D-side How to order applicable valves VQC 4 0 5 E B 0 Y 1 Series VQC4000 F E D A C B Stations are numbered in ascending order from the D-side.
(Note5) Circulating fluid temperature: CH1: 20C/CH2: 25C at the device outlet. (Note6) Flow rate required to maintain cooling capacity.Install bypass piping if the flow rate is less than the minimum required flow rate. (Note7) Front 1m/Height 1m.
(mm) Effective area Note 2) (mm2) Note 1) L M Weight (g) Model D 2 x applicable tubing 4 6 8 10 12 KQGH04-00 KQGH06-00 KQGH08-00 KQGH10-00 KQGH12-00 11 37 18 16 5.6 D D 13 38 18.5 22 13.1 M M 15 42.8 20.9 31 26.1 L 19 47 23 54 41.5 21 50.6 24.8 66 58.3 Note 1) D is maximum diameter.
VQ7 C4 C6 VZ3000-50A-1Manifold block assembly q (a) Bolt (Both sides) EVS For D side, With D-sub connector and P/R port with One-touch fitting for 8 SUP/EXH block assembly VZ3000-51A-1D w D side For U side, With D-sub connector and P/R port with One-touch fitting for 8 For D side, set with w VFN SUP/EXH block assembly VZ3000-51A-1U e DIN rail End block assembly VZ3000-52A-2D r VZ3000-52A-
If the mounted valve is N.O., apply pressure to the 3(E) port and exhaust air from the 1(P) port. 4 Series VV100 3 Port Solenoid Valve/D-sub Connector Connector Type Manifold Plug-in How to Order Valve for Connector Type Standard V1 1 U 0 C4 T D 5 C D 1 C Z J 0 C4 5 With switch V1 Individual wiring [For plug-in mixed mounting] T D Note) See page 13 for the dedicated non plug-in individual
Note Manifold block assembly C6: A, B port with One-touch fitting for 6 C8: A, B port with One-touch fitting for 8 C6 C8 VQ7 VZ5000-50A-1q (a) Bolt (Both sides) For D side, With D-sub connector and P/R port with One-touch fitting for 10 For U side, With D-sub connector and P/R port with One-touch fitting for 10 SUP/EXH block assembly VZ5000-51A-1D w EVS D side SUP/EXH block assembly End block
LEF D-M9NAV D-M9NA D-M9BA D-M9BAV D-M9PAV D-M9PA Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction LEJ 3-wire 2-wire Wiring type NPN PNP Output type LEL 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage LEM 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage
Note 3) Bowl assembly for the AL30 to AL60 models comes with a bowl guard (steel band material). 511 Series AL10 to AL60 Dimensions AL10 AL20 J M U T N S D Bracket (Option) A B C R B C Q IN OUT IN OUT OUT 2 x P (Port size) OUT 2 x P (Port size) Clearance for maintenance G Clearance for maintenance A G AL30, AL40 AL50, AL60 Bracket (Option) T N S T M U M U D J D J N S Bracket (Option) R B
(kg) Applicable dryer Port size NPT A B C D E D E Part no.
E) High temperature oil (3) (S) (D) 99 100 183 AC DC AC DC 60 40 80 60 60 40 40 60 Maximum Minimum 1 10 (1) 10 5 (2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E etc. in parentheses are option symbols.
operating pressure (at 20C) 1.0 MPa KK Refer to the withstand pressure and heat resistance performance data.
Printed in Japan. 1st printing May, 2000 D-SMC.L.A. P-80 (D)
VC VDW Option Symbol and Composition Fluid Name and Option Body, Shading coil material Option symbol Seal material Coil insulation type VQ Fluid (Application) Option symbol Standard A D NBR FKM FKM Heated water (up to 80C) D B VX2 H BC6, Copper Fuel oil (up to 60C) A Fuel oil (up to 80C) D VX If using for other fluids, please contact SMC. VX3 VXA VN Normally Open (N.C.)
E) High temperature oil (3) (S) (D) 99 100 183 AC DC AC DC 60 40 80 60 60 40 40 60 Maximum Minimum 1 10 5 (2) 10 (1) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E etc. in parentheses are option symbols.
B IDFB4E to 15E A Power cable outlet 0.7 [17 mm] Grommet with membrane Signal cable outlet 0.7 [17 mm] Terminal block (Wire diameter 0.4 [9 to 11mm]) Grommet with membrane Power cable outlet 0.7 [17 mm] IDFB4E to 11E_Terminal block C D A B Terminal block Dimensions Unit: inch [mm] A B C D Model B B 9.0 [230] 2.6 [67] 7.0 [179] 1.3 [32] IDFB4E, 6E, 8E, 11E A Power cable outlet 0.7 [17 mm]
Fluid JIS Symbol Standard specifications Option (1) Made to Order (2) OUT Water (standard) Turbine oil High temperature water (D, E, N, P) High temperature oil (D, N) Air X44 Note 1) Refer to page 17-3-9 Applicable Fluids Check List for details of special fluids outside of the standard options and specifications. Note 2) Please contact SMC for details.
Fluid JIS Symbol Standard specifications Option Note ) OUT Water (Standard, up to 60C) Turbine oil High temperature water (D) High temperature oil (D) Note) Refer to page 17-3-11 Applicable Fluids Check List for details of special fluids outside of the standard options and specifications.
) (Mounting hole pitch) MAX. 11 VZ3540 (Mounting hole pitch) (Lead wire length) G: 300 mm H: 600 mm 2-M5 x 0.8 (PE port) 4-Rc 1/8 (Piping port) L plug connector (L) VZ3 40-L-01 M plug connector (M) VZ3 40-M-01 3 4 5 3 4 5 (Lead wire length) 300 300 (Lead wire length) : With light/surge voltage suppressor Built-in speed controllers VZ3 50DIN terminal (D) VZ3 40-D-01 3 4 5 3 4 5 Applicable