8", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male), Thread: N (NPT), Packaging: 1 (Standard Packaging Equivalent to Class

A 3D-CAD drawing will be generated according to the selected position on the displayed value range. For example, select the min. value to see the gripper with the fingers in a fully closed state, and select the max. value to see it with the fingers in a fully open state.

Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: D (Double Solenoid)

Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: D (DIN Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: D (Double Solenoid)

Voltage: 1 (100 VAC, 50/60 Hz), Electrical Entry: E (Grommet Terminal), Light/Surge Voltage Suppressor: None, Manual Override: A (Non-Locking Push Type, Extended), Thread: Rc (PT), Solenoid: Single Solenoid, CE Marking: Q (CE Marked Product)

Voltage: 5 (24 VDC), Electrical Entry: G (Grommet), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: Single Solenoid, CE Marking: Q (CE Marked Product)

Voltage: 24 VDC, Electrical Entry: DIN Terminal, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: Double Solenoid, CE Marking: -

Voltage: 110 to 120 VAC, 50/60 Hz, Electrical Entry: DIN Terminal, Light/Surge Voltage Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: Double Solenoid, CE Marking: -

Voltage: 100 VAC, 50/60 Hz, Electrical Entry: Grommet Terminal, Light/Surge Voltage Suppressor: None, Manual Override: Non-Locking Push Type, Extended, Thread: Rc (PT), Solenoid: Single Solenoid, CE Marking: CE Marked Product

Voltage: 24 VDC, Electrical Entry: Grommet, Light/Surge Voltage Suppressor: w/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flush, Thread: Rc (PT), Solenoid: Single Solenoid, CE Marking: CE Marked Product