SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-46-06-M5T"

(mm) a b Note 2) Effective area (mm2) Note 1) D Weight (g) M2 M1 L Model Applicable tube a 3.2 4 6 8 10 12 4 6 8 10 12 16 KQG2H23-04 KQG2H04-06 KQG2H06-08 KQG2H08-10 KQG2H10-12 KQG2H12-16 3.4 5.6 13.1 26.1 41.5 58.3 12.6 13.6 16.1 17 18.6 20.8 6.5 11.6 16.3 26 33.3 54.7 12 12.6 13.6 16.1 17 18.6 9 12 14 17 19 24.6 25.6 27.2 30.7 34.1 36.6 40.4 D M2 M1 L Note 1) D is maximum diameter.

ON OFF Output Maintenance signal Requirement for maintenance detected ON OFF Input External switch signal 1, 2 16 IZN10E Series Dimensions Energy saving static neutralization nozzle IZN10E-01m 06 07 High flow rate nozzle IZN10E-02m 06 07 18.31 (100) 2.5 16 5 92.5 46 3.5 L 6 18.5 6 11 8 L 12.4 5 6 M3 x 0.5 thread depth 4 (Ground terminal) 40 27.7 L-L Applicable tubing O.D. d A 86.4 [mm] Model

Auto switch models Bore size (mm) 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F5BA/F59F/F5NT D-A5/A6/A59W D-Z7/Z80 BS5-125 BMB5-032 BA7-040 BA7-040 BA7-063 CHQ CHK BT-12 BT-03 BT-04 BT-04 BT-06 CHN BS4-125 BMB4-032 BA4-040 BA4-040 BA4-063 Note 1) D-A5/A6/A59W cannot be mounted to 40, 50.

6.5 8 53 2.3 31.3 38.5 19 7 157 123.9 122.2 117.8 122.3 137.8 142.3 AW40-D 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 186.9 155.6 153.9 149.5 154 169.5 174 AW40-06-D 50 54 55.5 8.5 10.5 70 2.3 35.5 42.5 21 7 188.9 157.6 155.9 151.5 156 171.5 176 AW60-D 70 75 66 11 22 113 3.2 273.9 242.6 240.9 236.5 241 256.5 261 The dimension C is the length when the filter regulator knob is unlocked. -46-

22 2.2 24 2.3 25 2.4 25 2.5 26 3 CC-Link 313-61 3.1 32 3.2 33 3.2.1 33 3.2.2 34 3.2.3 37 3.2.4 38 3.2.5 38 3.3 39 3.3.1 39 3.3.2 39 3.4 3-10 3.5 CPU( 3-10 3.5.1 3-10 3.5.2 3-14 3.5.3 3-23 3.5.4 (RWwn2RWwn3) 3-24 3.5.5 (RWrn2) 3-32 3.5.6 CN6 3-33 3.6 3-35 3.6.1 3-35 3.6.2 3-37 3.6.3 3-39 1 - 3.7 3-42 3.7.1 3-42 3.7.2 3-45 3.7.3 3-46

3/8" 25 22.5 21 19.5 44.5 32.5 47.5 1/2" 52.5 33 29 24.5 54.5 24 22.5 3/4" 61.5 40 37 26.5 64 32 24 1" 73 46 49 30 77 41 26 328 Series LQ3 Fluoropolymer Fittings Hyper Fitting / Flare Type Dimensions Female elbow: LQ3L-F Metric Size Y Port size Rc (NPT) B Applicable tubing O.D.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.

Blanking plug (For one-touch fittings) L KJP-02 Dimensions 23 04 06 KQ2P(mm) A Applicable fitting size d 2 3.2 4 6 A L D Model Weight: g KJP-02 KQ2P-23 KQ2P-04 KQ2P-06 8.2 16 16 18 17 31.5 32 35 3 3.2 6 8 0.1 1 1 1 It is inserted into an unused cylinder port and SUP/EXH ports.

Modular Type Lubricators Series AL AC-A Lubricator Series AL Model AF-A Port size Option AF-A AL10 M5 x 0.8 AR-A AL20 1/8, 1/4 AL-A AL30 1/4, 3/8 AW-A AL40 1/4, 3/8, 1/2 Bracket AC AL40-06 3/4 AF AL50 3/4, 1 AF AL60 1 Pages 508 through to 513 AR AL AL AW AG E AV AF 507 Lubricator AL10 to AL60 Symbol Lubricator AL20 AL40 How to Order AL 30 03 B Option/Semi-standard: Select one each for a

Besides, when the arrangement will be complicated, specify them by means of the manifold specification sheet. 11 Series VQC2000 Plug-in Unit Base Mounted Manifold Options Refer to pages 44 through to 46 for details.

The parameter No.PC07 (home position return position data) setting value is the positioning address after the home position return is completed. 5 46 5.

The parameter No.PC07 (home position return position data) setting value is the positioning address after the home position return is completed. 5 46 5.

(mm) Note) Weight (g) M2 D Applicable tubing Applicable tubing a b a b KGH04-06 34.5 6 4 6 8 10 17 18.5 21 22 Note) D: Max. diameter 12.8 16 5.6 4 5 8 KGH06-08 38.5 15.2 17 13.1 10.4 6 10 KGH08-10 42 18.5 18.5 26.1 18.0 11 12 KGH10-12 44.5 20.9 21 41.5 29.5 14 Male Elbow: KGL H (width across flats) Connection thread R Model Effective area (2) mm2 Applicable tubing O.D.

KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.

(Including Bracket, Screw, Set Screw) Applicable bore size (mm) Cylinder series C96 32 BT-03 40 BT-03 50 BT-05 63 BT-05 80 BT-06 100 BT-06 125 BT-08 The following stainless steel mounting screw kit (including set screws) is available. Use it in accordance with the operating environment. (Since the auto switch mounting bracket is not included, order it separately.)

PD ) 4 -46 4.4.1 Parameter list 4 -46 4.4.2 List of details 4 47 4.4.3 Using forward/reverse rotation stroke end to change the stopping pattern 4 58 5.

VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 31 32 33 34 35 36 37 38 41 42 43 44 45 46 47 48 49 50 51 52 300 mm Note