(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 460 920 790 1580 100 180 230 390 Flow rate (l/min (ANR)) Controlled (free) flow 7 14 12 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.
(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.
Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.
Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the (ANR) after the unit depicting air volume.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C, it is 2.8 x 10-8 sec, or about 200 times shorter. The objective of baking is to exhaust water with long adsorption residence time more quickly. XVD Surface leakage This leakage occurs between surfaces of the sealing and the seal material.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C, it is 2.8 x 10-8 sec, or about 200 times shorter. The objective of baking is to exhaust water with long adsorption residence time more quickly. XVD Surface leakage This leakage occurs between surfaces of the sealing and the seal material.
(Variation: 10%) *7 The value when there is an ambient temperature of 20C and when the rated voltage is applied. The value depends on the ambient environment.
In-line Air Filter RoHS Operating pressure range 100 kPa to 1.0 MPa (20C) Both positive pressure and vacuum pressure can be used with one unit! 5 m Filtration OUT IN 100 kPa 1.0 MPa Positive pressure e.g.)
Standard equipment AMF 1/2B 3/8B 1B (3) Accessory 11/2B SF Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) Based on discharge rate and discharge temperature (70C) of screw type compressors. Note 3) The accessories should be mounted by user.
At this time correction factor line becomes A . coefficient (1) To get correction factor of 1.35 use ambient temperature correction factor A at 20C. (2) (3) To get outlet air temperature divide 38.5C from (1) by 1.35 from (2).
Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.
(at 20C) Data 10-12-9 9 Series CEP1 Proper Auto Switch Mounting Position Weight (Without mounting bracket/connector) (kg) Regarding dimensions for the proper auto switch mounting position (at stroke end), refer to page 1012-16.
Piston rod Table (2) MXP6 MXP10/12/16 L2 L2 L2 (mm) 10 (One side only) 10 (One side only) 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Damage is not allowed. 3. Shock absorber is considered a consumable component. When energy absorption is decreased, replace it.
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 15 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 13 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 17 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 18 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 7 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 2 Stations
Port Size: M01 [Body Ported Stacking (Barb Fitting:ø6/ø4, Tubing:ø3.18/ø2)], Stations: 3 Stations