-X425 Proof pressure (MPa) 3.0 Maximum operating pressure (MPa) 2.0 Set pressure range (MPa) 0.1 to 1.6 Ambient and fluid temperature (C) 5 to 60C (with no freezing) Applicable Model Model AW20 AW40 AW40-06 AW60 1/8, 1/4 AW30 AW30-03-2-X425 Port size 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 30 AW X425 2 03 BG Option/Semi-standard: Select one each for a to f.
/O.D. mm 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 167 Series KK Flow Characteristics Air (0 to 1 MPa) Water (0 to 0.4 MPa) KK2 KK2 0.007 0.50 Series KK2 (KK2S-M5M + KK2P-M5M) Series KK2 (KK2S-M5M + KK2P-M5M) 0.45 0.006 0.40 0.005 0.35 Flow rate m3/min (ANR) Flow rate m3/min Flow rate m3/min 0.30 0.004 0.25 0.003 0.20
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2007 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing KY printing LX 13500DN Printed in Japan.
Air consumption (per unit) 0.058 m3/min (ANR) 0.085 m3/min (ANR) J (= Unit of conversion of A) Air consumption (for total operation) 6,525 m3/year 95,625 m3/year K = J x 60 x I Power consumption 2 0.19 kW 0.27 kW L (Theoretical value obtained from A and B) Power consumption cost per year 5,344 yen/year 75,938 yen/year M = C x I x L 1 Adsorption time is the time in a cycle when the ejector
(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.
(mm) 9 50 18 6.5 10 YB-03 32, 40 80 UA C d1 d2 H K L UT Weight (g) Part no.
Applicable mounting bracket Bore size (mm) Joint 55 6 18 56 YA-03 32, 40 A type mounting bracket B type mounting bracket 100 8 22 67 YA-05 50 YA-03 YB-03 32, 40 YU-03 YA-05 YB-05 50 YU-05 B type mounting bracket Allowable eccentricity mm Bore size 32 40 50 1 Eccentricity tolerance 0.5 Backlash
Specifications 0.01 m (95% filtered particle diameter) Filtration of outlet air Max. 0.1 mg/m3 (ANR) (0.08 ppm) Note) Outlet air oil mist concentration (Prior to oil saturated 0.01 mg/m3 (ANR) or less, (0.008 ppm or less)) Note) With inlet air oil mist concentration of 30 mg/m3 (ANR) (24 ppm) Applicable Model Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46
max (from 3 of graph MY2H/M3) = 60 (Nm) MX M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 MTS Load factor 3 = M3/M3 max = 10.33/60 = 0.17 MY 5.
YA 03 YA-03 YA-05 18 20 6.8 9 16 20 6 8 42 50 6.5 6.5 10 12 Applicable air cylinder bore Bore size (mm) 32, 40 50, 63 03 05 32, 40 50, 63 U V W Mass (g) Part No.
YA-03 Joint . YU-03 T1 B 2-D through 2-O counterbore (mm) Bore size (mm) B D E J M O Part No. 12 7 25 9 34 11.5 depth 7.5 YB-03 32, 40 12 9 32 11 42 14.5 depth 8.5 YB-05 50, 63 Joint Weight (g) Bore size (mm) T1 RS T2 V W Part No.
Q1 M3 5.5 to 8 Y-1 10 15 X-3 7.5 to 14 M3 Y = M3, M4 7.5 to 9 Y-1.5 L2 = L1(3 x P) C2 = C 15 20 X-4 M3, M4 10 to 18 9 to 10 Y-1.5 M3, M4, M5 X = 20 30 12 to 20 X-4.5 M3, M4, M5 11 to 13 Y-2 M3, M4, M5, M6 L1 = Q2 = M 30 40 14 to 22 X-5 14 to 15 Y-4.5 M3, M4, M5, M6 M3, M4, M5, M6, M8 24 Simple Specials Series CRB2 Axial: Top (Long-shaft side) Axial: Bottom (Short-shaft side) Symbol: A10 Symbol
Operating pressure at the outlet: 0.5 MPa Air consumption of one line at end: 1.2 m3/min (ANR) Air consumption time: 20% of annual operating time of 2500 hours Compressor efficiency: 0.7 Electric power cost: 15 yen/kWh Compressor capacity: 8 m3/kWh S coupler S coupler 0.5 MPa 1.2 m3/min (ANR) Features 1 Series KK130 Variations Plug (P) Socket (S) Male thread type Male thread type Model Port
AR2501-03 AR2501-03 0 I !
CUJB10-4 -6 -8 -10 -15 -20 M2.5 x 21L M2.5 x 23L M2.5 x 25L M2.5 x 27L M3 x 22L M3 x 24L M3 x 26L M3 x 28L M3 x 33L M3 x 22L M3 x 24L M3 x 26L M3 x 28L M3 x 33L M3 x 38L M3 x 22L M3 x 24L M3 x 26L M3 x 28L M3 x 33L M3 x 38L 4 4 14 M2.5 x 14L 5 5 18 M3 x 18L 5 5 18 M3 x 18L 5 5 18 M3 x 18L For axial mounting With Auto Switch For side mounting A B 27 29 31 33 38 27 29 31 33 38 43 27 29 31 33
(Example) For M3: L1 = 6 mm (Example) For M3: L2 = 6 mm $Applicable shaft type: W $ Applicable shaft type: W L1 + (3 x P) Q1= M (mm) L1 = Y Q2 Size (mm) Y = 15 X Q1 1.5 to 9 M3 Size 20 15 L2 + (3 x P) 1.5 to 10 M3, M4 4 to 18 M3 30 20 2 to 13 M3, M4, M5 X = 4.5 to 20 M3, M4 L2 = 40 30 4.5 to 15 M3, M4, M5 Q2 = M 5 to 22 M3, M4, M5 Symbol: A3 The long shaft can be further shortened by machining
x 10-3 = 2.81 (Nm) Load factor 2 = M2/M2 max = 2.81/50 = 0.06 m3 M2 9 Model Selection Series MY2 Calculation of Guide Load Factors X M3: Moment M3 max (from 3 of graph MY2H/M3) = 60 (Nm) M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 Load factor 3 = M3/M3 max = 10.33/60 = 0.17 5 Calculation of load factor for dynamic moment Z Equivalent load FE at impact 1.4 100 1.4 100
X-axis Y-axis Z-axis X Z W 10 mm 10 mm 40 mm 2 kg 10 Y Y 3 Calculation of Load Factor for Static Load m3: Weight m3 max (from q of graph MY3M m3) = 5.33 (kg) m3 Load factor 1 = m3 / m3 max = 2 5.33 = 0.38 Z M2: Moment M2 max (from w of graph MY3M M2) = 6 (Nm) M2 = m3 x g x Z = 2 x 9.8 x 40 x 10-3 = 0.78 (Nm) m3 Load factor 2 = M2 M2 max = 0.78 6 = 0.13 M2 M3: Moment X M3 max (from e