SMC Corporation of America
Elite Part Number Search
Search Results "SS3YJ3-41-09-M3"

Example) AM30-N03BD-6RZ-D q e r t y w Symbol Description w Body size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type

Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth

53-SS5Y5-41-05-01 1 set (Type 41, 5 station manifold base part no.) 53-SY5240-LL3 2 sets (Double solenoid part no.) 53-SY5140-LL3 2 sets (Single solenoid part no.)

Dimensions (mm) Recommended flow m3/min (ANR) Model Port size R Effective area (mm2) Weight (g) A B C 1 8 ANB1-02 15 10 51 22 ANB1-01 22 81 25 18 35 93 30 21 94 107 46 24 175 133 50 41 462 190 74 41 612 230 74 60 871 271 86 70 1.2 or less 2.7 or less 3.8 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 1 4 ANB1-03 35 3 8 ANB1-04 60 1 2 ANB1-06 90 3 4 ANB1-10 160 1

IDFB4E to 15E AT 1.6 [40] IDF IDU Air Flow Capacity 2.36 [60] Model IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFA D Circuit breaker 5 SCFM (8 m3/h) 13 SCFM (23 m3/h) 17 SCFM (29 m3/h) 19 SCFM (32 m3/h) 23 SCFM (39 m3/h) Air flow capacity (ANR) IDFB IDFB A Conditions: Inlet air pressure: 100 psi (0.7 MPa), Inlet air temperature: 100F (37.8C), Outlet air temperature: 50F (10C), Ambient temperature

(Tightening torque of M3 screw: 0.5 to 0.7 Nm) 8.

Pass the auto switch mounting screw (M3) supplied with the auto switch mounting band from the through-hole side of the auto switch mounting band and engage it with the M3 female thread of the auto switch mounting band through the through-hole in the switch bracket. 5. Tighten the auto switch mounting screw with the specified tightening torque (0.6 to 0.7 Nm). 6.

mounting nut Hexagon socket head cap bolt (M3 x 0.5 x 14 spring wasdher 2 pcs.)

TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0

This could cause an auto switch malfunction. 8 6.5 N x M3 x 0.5 thread depth 4.5 Note 1) Note 2) Retraction end adjuster Extension end adjuster 3 depth 3 +0.03 0 22.5 (Extension end adjuster) 3.5 6.5 4 0.7 6.5 (Extension end adjuster) 0.3 22.2 15 17 36 24 16 32 1 12 16 F 3 depth 3 +0.03 0 5 4 x M3 x 0.5 thread depth 4 2 N 1 x F 10 30 3 x M4 x 0.7 thread depth 6 M 24 14.6 KA NA x M3 x 0.5

41 50 59.5 59.5 66 96 36 48 38 44 44 57.5 57.5 57.5 71.5 71.5 86 107 107 102 144 13 17 17 22 22 22 27 27 32 41 41 41 55 0.09 0.18 0.18 0.36 0.36 0.36 0.61 0.61 1.09 2.03 2.03 4.1 10 7 8 8 11 11 11 13.5 13.5 16 20 20 20 24 6.6 9 9 11 11 11 11 11 14 16 16 14 22 24.5 28.5 28.5 35.5 35.5 35.5 44.5 44.5 53 65 65 56 78 1148 JA Series Made to Order: Individual Specifications Please contact SMC

= 38.7 (Nm) M3 = m3 x g x X = 6.525 x 9.8 x 138.5 x 103 = 8.86 (Nm) MTS m3 M3 Load factor 3 = M3/M3max = 8.86/38.7 = 0.23 MY 5.

x 10-3 = 2.81 (Nm) Load factor 2 = M2/M2 max = 2.81/50 = 0.06 m3 M2 9 Model Selection Series MY2 Calculation of Guide Load Factors X M3: Moment M3 max (from 3 of graph MY2H/M3) = 60 (Nm) M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 Load factor 3 = M3/M3 max = 10.33/60 = 0.17 5 Calculation of load factor for dynamic moment Z Equivalent load FE at impact 1.4 100 1.4 100

Load factor 1 = m3 / m3 max = 7.025 / 22.5 = 0.31 m3 M2: Moment Z M2 max (from 2 of graph MY2H / M2) = 19.5 (Nm) . M2 = m3 x g x Z = 7.025 x 9.8 x 37.8 x 103 = 2.60 (Nm) Load factor 2 = M2 / M2 max = 2.60 / 19.5 = 0.13 m3 M2 5 Series E-MY2 Selection Example cont. X M3: Moment M3 max (from 3 of graph MY2H / M3) = 19.5 (Nm) .

Dimensions Note) A B 29 33 41 D 67 81 93 C 40 52 63 VQZ1000 VQZ2000 VQZ3000 35 43 52 A Note) For grommet Individual EXH spacer VVQZ1000-R-5-M5 (VQZ1000) VVQZ2000-R-5-01 (VQZ2000) VVQZ3000-R-5-02 (VQZ3000) M5: VQZ1000 Rc 1/8: VQZ2000 Rc 1/4: VQZ3000 Exhaust port can be installed individually by mounting an individual exhaust spacer on to the manifold block.

LC6D-507AD-Q (Refer to page 306 for details.) 0.05mm Holding plate: MB1 (1 pc.), Phillips countersunk head screw: M3 x 6l (1 pc.) Phillips binding head screw: M3 x 4l (2 pcs.), Toothed lock washer M3 (2 pcs.) Binding band: T18S (1 pc.)

52 70 83 G 41 63 68 72 98 H J K P.C.D L1 6-6.6 8-8.4 L2 XMD-25 XMD-40 XMD-50 XMD-63 XMD-80 50 65 70 88 90 16 20 20 20 20 7.5 15 17.5 19.5 26.5 P.C.D 58.7 P.C.D 92.1 C D XYD/In-line type G Fd C (K flange) J K H B S M 45 A Fn (KF flange) E K (mm) Model A 86.7 114 128 163 193 B 48 66 79 100 117 C 1 2 2 3 3 D 23.5 38 53 61 80 E 40 55 75 87 114 Fn 95 110 Fd 26 41 52 70 83 G 66 84 95 121

5.9 11 11 14 19 E M3 x 0.5 Finger opening port M3 x 0.5 0 -0.1 2-2.6 through (Mounting hole) 17 12 12 Finger closing port 2-4.5 0.8 0.8 E-E +0.1 0 Close: 0 Open: 81 Use the attached hexagon socket head screws for mounting holes. 4-M3 x 0.5 thread depth 4 14 Mounting thread 4-M2.5 x 0.45 thread depth 3 Attachment mounting thread Groove for auto switch mounting M2.5 x 0.45 4 1.3 12 26 4 15

1) Remove the dust cover. 2) Supply air pressure of 0.2MPa or more to the unlocking port, and set the lock ring to the perpendicular position. 3) Screw the unlocking bolt which is included (hexagon socket head cap screw/20, 25: M3 x 5l, 32: M3 x 10l) into the lock ring to hold the unlocked condition. Unlocking bolt Unlocking port Dust cover 2.

mounting attachment) M3 x 0.5 (Finger closing port) Auto switch mounting groove (2 positions) Adjustment needle for finger speed 11.6 3 9.4 S 4 6 0 0.05 4 7 7 Note) For single acting, one port is used as a breather port. 2.3 17.5 M3 x 0.5 (Finger opening port) MHKL2-12: Long stroke type 9 2-M3 x 0.5 thread depth 5 (Mounting thread) 20 3H9 depth 3 +0.025 0 13H9 depth 1.5 +0.043 0 2-M3 x 0.5